Globotriaosylsphingosine Levels Measured in Fabry Disease Patients

By LabMedica International staff writers
Posted on 08 Sep 2021
Print article
Image: The AB SCIEX QTRAP 5500 System is a high sensitivity, bench top hybrid triple quadrupole-Linear Accelerator trap mass spectrometer designed for LC/MS/MS analyses (Photo courtesy of SCIEX)
Image: The AB SCIEX QTRAP 5500 System is a high sensitivity, bench top hybrid triple quadrupole-Linear Accelerator trap mass spectrometer designed for LC/MS/MS analyses (Photo courtesy of SCIEX)
Fabry disease (FD) is caused by an inborn error of glycosphingolipid metabolism, a genetic defect resulting in partial or complete deficiency of the lysosomal hydrolase alpha-galactosidase A (alpha-Gal A). This enzyme is responsible for breaking down glycolipids such as globotriaosylceramide and its deacylated derivative, globotriaosylsphingosine (LysoGb3).

In males, the classical Fabry phenotype generally arises in the pediatric age with acroparesthesia, hypo- or anhidrosis, angiokeratoma, corneal opacities (typically cornea verticillata) and microalbuminuria. Recently, LysoGb3 was found to be a useful biomarker in confirming FD diagnosis even in symptomatic females with normal or borderline leukocyte enzyme activity due to the effect of X-chromosome inactivation.

Clinical Scientists at the Meyer Children Hospital (Florence, Italy) and their colleagues carried out a prospective observational study enrolling 104 FD patients, 39 males and 65 females between the ages of 4 and 75 years from six clinical centers in Italy. Venous blood was collected. A portion was spotted onto filter paper (DBS) and another portion separated to obtain plasma.

The LysoGb3 concentrations in DBS and plasma were determined by highly sensitive electrospray ionization liquid chromatography tandem mass spectrometry. The data were obtained using an API 5500 QTRAP mass spectrometer (AB SCIEX, Concord, ON, Canada) equipped with Turbo Ion Spray source and operating in MRM positive ion mode. Chromatographic separation was achieved using an Agilent 1290 Infinity UHPLC capillary system (Agilent Technologies, Santa Clara, CA, USA).

The scientists reported that the method using DBS was validated by evaluating its precision, accuracy, matrix effect, recovery, and stability. Mean (±SEM) plasma and DBS levels of LysoGb3 in the 30 males with classical FD were 45.6 ± 9.2 and 40.6 ± 9.0 nmol/L, respectively, while in the nine males with late-onset FD, they were 9.2 ± 3.2 and 7.9 ± 2.4 nmol/L, respectively. Mean LysoGb3 levels in 54 females with a GLA variant associated with classical FD were 7.1 ± 0.6 (plasma) and 6.4 ± 0.5 nmol/L (DBS), while in the nine females with a GLA variant associated with late-onset FD LysoGb3 levels were 1.9 ± 0.7 (plasma) and 1.8 ± 0.5 nmol/L (DBS). There was a strong correlation between plasma and the corresponding DBS LysoGb3 concentrations, with few exceptions. Discrepancies were observed in anemic patients with typically low hematocrit levels compared to the normal range.

The authors concluded that the method proved to be efficient for the rapid analysis of LysoGb3. DBS provides a convenient, sensitive, and reproducible method for measuring LysoGb3 levels for diagnosis, initial phenotypic assignment, and therapeutic monitoring in patients with FD. The study was published on August 26, 2021 in the journal Clinical Chemistry and Laboratory Medicine.

Related Links:
Meyer Children Hospital
AB SCIEX
Agilent Technologies


Platinum Member
COVID-19 Rapid Test
OSOM COVID-19 Antigen Rapid Test
Magnetic Bead Separation Modules
MAG and HEATMAG
Anti-Cyclic Citrullinated Peptide Test
GPP-100 Anti-CCP Kit
New
Gold Member
Plasma Control
Plasma Control Level 1

Print article

Channels

Hematology

view channel
Image: The CAPILLARYS 3 DBS devices have received U.S. FDA 510(k) clearance (Photo courtesy of Sebia)

Next Generation Instrument Screens for Hemoglobin Disorders in Newborns

Hemoglobinopathies, the most widespread inherited conditions globally, affect about 7% of the population as carriers, with 2.7% of newborns being born with these conditions. The spectrum of clinical manifestations... Read more

Immunology

view channel
Image: Exosomes can be a promising biomarker for cellular rejection after organ transplant (Photo courtesy of Nicolas Primola/Shutterstock)

Diagnostic Blood Test for Cellular Rejection after Organ Transplant Could Replace Surgical Biopsies

Transplanted organs constantly face the risk of being rejected by the recipient's immune system which differentiates self from non-self using T cells and B cells. T cells are commonly associated with acute... Read more

Microbiology

view channel
Image: The ePlex system has been rebranded as the cobas eplex system (Photo courtesy of Roche)

Enhanced Rapid Syndromic Molecular Diagnostic Solution Detects Broad Range of Infectious Diseases

GenMark Diagnostics (Carlsbad, CA, USA), a member of the Roche Group (Basel, Switzerland), has rebranded its ePlex® system as the cobas eplex system. This rebranding under the globally renowned cobas name... Read more

Pathology

view channel
Image: The revolutionary autonomous blood draw technology is witnessing growing demands (Photo courtesy of Vitestro)

Robotic Blood Drawing Device to Revolutionize Sample Collection for Diagnostic Testing

Blood drawing is performed billions of times each year worldwide, playing a critical role in diagnostic procedures. Despite its importance, clinical laboratories are dealing with significant staff shortages,... Read more