We use cookies to understand how you use our site and to improve your experience. This includes personalizing content and advertising. To learn more, click here. By continuing to use our site, you accept our use of cookies. Cookie Policy.

LabMedica

Download Mobile App
Recent News Expo Clinical Chem. Molecular Diagnostics Hematology Immunology Microbiology Pathology Technology Industry Focus

Prognostic Values of Platelet Parameters in Gynecological Tumors Patients

By LabMedica International staff writers
Posted on 24 Mar 2020
Print article
Image: The XE-5000 Hematology Analyzer is a high volume analyzer that offers unique clinical parameters to aid in better patient care (Photo courtesy of Sysmex Corporation).
Image: The XE-5000 Hematology Analyzer is a high volume analyzer that offers unique clinical parameters to aid in better patient care (Photo courtesy of Sysmex Corporation).
Gynecologic cancers often involve the uterus, ovaries, cervix, vulva, vagina, fallopian tubes, or the peritoneum. The most common gynecologic cancer in the USA is endometrial cancer, followed by ovarian cancer. Many gynecologic cancers manifest as pelvic masses.

Platelets are small, hematopoietic, and anucleate cells released by bone marrow megakaryocytes in the bloodstream, and were described as the major effectors of several physiological and pathophysiological processes, such as hemostasis, thrombosis, immunological defense mechanisms, and the development of inflammation.

Medical Laboratory Scientists at the Wenzhou Medical University (Wenzhou, China) included in a study a total of 1,062 women who underwent gynecological tumor surgery for the first time between January 2014 and February 2016. Platelet parameters were recorded on the basis of the first complete blood count (CBC) within two weeks before surgery.

Differences of platelet parameters (platelet count [PLT], plateletcrit [PCT], mean platelet volume [MPV], platelet‐large cell rate [P‐LCR], and platelet distribution width [PDW]) between different categories were analyzed by nonparametric test. Venous blood was drawn from patients after admission which would transport to the laboratory within one hour and measured by Sysmex XE5000 hematology analyzer (Sysmex Corporation, Kobe, Japan). All microscopic slides and immunohistochemistry of tissue excised intraoperatively were reviewed by two pathologists. Computed tomography (CT) scan and lymph node metastasis sites were used to detect metastatic status.

The investigators reported that the platelet count and PCT were significantly increased, and MPV and P‐LCR were significantly reduced in malign and benign gynecological tumor groups compared with the controls; PDW had no significant differences. There were no significant differences in PLT, PCT, MPV, P‐LCR, and PDW between different tumor locations and pathologic types. The optimal cutoff values of PLT, PCT, MPV and P‐LCR were 274, 0.26, 10.08, and 24.8 (AUC: 0.661, 0.643, 0.593, 0.562), and PCT had preferable sensibility and specificity (50.8% and 70.4%) in predicting the presence of gynecological tumors. According to survival analysis, increased PLT (≥274 × 109/L) and PCT (≥0.26), and induced MPV (<10.08 fL) and P‐LCR (<24.8%) were associated with shorter overall survival.

The authors concluded that the increased PLT and the decreased platelet volume were not only common in gynecological cancer, but also usual in gynecological benign tumors. PLT, PCT, MPV, and P‐LCR were useful auxiliary parameters for predicting the presence of gynecological tumor. In addition, increased PLT and PCT, or decreased MPV and P‐LCR indicated a heavier tumor burden and shorter overall survival. The study was published on March 13, 2020 in the Journal of Clinical Laboratory Analysis.

Related Links:
Wenzhou Medical University
Sysmex Corporation


Platinum Member
COVID-19 Rapid Test
OSOM COVID-19 Antigen Rapid Test
Magnetic Bead Separation Modules
MAG and HEATMAG
Complement 3 (C3) Test
GPP-100 C3 Kit
New
Gold Member
Magnetic Bead Separation Modules
MAG and HEATMAG

Print article

Channels

Clinical Chemistry

view channel
Image: The 3D printed miniature ionizer is a key component of a mass spectrometer (Photo courtesy of MIT)

3D Printed Point-Of-Care Mass Spectrometer Outperforms State-Of-The-Art Models

Mass spectrometry is a precise technique for identifying the chemical components of a sample and has significant potential for monitoring chronic illness health states, such as measuring hormone levels... Read more

Immunology

view channel
Image: The AI predictive model identifies the most potent cancer killing immune cells for use in immunotherapies (Photo courtesy of Shutterstock)

AI Predicts Tumor-Killing Cells with High Accuracy

Cellular immunotherapy involves extracting immune cells from a patient's tumor, potentially enhancing their cancer-fighting capabilities through engineering, and then expanding and reintroducing them into the body.... Read more

Microbiology

view channel
Image: The T-SPOT.TB test is now paired with the Auto-Pure 2400 liquid handling platform for accurate TB testing (Photo courtesy of Shutterstock)

Integrated Solution Ushers New Era of Automated Tuberculosis Testing

Tuberculosis (TB) is responsible for 1.3 million deaths every year, positioning it as one of the top killers globally due to a single infectious agent. In 2022, around 10.6 million people were diagnosed... Read more