LabMedica

Download Mobile App
Recent News Expo Clinical Chem. Molecular Diagnostics Hematology Immunology Microbiology Pathology Technology Industry Focus

Confirmation Testing for Primary Hyperaldosteronism Remains Essential

By LabMedica International staff writers
Posted on 10 Jul 2019
Print article
Primary aldosteronism, also known as primary hyperaldosteronism (PHA) or Conn's syndrome, refers to the excess production of the hormone aldosterone from the adrenal glands, resulting in low renin levels. This abnormality is caused by hyperplasia or tumors.

Primary hyperaldosteronism is among the most common causes of secondary hypertension, with a prevalence of ~4.3% in patients with hypertension. Many suffer from fatigue, potassium deficiency and high blood pressure, which may cause poor vision, confusion or headaches. Symptoms may also include: muscular aches and weakness, muscle spasms, low back and flank pain from the kidneys, trembling, tingling sensations, numbness and excessive urination.

Scientists working with the University Hospital Olomouc and Palacký University (Olomouc, Czech Republic) performed confirmatory testing on 312 ambulatory patients with severe or resistant arterial hypertension who had an aldosterone-to-renin ratio (ARR) of >30 or aldosterone levels of >150 ng/L. The confirmatory testing was performed with identical laboratory examinations before and after infusion of saline for four hours and after withdrawal of potentially interfering medications.

Patients with confirmed PHA were more likely to be men (70.3% versus 54.9%), had lower serum potassium (3.8 versus 4.1 mmol/L) and plasma renin activity (0.7 versus 3.2), higher serum aldosterone (268 versus 229 ng/L) and ARR (177 versus 95), higher office systolic blood pressure (147 versus 143 mmHg). Significant predictors of PHA were plasma renin assay (PRA) < 0.63 (AUC ROC 0.63), aldosterone >165 ng/L (AUC 0.60), ARR > 43 (AUC 0.68), serum potassium <4.0 mmol/L (AUC 0.68) and the number of used antihypertensive drugs >4 (AUC 0.64).

When applied to the cohort, combined recommended cut-off values determined by international guidelines that further testing was not needed (aldosterone >200 ng/L and potassium <4.0 mmol/L) had an overall accuracy for diagnosis of primary hyperaldosteronism of only 69.0%. A combination of ARR >43 and serum potassium <4 mmol/L had overall accuracy for primary hyperaldosteronism of 75.6%.

Jan Vaclavik, MD, the senior author of study, said, “These results show the prediction of the diagnosis of primary hyperaldosteronism from the results of screening tests is not entirely accurate. Conduction of confirmatory tests is therefore required in all patients with a positive screening test.” The study was presented at the 29th Scientific Meeting of the European Society of Hypertension held June 21-24, 2019, in Milan, Italy.

Related Links:
University Hospital Olomouc and Palacký University

Platinum Member
COVID-19 Rapid Test
OSOM COVID-19 Antigen Rapid Test
Magnetic Bead Separation Modules
MAG and HEATMAG
Complement 3 (C3) Test
GPP-100 C3 Kit
New
Gold Member
TORCH Panel Rapid Test
Rapid TORCH Panel Test

Print article

Channels

Hematology

view channel
Image: The CAPILLARYS 3 DBS devices have received U.S. FDA 510(k) clearance (Photo courtesy of Sebia)

Next Generation Instrument Screens for Hemoglobin Disorders in Newborns

Hemoglobinopathies, the most widespread inherited conditions globally, affect about 7% of the population as carriers, with 2.7% of newborns being born with these conditions. The spectrum of clinical manifestations... Read more

Immunology

view channel
Image: The AI predictive model identifies the most potent cancer killing immune cells for use in immunotherapies (Photo courtesy of Shutterstock)

AI Predicts Tumor-Killing Cells with High Accuracy

Cellular immunotherapy involves extracting immune cells from a patient's tumor, potentially enhancing their cancer-fighting capabilities through engineering, and then expanding and reintroducing them into the body.... Read more

Microbiology

view channel
Image: The T-SPOT.TB test is now paired with the Auto-Pure 2400 liquid handling platform for accurate TB testing (Photo courtesy of Shutterstock)

Integrated Solution Ushers New Era of Automated Tuberculosis Testing

Tuberculosis (TB) is responsible for 1.3 million deaths every year, positioning it as one of the top killers globally due to a single infectious agent. In 2022, around 10.6 million people were diagnosed... Read more