Samples Quality Improved Using Low-Vacuum Tubes

By LabMedica International staff writers
Posted on 16 Jul 2019
Print article
Image: The BD Barricor tube is a single-use, plastic evacuated tube with a mechanical separator used to collect, separate, transport and process venous blood specimens (Photo courtesy of Becton, Dickinson and Company).
Image: The BD Barricor tube is a single-use, plastic evacuated tube with a mechanical separator used to collect, separate, transport and process venous blood specimens (Photo courtesy of Becton, Dickinson and Company).
Centrifugation is a time consuming step, which contributes to increase the turnaround time (TAT) in laboratories, likewise hemolyzed samples that needs a re-sampling could delay management of patients.

So, the absence of hemolysis is one of the most important quality indicators for biochemistry as many analytes are influenced at the up or at the down with sample hemolysis. The hemolysis index is a measurement of the red color of serum. This color is normally due almost exclusively to the presence of hemoglobin, which comes from ruptured red blood cell membranes.

Medical biochemists and their colleagues at the Lapeyronie University Hospital (Montpellier, France) evaluated the impact of replacing BD vacutainer heparin lithium tube by low-vacuum BD Vacutainer Barricor tube in an emergency department (ED) on hemolysis rate and TAT. In the first phase blood tests for biochemistry were all performed using 4 mL plastic BD Vacutainer lithium heparin tubes and tubes were then centrifuged during 15 minutes  at 2,000g in an emergency dedicated Multifuge X3 FR Centrifuge.

After this first period, all 4 mL BD Vacutainer lithium heparin tubes were removed from the ED and replaced by 3.5 mL BD Vacutainer Barricor lithium heparin tubes during the one day of transition. Hemolysis Index (HI) was measured in the conventional unit (free hemoglobin mg/dL) on all tubes using the Cobas 8000 Roche test SSI-2 on a c701 module. Eight chemistry analytes were measured on the four different Cobas 8000 modules.

The scientists reported that a significantly reduced time duration between reception of sample and available results in informatics laboratory system was observed with the reduction time of centrifugation allowed by use of Barricor tube compared to regular heparin lithium tubes. A statistical significant decrease in hemolysis rate also occurred in the second period as samples with HI  less than 10 reached from 52.5% in the first period to 68.5% in the second.

The authors concluded that their study highlighted two advantages when using low-vacuum Barricor tubes which was a reduction of centrifugation time allowing improvement of laboratory TAT and a reduction of hemolyzed samples that improve sample and result quality. The study was published on June 12, 2019, in the journal Practical Laboratory Medicine.

Related Links:
Lapeyronie University Hospital

Platinum Member
COVID-19 Rapid Test
OSOM COVID-19 Antigen Rapid Test
Magnetic Bead Separation Modules
MAG and HEATMAG
Anti-Cyclic Citrullinated Peptide Test
GPP-100 Anti-CCP Kit
New
Gold Member
Magnetic Bead Separation Modules
MAG and HEATMAG

Print article

Channels

Hematology

view channel
Image: The CAPILLARYS 3 DBS devices have received U.S. FDA 510(k) clearance (Photo courtesy of Sebia)

Next Generation Instrument Screens for Hemoglobin Disorders in Newborns

Hemoglobinopathies, the most widespread inherited conditions globally, affect about 7% of the population as carriers, with 2.7% of newborns being born with these conditions. The spectrum of clinical manifestations... Read more

Immunology

view channel
Image: The AI predictive model identifies the most potent cancer killing immune cells for use in immunotherapies (Photo courtesy of Shutterstock)

AI Predicts Tumor-Killing Cells with High Accuracy

Cellular immunotherapy involves extracting immune cells from a patient's tumor, potentially enhancing their cancer-fighting capabilities through engineering, and then expanding and reintroducing them into the body.... Read more

Microbiology

view channel
Image: The T-SPOT.TB test is now paired with the Auto-Pure 2400 liquid handling platform for accurate TB testing (Photo courtesy of Shutterstock)

Integrated Solution Ushers New Era of Automated Tuberculosis Testing

Tuberculosis (TB) is responsible for 1.3 million deaths every year, positioning it as one of the top killers globally due to a single infectious agent. In 2022, around 10.6 million people were diagnosed... Read more