Anticoagulant Adjustment Evaluated Using Different Prothrombin Time Tests

By LabMedica International staff writers
Posted on 26 Nov 2020
Print article
Image: HemosIL RecombiPlasTin 2G assay: A high sensitivity thromboplastin reagent based on recombinant human tissue factor (RTF) for the quantitative determination in human citrated plasma of Prothrombin Time (Photo courtesy of Instrumentation Laboratories).
Image: HemosIL RecombiPlasTin 2G assay: A high sensitivity thromboplastin reagent based on recombinant human tissue factor (RTF) for the quantitative determination in human citrated plasma of Prothrombin Time (Photo courtesy of Instrumentation Laboratories).
Preanalytical variables may affect the results of routine coagulation assays. One important variable is hematocrit (Ht), which affects coagulation testing results. A sample with high Ht has lower plasma quantity, resulting in a dilution effect on the sample by an excess of the anticoagulant sodium citrate.

The prothrombin time/international normalized ratio (PT/INR) test is the assay used to monitor dose-adjustments of vitamin K antagonist (VKA) treatment. Thus, for patients on monitored oral anticoagulant therapy who present an elevated Ht, adjustment of sodium citrate volume is essential, otherwise, these patients would have an incorrect diagnosis or treatment.

Clinical Laboratory Scientists at the Universidade de Sao Paulo (Sao Paulo, Brazil) enrolled 181 patients from the pulmonary hypertension ambulatory group with elevated Ht (>55%) and on warfarin therapy. All patients were diagnosed with polycythemia due to pulmonary hypertension and received anticoagulation treatment at the anticoagulation ambulatory center.

Paired citrate-adjusted and unadjusted blood specimens were tested using the PT test using two different thromboplastin reagents that are routinely used in their laboratory: the first was the HemosIL RecombiPlasTin 2G, with a thromboplastin (International Sensitivity Index [ISI] 1.00) of lyophilized recombinant human tissue factor (RTF), and the second reagent was HemosIL PT-Fibrinogen HS Plus with a thromboplastin (ISI 1.24) lyophilized from rabbit brain extract (HS Plus). Both reagents were produced by Instrumentation Laboratories (Bedford, MA, USA). The results are expressed as the international normalized ratio (INR). The correlation and percent change (% change) between sample pairs were calculated.

The scientists reported that the INR-RTF results from adjusted and unadjusted citrate blood specimens showed a strong correlation. The INR median was 2.25 for citrate-adjusted samples and was 2.22 for citrate-unadjusted samples. For samples with Ht >62%, the % change between sample pairs was >10%. Results using HS Plus showed a moderate correlation between citrate-adjusted and unadjusted samples. The INR median was 2.51 for citrate-adjusted samples and 3.45 for citrate-unadjusted samples. For samples with Ht>55%, the % change between sample pairs was higher than 10%.

The authors concluded that the adjustment of citrate concentration in samples with markedly elevated hematocrit depends on the PT reagent used in the routine tests, and each laboratory must perform a validation assay. Their data suggest that with RecombiPlasTin 2G reagent, samples of patients with polycythemia on warfarin therapy with Ht up to 62% could be obtained in an unadjusted citrate concentration tube. Using this PT reagent, can reduce the number of collection tubes and length of patient stay and avoid recall of patients, meaning lower treatment costs and faster patient care. The study was published in the November. 2020 issue of the journal Practical Laboratory Medicine.

Related Links:
Universidade de Sao Paulo
Instrumentation Laboratories
Platinum Member
COVID-19 Rapid Test
OSOM COVID-19 Antigen Rapid Test
Magnetic Bead Separation Modules
MAG and HEATMAG
Complement 3 (C3) Test
GPP-100 C3 Kit
New
Gold Member
Liquid Ready-To-Use Lp(a) Reagent
Lipoprotein (a) Reagent

Print article

Channels

Clinical Chemistry

view channel
Image: The 3D printed miniature ionizer is a key component of a mass spectrometer (Photo courtesy of MIT)

3D Printed Point-Of-Care Mass Spectrometer Outperforms State-Of-The-Art Models

Mass spectrometry is a precise technique for identifying the chemical components of a sample and has significant potential for monitoring chronic illness health states, such as measuring hormone levels... Read more

Immunology

view channel
Image: The AI predictive model identifies the most potent cancer killing immune cells for use in immunotherapies (Photo courtesy of Shutterstock)

AI Predicts Tumor-Killing Cells with High Accuracy

Cellular immunotherapy involves extracting immune cells from a patient's tumor, potentially enhancing their cancer-fighting capabilities through engineering, and then expanding and reintroducing them into the body.... Read more

Microbiology

view channel
Image: The T-SPOT.TB test is now paired with the Auto-Pure 2400 liquid handling platform for accurate TB testing (Photo courtesy of Shutterstock)

Integrated Solution Ushers New Era of Automated Tuberculosis Testing

Tuberculosis (TB) is responsible for 1.3 million deaths every year, positioning it as one of the top killers globally due to a single infectious agent. In 2022, around 10.6 million people were diagnosed... Read more