Automated Hematologic Reference Intervals Defined for Newborns

By LabMedica International staff writers
Posted on 05 Jan 2021
Print article
Image: Hematologic Reference Intervals Defined for Newborns on the XN-1000 Automated Hematology Analyzer (Photo courtesy of Sysmex Corporation).
Image: Hematologic Reference Intervals Defined for Newborns on the XN-1000 Automated Hematology Analyzer (Photo courtesy of Sysmex Corporation).
Laboratory tests leverage 60% to 70% of medical decisions and one of the most often ordered and impactful tests is the complete blood count (CBC). These decisions require that clinicians have a standard for interpreting laboratory test results for their patients.

Ethical constraints exist for performing an unnecessary needle stick and collecting non-clinically indicated blood samples from this vulnerable newborn population. Many newborn CBC Reference Intervals (RI) publications have been retrospective and some authors cite this as one of their cardinal limitations.

A team of medical scientists associated with the Banner – University Medical Center Phoenix, (Phoenix, AZ, USA) conducted a prospective study at an academic tertiary care center, and hematology samples were collected from 120 participants deemed to be normal healthy term newborns. Study enrollment occurred between May 24, 2016, and November 1, 2017. A total of 170 blood specimens were sent to the laboratory.

The team used a single Sysmex XN-1000 Automated Hematology Analyzer (Sysmex America, Lincolnshire, IL, USA) to generate a CBC with white blood cell (WBC) differential for each newborn, including the advanced hematology parameters. Distributions were assessed for normality and tested for outliers. Reference intervals were values between the 2.5th percentile and 97.5th percentile.

The scientists reported that the novel reference intervals obtained for this study population are as follows: absolute immature granulocyte count, 80/μL to 1,700/μL; immature granulocyte percentage, 0.6% to 6.1%; reticulocyte hemoglobin equivalent, 31.7 to 38.4 pg; immature reticulocyte fraction, 35.9% to 52.8%; immature platelet count, 4.73 × 103/μL to 19.72 × 103/μL; and immature platelet fraction, 1.7% to 9.8%.

The authors concluded their prospective study has defined hematologic reference intervals for this newborn population, including new advanced clinical parameters from the Sysmex XN-1000 Automated Hematology Analyzer. These reference intervals are proposed as the new standard and can serve as a strong foundation for continued studies to further explore their value in diagnosing and managing morbidities such as sepsis, anemia, and thrombocytopenia. The study was published in the January, 2021 issue of the journal Archives of Pathology and Laboratory Medicine.

Related Links:
Banner – University Medical Center Phoenix
Sysmex America


Platinum Member
COVID-19 Rapid Test
OSOM COVID-19 Antigen Rapid Test
Magnetic Bead Separation Modules
MAG and HEATMAG
POCT Fluorescent Immunoassay Analyzer
FIA Go
New
Gold Member
Magnetic Bead Separation Modules
MAG and HEATMAG

Print article

Channels

Clinical Chemistry

view channel
Image: The 3D printed miniature ionizer is a key component of a mass spectrometer (Photo courtesy of MIT)

3D Printed Point-Of-Care Mass Spectrometer Outperforms State-Of-The-Art Models

Mass spectrometry is a precise technique for identifying the chemical components of a sample and has significant potential for monitoring chronic illness health states, such as measuring hormone levels... Read more

Immunology

view channel
Image: The AI predictive model identifies the most potent cancer killing immune cells for use in immunotherapies (Photo courtesy of Shutterstock)

AI Predicts Tumor-Killing Cells with High Accuracy

Cellular immunotherapy involves extracting immune cells from a patient's tumor, potentially enhancing their cancer-fighting capabilities through engineering, and then expanding and reintroducing them into the body.... Read more

Microbiology

view channel
Image: The T-SPOT.TB test is now paired with the Auto-Pure 2400 liquid handling platform for accurate TB testing (Photo courtesy of Shutterstock)

Integrated Solution Ushers New Era of Automated Tuberculosis Testing

Tuberculosis (TB) is responsible for 1.3 million deaths every year, positioning it as one of the top killers globally due to a single infectious agent. In 2022, around 10.6 million people were diagnosed... Read more