The blood test for glycosalated hemoglobin, Hb1Ac, has been recently recommended as the primary diagnostic test for diabetes.

The HbA1c blood test is the accepted standard for monitoring long-term glycemic control in patients with diabetes, however until recently, HbA1c was not recommended for diagnosing or screening for diabetes.

In a retrospective study carried out by DynaLIFEDx, Edmonton, AB, Canada) in conjunction with local medical practitioners, evaluated the positive predictive value (PPV) and negative predictive value (NPV) of HbA1c against the oral glucose tolerance test (OGTT) values using a 10% prevalence of diabetes in three locations. DynaLIFEDx is a major Canadian medical laboratory offering a complete range of diagnostic testing services. For a three-year period, 3,163 data pairs were collected including 1,537 males and 1,626 females with a mean age of 55.4 ± 14.7 years. The OGTT criteria for diabetes were found for 568 out of the 3,163 sets.

Blood glucose was measured on the ARCHITECT ci8200 (Abbott Laboratories; Mississauga, ON, Canada) using a hexokinase method and HbA1c was measured by high performance liquid chromatography (HPLC) on a VARIANT II analyzer (Bio-Rad laboratories, Montreal, QC, Canada). The recommended threshold HbA1c value of 6.5% did not give the optimal combination of NPV of 0.93 to 0.92 and PPV of 0.40 to 0.61 compared to a threshold HbA1c value of 7.0% that gave an NPV of 0.91 to 0.92, and PPV of 0.61 to 0.73.

The authors concluded that HbA1c is not satisfactory for use as a diagnostic test for diabetes using the threshold values recommended by the Consensus Committee and the International Expert panel due to low positive predictive values. About 12% of individuals with a normal OGTT test will be diagnosed with diabetes using a threshold HbA1c value of 7.0%. This would put considerable burden on health care resources. However, based on the high negative predictive value, HbA1c may be used as a test to rule-out diabetes. The study was published in the December 2011 issue of the journal Clinical Biochemistry.

Related Links:

DynaLIFEDx
Abbott Laboratories
Bio-Rad


Platinum Member
COVID-19 Rapid Test
OSOM COVID-19 Antigen Rapid Test
Magnetic Bead Separation Modules
MAG and HEATMAG
Complement 3 (C3) Test
GPP-100 C3 Kit
New
Gold Member
TORCH Panel Rapid Test
Rapid TORCH Panel Test

Print article

Channels

Hematology

view channel
Image: The CAPILLARYS 3 DBS devices have received U.S. FDA 510(k) clearance (Photo courtesy of Sebia)

Next Generation Instrument Screens for Hemoglobin Disorders in Newborns

Hemoglobinopathies, the most widespread inherited conditions globally, affect about 7% of the population as carriers, with 2.7% of newborns being born with these conditions. The spectrum of clinical manifestations... Read more

Immunology

view channel
Image: The AI predictive model identifies the most potent cancer killing immune cells for use in immunotherapies (Photo courtesy of Shutterstock)

AI Predicts Tumor-Killing Cells with High Accuracy

Cellular immunotherapy involves extracting immune cells from a patient's tumor, potentially enhancing their cancer-fighting capabilities through engineering, and then expanding and reintroducing them into the body.... Read more

Microbiology

view channel
Image: The T-SPOT.TB test is now paired with the Auto-Pure 2400 liquid handling platform for accurate TB testing (Photo courtesy of Shutterstock)

Integrated Solution Ushers New Era of Automated Tuberculosis Testing