LabMedica

Download Mobile App
Recent News Expo Clinical Chem. Molecular Diagnostics Hematology Immunology Microbiology Pathology Technology Industry Focus

Breath Ammonia Biomarker Predicts Kidney Function in CKD Patients

By LabMedica International staff writers
Posted on 18 Nov 2020
Print article
Image: The Ammonia Breath test: the sensing system included a desiccation cylinder, an airtight sensing chamber, a rotameter, a pump, and an electrical signal measurement instrument (Photo courtesy of Chang Gung University).
Image: The Ammonia Breath test: the sensing system included a desiccation cylinder, an airtight sensing chamber, a rotameter, a pump, and an electrical signal measurement instrument (Photo courtesy of Chang Gung University).
Chronic kidney disease (CKD) is a type of kidney disease in which there is gradual loss of kidney function over a period of months to years. Initially there are generally no symptoms; later, symptoms may include leg swelling, feeling tired, vomiting, loss of appetite, and confusion.

Diagnosis of CKD is largely based on history, examination and urine dipstick combined with the measurement of the serum creatinine level. It is important to differentiate CKD from acute kidney injury (AKI) because AKI can be reversible. One diagnostic clue that helps differentiate CKD from AKI is a gradual rise in serum creatinine (over several months or years) as opposed to a sudden increase in the serum creatinine (several days to weeks).

Nephrologists at the Chang Gung Kidney Research Center (Taoyan, Taiwan) and their colleagues investigated whether exhaled breath ammonia measurement could be used for rapid CKD screening. The scientists enrolled 121 patients with CKD stages 1 to 5 (average age, 61 years; 62 patients were men) and compared breath ammonia level measurements with blood urea nitrogen (BUN), creatine and eGFR levels. The gas measurement system used in this study was composed of a rotameter, pump, desiccation cylinder, the sensing chamber, and an electrical signal measurement instrument (Keysight Technologies, Santa Rosa, CA, USA).

The team reported that breath ammonia level correlated with BUN, serum creatinine, eGFR and inversed eGFR levels. Breath ammonia concentration was increasingly elevated at each stage of CKD (stage 1: 636 ± 94 ppb; stage 2: 1,020 ± 326 ppb; stage 3: 1,943 ± 326 ppb; stage 4: 4,421 ± 1,042 ppb; stage 5: 12,781 ± 1,807 ppb). The area under curve for a breath ammonia level cutoff concentration of 1,187 ppb comparing patients with eGFR of at least 60 mL/min/1.73 m2 with patients with eGFR of no more than 60 mL/min/1.73 m2 was 0.831 (positive predictive value, 0.84; negative predictive value, 0.61; sensitivity, 71%; specificity, 78%).

The scientists noted that at 886 ppb, the sensitivity increased to 80%, but the specificity decreased to 69%. They also wrote there were no significant differences between patients in each stage regarding sex, body weight, hemoglobin, albumin, comorbidities and medication and that BUN level, creatinine and eGFR increased with each CKD stage.

Ya-chung Tian, MD, an associate professor of nephrology and a co-author of the study, said, “Because CKD is non-life threating and breath ammonia detection was conducted in real time, inexpensive, easy to administer and had an acceptable diagnostic accuracy, breath ammonia can be used as a good surrogate for kidney function and a reliable tool for CKD screening.”

The authors concluded that breath ammonia detection with vertical-channel organic semiconductor (V-OSC) is a real time, inexpensive, and easy to administer measurement device for screening CKD with reliable diagnostic accuracy. The study was published on October 31, 2020 in the journal Biomedical Materials and Nanomedicine.

Related Links:
Chang Gung Kidney Research Center
Keysight Technologies


Platinum Member
COVID-19 Rapid Test
OSOM COVID-19 Antigen Rapid Test
Magnetic Bead Separation Modules
MAG and HEATMAG
Complement 3 (C3) Test
GPP-100 C3 Kit
New
Gold Member
Liquid Ready-To-Use Lp(a) Reagent
Lipoprotein (a) Reagent

Print article

Channels

Hematology

view channel
Image: The CAPILLARYS 3 DBS devices have received U.S. FDA 510(k) clearance (Photo courtesy of Sebia)

Next Generation Instrument Screens for Hemoglobin Disorders in Newborns

Hemoglobinopathies, the most widespread inherited conditions globally, affect about 7% of the population as carriers, with 2.7% of newborns being born with these conditions. The spectrum of clinical manifestations... Read more

Immunology

view channel
Image: The AI predictive model identifies the most potent cancer killing immune cells for use in immunotherapies (Photo courtesy of Shutterstock)

AI Predicts Tumor-Killing Cells with High Accuracy

Cellular immunotherapy involves extracting immune cells from a patient's tumor, potentially enhancing their cancer-fighting capabilities through engineering, and then expanding and reintroducing them into the body.... Read more

Microbiology

view channel
Image: The T-SPOT.TB test is now paired with the Auto-Pure 2400 liquid handling platform for accurate TB testing (Photo courtesy of Shutterstock)

Integrated Solution Ushers New Era of Automated Tuberculosis Testing

Tuberculosis (TB) is responsible for 1.3 million deaths every year, positioning it as one of the top killers globally due to a single infectious agent. In 2022, around 10.6 million people were diagnosed... Read more