Analytical Performance Evaluated for Troponin T Gen 5 Assay

By LabMedica International staff writers
Posted on 05 Sep 2019
Image: The Elecsys Troponin T Gen 5 STAT assay (Photo courtesy of Roche Diagnostics).
Image: The Elecsys Troponin T Gen 5 STAT assay (Photo courtesy of Roche Diagnostics).
Increased blood concentrations of cardiac troponin (cTn) I and T are indicative of myocardial injury and are the preferred biomarkers for diagnosing acute myocardial infarction (AMI). The diagnosis of AMI requires a rise and/or fall in serial cTn measurements, in addition to other clinical features.

The introduction of high-sensitivity assays has enabled the rapid detection of subtle changes in cTn and facilitated earlier decision-making in the management of patients with suspected AMI, compared with less sensitive contemporary assays. These newer assays which can measure cTn concentrations 5 to 10 times lower than current assays and do so with improved analytical imprecision.

A team of Medical Scientists collaborating with the University of California San Diego Health (San Diego, CA, USA) analyzed the performance of the Elecsys Troponin T Gen 5 STAT assay. This assay is an electrochemiluminescence sandwich immunoassay, which uses two antibodies to form a sandwich complex with cTnT. A biotinylated monoclonal anti-cTnT-specific antibody and a monoclonal anti-cTnT-specific antibody labeled with ruthenium react to form a sandwich complex. Precision was evaluated per Clinical and Laboratory Standards Institute (CLSI) EP05-A2 using lithium-heparin plasma/quality control samples on Roche cobas e 411/cobas e 601 analyzers.

The scientists reported that the coefficients of variation (CV) for repeatability/intermediate precision were 0.7–5.6%/1.4–10.3% (cobas e 411; mean cardiac troponin T [cTnT]: 7.3–9,341 ng/L) and 0.7–3.0%/1.5–6.4% (cobas e 601; mean cTnT: 7.4–9,455 ng/L). There was no cross-reactivity with skeletal muscle troponin T (≤ 10,000 ng/L), skeletal muscle troponin I (≤ 100,000 ng/L), cardiac troponin I (≤ 10,000 ng/L), or human troponin C (≤ 80,000 ng/L). No interference was observed with biotin (≤ 20 ng/mL) or 34 drugs. The specified limit of blank and limit of detection were 3 ng/L and 5 ng/L, respectively, on the cobas e 411 analyzer, and 2.5 ng/L and 3 ng/L, respectively, on the cobas e 601 analyzer.

The authors concluded that the Elecsys TnT Gen 5 STAT assay demonstrated good analytical performance on cobas e 411 and cobas e 601 analyzers, with a CV of ≤ 10% at the 99th percentile URL. These findings support the routine use of the assay in clinical laboratories in the USA. The study was published in the August 2019 issue of the journal Clinica Chimica Acta.

Related Links:
University of California San Diego Health

Gold Member
Hybrid Pipette
SWITCH
POC Helicobacter Pylori Test Kit
Hepy Urease Test
Gel Cards
DG Gel Cards
Capillary Blood Collection Tube
IMPROMINI M3

Channels

Molecular Diagnostics

view channel
Image: The diagnostic device can tell how deadly brain tumors respond to treatment from a simple blood test (Photo courtesy of UQ)

Diagnostic Device Predicts Treatment Response for Brain Tumors Via Blood Test

Glioblastoma is one of the deadliest forms of brain cancer, largely because doctors have no reliable way to determine whether treatments are working in real time. Assessing therapeutic response currently... Read more

Immunology

view channel
Image: Circulating tumor cells isolated from blood samples could help guide immunotherapy decisions (Photo courtesy of Shutterstock)

Blood Test Identifies Lung Cancer Patients Who Can Benefit from Immunotherapy Drug

Small cell lung cancer (SCLC) is an aggressive disease with limited treatment options, and even newly approved immunotherapies do not benefit all patients. While immunotherapy can extend survival for some,... Read more

Microbiology

view channel
Image: New evidence suggests that imbalances in the gut microbiome may contribute to the onset and progression of MCI and Alzheimer’s disease (Photo courtesy of Adobe Stock)

Comprehensive Review Identifies Gut Microbiome Signatures Associated With Alzheimer’s Disease

Alzheimer’s disease affects approximately 6.7 million people in the United States and nearly 50 million worldwide, yet early cognitive decline remains difficult to characterize. Increasing evidence suggests... Read more

Technology

view channel
Image: Vitestro has shared a detailed visual explanation of its Autonomous Robotic Phlebotomy Device (photo courtesy of Vitestro)

Robotic Technology Unveiled for Automated Diagnostic Blood Draws

Routine diagnostic blood collection is a high‑volume task that can strain staffing and introduce human‑dependent variability, with downstream implications for sample quality and patient experience.... Read more

Industry

view channel
Image: Roche’s cobas® Mass Spec solution enables fully automated mass spectrometry in routine clinical laboratories (Photo courtesy of Roche)

New Collaboration Brings Automated Mass Spectrometry to Routine Laboratory Testing

Mass spectrometry is a powerful analytical technique that identifies and quantifies molecules based on their mass and electrical charge. Its high selectivity, sensitivity, and accuracy make it indispensable... Read more