LabMedica

Download Mobile App
Recent News Expo Clinical Chem. Molecular Diagnostics Hematology Immunology Microbiology Pathology Technology Industry Focus

Two Vitamin D Immunoassays Compared

By LabMedica International staff writers
Posted on 20 Aug 2019
Print article
Image: The Architect 25-OH Vitamin D reagent kit (Photo courtesy of Abbott).
Image: The Architect 25-OH Vitamin D reagent kit (Photo courtesy of Abbott).
Vitamin D can be synthesized in skin from 7-dehydrocholesterol following ultraviolet light exposure, which produces Vitamin D3 (cholecalciferol). Vitamin D2 (ergocalciferol) is present in plant sources, and can be absorbed from the diet.

Measurement of 25-Hydroxyvitamin D (25-OH-D) is commonly performed to assess Vitamin D status in clinical laboratories; however, the ability of these assays to detect Vitamin D2 (as 25-OH-D2) or Vitamin D3 (as 25-OH-D3) varies. Assessment of Vitamin D status by measurement of 25-Hydroxyvitamin D (25-OH-D) is widely performed by immunoassay.

Biochemists at Baylor College of Medicine (Houston, TX, USA) and their colleagues evaluated the performance of the institution's total 25-OH-D assay on the Architect i1000 SR platform to detect either 25-OH-D2 or 25-OH-D3. This assay is a chemiluminescent microparticle immunoassay. Samples spiked with either 25-OH-D2 or 25-OH-D3 and reference laboratory samples with either 25-OH-D2 or 25-OH-D3 concentrations determined by liquid chromatography-tandem mass spectrometry (LC-MS/MS) were used for evaluation. As a comparison to the Architect assay, samples were also tested on the Cobas 8000, which uses an electrochemiluminescence binding assay.

The scientists reported that recovery of 25-OH-D3 in spiked samples was similar by Architect (84%–87%) and Cobas (90%). Recovery of 25-OH-D2 was lower than 25-OH-D3, and was poorer by Architect (37%–40%) than by Cobas (69%–71%). In measurement of samples with known 25-OH-D concentrations, performance of Architect and Cobas assays was similar for 25-OH-D3. However, at concentrations greater than 50 nmol/L 25-OH-D2, the Architect assay exhibited large average negative bias of −27%.

The authors concluded that while the Architect and Cobas assays performed similarly in detection of 25-OH-D3, the Architect assay was significantly poorer at detecting 25-OH-D2 than Cobas, with poorer recovery and significant negative bias at higher concentrations of 25-OH-D2. This agrees with other studies, and indicates that caution should be used in interpreting Architect 25-OH-D results in patients supplemented with Vitamin D2. The study was published on July 29, 2019, in the journal Practical Laboratory Medicine.

Platinum Member
COVID-19 Rapid Test
OSOM COVID-19 Antigen Rapid Test
Magnetic Bead Separation Modules
MAG and HEATMAG
Complement 3 (C3) Test
GPP-100 C3 Kit
Gold Member
Systemic Autoimmune Testing Assay
BioPlex 2200 ANA Screen with MDSS

Print article

Channels

Hematology

view channel
Image: The CAPILLARYS 3 DBS devices have received U.S. FDA 510(k) clearance (Photo courtesy of Sebia)

Next Generation Instrument Screens for Hemoglobin Disorders in Newborns

Hemoglobinopathies, the most widespread inherited conditions globally, affect about 7% of the population as carriers, with 2.7% of newborns being born with these conditions. The spectrum of clinical manifestations... Read more

Immunology

view channel
Image: The AI predictive model identifies the most potent cancer killing immune cells for use in immunotherapies (Photo courtesy of Shutterstock)

AI Predicts Tumor-Killing Cells with High Accuracy

Cellular immunotherapy involves extracting immune cells from a patient's tumor, potentially enhancing their cancer-fighting capabilities through engineering, and then expanding and reintroducing them into the body.... Read more

Microbiology

view channel
Image: The T-SPOT.TB test is now paired with the Auto-Pure 2400 liquid handling platform for accurate TB testing (Photo courtesy of Shutterstock)

Integrated Solution Ushers New Era of Automated Tuberculosis Testing

Tuberculosis (TB) is responsible for 1.3 million deaths every year, positioning it as one of the top killers globally due to a single infectious agent. In 2022, around 10.6 million people were diagnosed... Read more