LabMedica

Download Mobile App
Recent News Expo Clinical Chem. Molecular Diagnostics Hematology Immunology Microbiology Pathology Technology Industry Focus

Commercial Kits Evaluated for Mediterranean Visceral Leishmaniasis

By LabMedica International staff writers
Posted on 16 Apr 2020
Print article
Image: An enzyme-linked immunosorbent assay (ELISA) kit for the diagnosis of visceral leishmaniasis in humans (Photo courtesy of Bordier Affinity Products)
Image: An enzyme-linked immunosorbent assay (ELISA) kit for the diagnosis of visceral leishmaniasis in humans (Photo courtesy of Bordier Affinity Products)
Human visceral leishmaniasis (VL) is a neglected disease endemic in the Mediterranean region, caused by Leishmania infantum. Accurate VL diagnosis is critical for rapid and correct patient management. Dogs are the main reservoir of L. infantum parasites that are transmitted to humans by the bite of infected phlebotomine sand flies.

Parasite detection by microscopic examination of bone marrow aspirates is the gold standard method, but lacks sensitivity and requires invasive procedures. The culture of parasites isolated from patients might improve the diagnostic sensitivity. Various methods are used for VL serodiagnosis and molecular tests have been employed.

A team of scientists at the Université de Montpellier (Montpellier, France) and their international colleagues tested serum samples from 319 patients living in France, Tunisia or Morocco. The population of 181 with proven VL included 65 immunocompromised patients.

The serum samples were tested with two immunochromatographic tests (ICT): IT LEISH and TruQuick LEISH IgG/IgM (Meridianbioscience, Cincinnati, OH, USA) and four enzyme-linked immunosorbent assay (ELISA) reagents: NovaLisa Leishmania infantum IgG (NovaTec Immundiagnostica GmbH, Dietzenbach, Germany); Bordier Leishmania infantum (Bordier Affinity Products SA, Crissier, Switzerland); Ridascreen Leishmania IgG (R-Biopharm AG, Darmstadt, Germany); and Vircell Leishmania (Vircell, Granada, Spain).

The team reported that significantly higher percentages of false-negative results were obtained with all assays in immunocompromised patients, compared with the immunocompetent population. In the whole population, sensitivity and specificity ranged from 80.7% to 93.9% and from 95.7% to 100%, respectively. The maximum accuracy was observed with the Bordier and Vircell ELISA kits (96.2%), and the lowest accuracy with Ridascreen reagent (88.7%). New thresholds of positivity are proposed for the Bordier, Vircell and NovaLisa ELISA kits to achieve 95% sensitivity with the highest possible specificity. Western blot (WB), used as a confirmation method, showed 100% sensitivity and identified 10.1% of asymptomatic carriers among the control population from the South of France.

The authors concluded that the Vircell and Bordier ELISA kits displayed significantly higher accuracy rates in the whole population than the other tests. For field studies, the TruQuick ICT is the most suitable with satisfactory performances. In immunocompromised patients, the index values of all ELISA reagents were significantly lower than in the immunocompetent population and false-negative results were more frequent. The study was published on March 25, 2020 in the journal PLOS Neglected Tropical Diseases.


Gold Member
Antipsychotic TDM Assays
Saladax Antipsychotic Assays
Verification Panels for Assay Development & QC
Seroconversion Panels
New
Auto Clinical Chemistry Analyzer
cobas c 703
New
Respiratory QC Panel
Assayed Respiratory Control Panel

Print article

Channels

Molecular Diagnostics

view channel
Image: The study investigated D-dimer testing in patients who are at higher risk of pulmonary embolism (Photo courtesy of Adobe Stock)

D-Dimer Testing Can Identify Patients at Higher Risk of Pulmonary Embolism

Pulmonary embolism (PE) is a commonly suspected condition in emergency departments (EDs) and can be life-threatening if not diagnosed correctly. Achieving an accurate diagnosis is vital for providing effective... Read more

Microbiology

view channel
Image: Schematic representation illustrating the key findings of the study (Photo courtesy of UNIST)

Breakthrough Diagnostic Technology Identifies Bacterial Infections with Almost 100% Accuracy within Three Hours

Rapid and precise identification of pathogenic microbes in patient samples is essential for the effective treatment of acute infectious diseases, such as sepsis. The fluorescence in situ hybridization... Read more
Sekisui Diagnostics UK Ltd.