We use cookies to understand how you use our site and to improve your experience. This includes personalizing content and advertising. To learn more, click here. By continuing to use our site, you accept our use of cookies. Cookie Policy.

LabMedica

Download Mobile App
Recent News Expo Clinical Chem. Molecular Diagnostics Hematology Immunology Microbiology Pathology Technology Industry Focus

Molecular Test Detects Three Arboviruses in Plasma Samples

By LabMedica International staff writers
Posted on 04 Aug 2016
Print article
Image: A digitally colorized transmission electron micrograph (TEM) of Zika virus. Viral particles are 40 nm in diameter with an outer envelope and dense inner core (Photo courtesy of Cynthia Goldsmith / CDC).
Image: A digitally colorized transmission electron micrograph (TEM) of Zika virus. Viral particles are 40 nm in diameter with an outer envelope and dense inner core (Photo courtesy of Cynthia Goldsmith / CDC).
Currently, multiple arboviruses are circulating in Brazil: Zika, chikungunya and dengue and they have similar clinical pictures, which can lead to misdiagnosis based on clinical grounds alone.

Detection tests for viral ribonucleic acid (RNA) such as the quantitative reverse transcription polymerase chain reaction (RT-qPCR) can reliably and specifically distinguish the three viruses and the specific diagnosis can be important in anticipating, preventing, and managing complications.

Scientists at the Laboratório Sabin (Brasília, Brazil) and their colleagues collected 90 plasma samples from the routine arbovirus laboratory, 20 positive for Zika (RT-qPCR), six positive for chikungunya (RT-qPCR), 18 positive for dengue nonstructural protein 1 antigen test (NS-1) and 46 negative for all three viruses. Nucleic acids were extracted from 1mL of sample by using an automated DNA extractor. An in-vitro transcribed random RNA sequence, which is not found in the nature, was spiked into plasmas during the nucleic acids extraction to function as a process control. Primers/probes for chikungunya were specifically designed for this study.

Zika, chikungunya and dengue viruses were assessed simultaneously by RT-qPCR, but in independent reaction wells. The control RNA was co-amplified in all instances. The viral loads of specific samples were quantified against a serial dilution of synthetic single-stranded DNA (ssDNA) and the limits of detection of each assay were determined by probit regression analysis. To investigate the precision of the assays, three samples at ~72, ~7.2 and ~0.72 copies/mL of each viruses were evaluated by using the Clinical and Laboratory Standards Institute (CLSI) EP12-A2 method during five days in quadruplicate by two operators.

The investigators reported that the limits of detection were 26 copies/mL for Zika, 23.5 copies/mL, for chikungunya and 25.6 copies/mL for dengue. The ~72, ~7.2 and ~0.72 copies/mL samples yielded 18/20 (90%), 2/20 (10%) and 1/20 (5%) positive results for Zika, 18/20 (90%), 4/20 (20%) and 0/20 (0%) positive results for chikungunya and 20/20 (100%), 16/20 (80%) and 0/20 (0%) positive results for dengue, respectively. The total, positive and negative agreements between compared methods were 95.5%, 90% and 97.5 for Zika, 100% for all methods for chikungunya and 95.6%, 100% and 94.5%, for dengue, respectively. No cross-reaction was observed.

The authors concluded that the RT-PCR method for simultaneous detection of Zika, chikungunya and dengue viruses is highly sensitive, all assays showed limit of detection below 50 copies/mL. Moreover, cut-off regions were characterized and acceptable precisions were observed for positive (~72 copies/mL and above) and negative (~0.72 copies/mL and below) results. Finally, the agreements with the comparative methods were very good, above 90% of concordance in all instances. The study was presented at the 68th American Association of Clinical Chemistry (AACC) Annual Scientific Meeting held July 31 to August 4, 2016, in Philadelphia, PA, USA.

Related Links:
Laboratório Sabin
American Association of Clinical Chemistry
Platinum Member
COVID-19 Rapid Test
OSOM COVID-19 Antigen Rapid Test
Magnetic Bead Separation Modules
MAG and HEATMAG
POCT Fluorescent Immunoassay Analyzer
FIA Go
New
Gold Member
Plasma Control
Plasma Control Level 1

Print article

Channels

Clinical Chemistry

view channel
Image: The 3D printed miniature ionizer is a key component of a mass spectrometer (Photo courtesy of MIT)

3D Printed Point-Of-Care Mass Spectrometer Outperforms State-Of-The-Art Models

Mass spectrometry is a precise technique for identifying the chemical components of a sample and has significant potential for monitoring chronic illness health states, such as measuring hormone levels... Read more

Molecular Diagnostics

view channel
Image: Researchers have found a way to spot the debilitating disease Alzheimer\'s before it develops into dementia (Photo courtesy of 123RF)

Advanced Blood Test to Spot Alzheimer's Before Progression to Dementia

Alzheimer’s disease is well known for its slow development over many years, which typically leads to treatment interventions only after the disease has advanced to stages where it may be nearly impossible... Read more

Hematology

view channel
Image: The CAPILLARYS 3 DBS devices have received U.S. FDA 510(k) clearance (Photo courtesy of Sebia)

Next Generation Instrument Screens for Hemoglobin Disorders in Newborns

Hemoglobinopathies, the most widespread inherited conditions globally, affect about 7% of the population as carriers, with 2.7% of newborns being born with these conditions. The spectrum of clinical manifestations... Read more

Immunology

view channel
Image: Exosomes can be a promising biomarker for cellular rejection after organ transplant (Photo courtesy of Nicolas Primola/Shutterstock)

Diagnostic Blood Test for Cellular Rejection after Organ Transplant Could Replace Surgical Biopsies

Transplanted organs constantly face the risk of being rejected by the recipient's immune system which differentiates self from non-self using T cells and B cells. T cells are commonly associated with acute... Read more

Microbiology

view channel
Image: The ASTar System has received US FDA 510(k) clearance (Photo courtesy of Q-linea AB)

Automated Sepsis Test System Enables Rapid Diagnosis for Patients with Severe Bloodstream Infections

Sepsis affects up to 50 million people globally each year, with bacteraemia, formerly known as blood poisoning, being a major cause. In the United States alone, approximately two million individuals are... Read more

Pathology

view channel
Image: The new method is quick and easy, and can also be used by non-medical personnel. (Photo courtesy of Zoratto et al. Advanced Science 2024, edited)

New Blood Test Device Modeled on Leeches to Help Diagnose Malaria

Many individuals have a fear of needles, making the experience of having blood drawn from their arm particularly distressing. An alternative method involves taking blood from the fingertip or earlobe,... Read more