We use cookies to understand how you use our site and to improve your experience. This includes personalizing content and advertising. To learn more, click here. By continuing to use our site, you accept our use of cookies. Cookie Policy.

LabMedica

Download Mobile App
Recent News Expo Clinical Chem. Molecular Diagnostics Hematology Immunology Microbiology Pathology Technology Industry Focus

New Method Tested for Early Diagnosis Pediatric Diabetic Nephropathy

By LabMedica International staff writers
Posted on 04 Aug 2016
Print article
Image: A histopathology of nodular glomerulosclerosis in the kidney of a patient with diabetic nephropathy (Photo courtesy of the CDC).
Image: A histopathology of nodular glomerulosclerosis in the kidney of a patient with diabetic nephropathy (Photo courtesy of the CDC).
In type 1 diabetic patients who have progressed to the final stages of nephropathy, kidney failure eventually develops in 50% of individuals within 10 years after the onset of overt nephropathy and in greater than 75% by the 20-year mark.

Nephropathy is diagnosed through the detection of increased urinary albumin excretion, but a growing body of evidence suggests that the risk for developing diabetic nephropathy starts when urinary albumin excretion levels are still within the normal range. If the onset of nephropathy could be detected before urinary albumin rises, patients could potentially be placed on treatment to prevent its development.

A team of scientists at the Aghia Sophia Children’s Hospital (Athens, Greece) has determined that two proteins, growth differentiation factor-15 (GDF-15) and chitinase-3-like protein 1 (YKL-40), could be used to detect diabetic nephropathy early. The team tested 56 type 1 diabetes patients mean age 13.1 ± 3.2 years and 49 healthy controls ages 12.8 ± 6.6 years, for GDF-15 and YKL-40 which were performed by means of immunoenzymatic and immunonephelometric techniques at time of enrollment in the study and after 12 to15 months. Also at these two time points, they evaluated subjects’ kidney function by measuring cystatin C to determine estimated glomerular filtration rate (eGFR) and measuring neutrophil gelatinase associated lipocalin (NGAL).

The teams found that after 12 to 15 months, GDF-15 levels in diabetes patients were significantly higher at 366.7 pg/mL than in healthy controls at 278.6 pg/mL. Initially, no significant difference in YKL-40 measurements was observed between diabetes patients and controls at time of enrollment, but over the course of the study, mean YKL-40 levels in diabetes patients proceeded to increase from 17.4 ng/mL to 20.5 ng/mL. GDF-15 levels also correlated negatively with eGFR values, while YKL-40 levels correlated positively with NGAL and GDF-15, indicating that rises in both proteins reflect a decline in kidney function.

Ioannis Papassotiriou, PhD, the team leader, said, “This is the first study to demonstrate a predictive role for serum GDF-15 and YKL-40 as early markers of diabetic nephropathy in children and adolescents with type 1 diabetes before severe overt nephropathy occurs. Defining new predictors as supplementary tests to urinary albumin excretion for the early diagnosis of diabetic nephropathy could accelerate effective management and treatment approaches needed to minimize the rates of severe renal morbidity and mortality in young patients with type 1 diabetes.”

Related Links:
Aghia Sophia Children’s Hospital

Platinum Member
COVID-19 Rapid Test
OSOM COVID-19 Antigen Rapid Test
Magnetic Bead Separation Modules
MAG and HEATMAG
Anti-Cyclic Citrullinated Peptide Test
GPP-100 Anti-CCP Kit
Gold Member
Fully Automated Cell Density/Viability Analyzer
BioProfile FAST CDV

Print article

Channels

Clinical Chemistry

view channel
Image: The 3D printed miniature ionizer is a key component of a mass spectrometer (Photo courtesy of MIT)

3D Printed Point-Of-Care Mass Spectrometer Outperforms State-Of-The-Art Models

Mass spectrometry is a precise technique for identifying the chemical components of a sample and has significant potential for monitoring chronic illness health states, such as measuring hormone levels... Read more

Molecular Diagnostics

view channel
Image: The fastGEN BCR::ABL1 Cancer kit offers a way to personalize treatment strategies for leukemia (Photo courtesy of BioVendor MDx)

First of Its Kind NGS Assay for Precise Detection of BCR::ABL1 Fusion Gene to Enable Personalized Leukemia Treatment

The BCR::ABL1 fusion gene plays a key role in the pathogenesis of several blood cancers, particularly chronic myeloid leukemia (CML). This gene results from a chromosomal translocation that causes constitutive... Read more

Hematology

view channel
Image: The CAPILLARYS 3 DBS devices have received U.S. FDA 510(k) clearance (Photo courtesy of Sebia)

Next Generation Instrument Screens for Hemoglobin Disorders in Newborns

Hemoglobinopathies, the most widespread inherited conditions globally, affect about 7% of the population as carriers, with 2.7% of newborns being born with these conditions. The spectrum of clinical manifestations... Read more

Immunology

view channel
Image: Exosomes can be a promising biomarker for cellular rejection after organ transplant (Photo courtesy of Nicolas Primola/Shutterstock)

Diagnostic Blood Test for Cellular Rejection after Organ Transplant Could Replace Surgical Biopsies

Transplanted organs constantly face the risk of being rejected by the recipient's immune system which differentiates self from non-self using T cells and B cells. T cells are commonly associated with acute... Read more

Microbiology

view channel
Image: The ePlex system has been rebranded as the cobas eplex system (Photo courtesy of Roche)

Enhanced Rapid Syndromic Molecular Diagnostic Solution Detects Broad Range of Infectious Diseases

GenMark Diagnostics (Carlsbad, CA, USA), a member of the Roche Group (Basel, Switzerland), has rebranded its ePlex® system as the cobas eplex system. This rebranding under the globally renowned cobas name... Read more

Pathology

view channel
Image: The new method is quick and easy, and can also be used by non-medical personnel. (Photo courtesy of Zoratto et al. Advanced Science 2024, edited)

New Blood Test Device Modeled on Leeches to Help Diagnose Malaria

Many individuals have a fear of needles, making the experience of having blood drawn from their arm particularly distressing. An alternative method involves taking blood from the fingertip or earlobe,... Read more