LabMedica

Download Mobile App
Recent News Expo Clinical Chem. Molecular Diagnostics Hematology Immunology Microbiology Pathology Technology Industry Focus

Hepatic Dysfunction and Coagulopathy Quantified in Fatal Dengue Fever

By LabMedica International staff writers
Posted on 24 Dec 2019
Print article
Image: The LH 750 hematology analyzer is equipped with advanced technologies with nucleated red blood cell (NRBC) enumeration and random access capabilities (Photo courtesy of Fameco Medical)
Image: The LH 750 hematology analyzer is equipped with advanced technologies with nucleated red blood cell (NRBC) enumeration and random access capabilities (Photo courtesy of Fameco Medical)
Dengue fever (DF) is currently one of the most severe public health problems. Each year, an estimated 390 million dengue infections occur around the world. Clinical presentations of dengue are diverse and non-specific, often with unpredictable clinical progression and outcome.

Severe dengue is a leading cause of serious illness and death among children and adults in some Asian and Latin American countries. It requires management by medical professionals in hospitals. Hepatic dysfunction and abnormal coagulation factors are common in acute dengue illness, reflected by abnormal alanine aminotransferase (AST), aspartate aminotransferase (ALT), activated partial thromboplastin time (aPTT), and platelet counts.

Medical scientists at the National Cheng Kung University (Tainan, Taiwan) performed a retrospective study using 20,213 laboratory test results from 4,069 patients who were diagnosed with DF at NCKUH, a major tertiary hospital in Tainan city, between January and December 2015. Only those dengue patients who had at least one of the laboratory diagnosis criteria were included.

Serum from patients with suspected dengue infection was determined using the one-step immunochromatographic Dengue Duo Dengue NS1 Ag + Ab Combo assay (SD BIOLINE, Yongin, Korea). Hepatic markers were determined using a biochemical assay analyzer (Cobas 8000 c 702 module; Roche Diagnostics GmbH, Mannheim, Germany). Coagulation markers were tested using a Coulter LH 750 Hematology Analyzer (Beckman Coulter, Inc., Brea, CA, USA).

The team reported that there were 4,069 dengue patients, of which 0.9% died in one week after illness onset. Both AST and ALT values of the fatal group were significantly higher than those of the survivor group from Day 3 (AST median, 624 U/L versus 60 U/L, ALT median, 116 U/L versus 29 U/L) of illness onset and peaked on Day 6 (AST median, 9,805 U/L versus 90 U/L; ALT median, 1,504 U/L versus 49 U/L). The platelet counts of the fatal group declined significantly than those of the survivor group since Day 3 of illness onset (median, 19 ×103/μL versus 91 ×103/μL), and activated partial thromboplastin time (aPTT) values of the fatal group significantly prolonged longer since Day 5 (median, 68.7 seconds versus 40.1 seconds).

The authors concluded that the AST, ALT, and platelet counts should be monitored closely from Day 0 to Day 3 of dengue infection, and aPTT be followed up on Day 5 of infection to identify the individuals at risk for early mortality. The study was published on December 5, 2019 in the journal PLOS Neglected Tropical Diseases.

Related Links:
National Cheng Kung University
SD BIOLINE
Roche Diagnostics
Beckman Coulter


Platinum Member
COVID-19 Rapid Test
OSOM COVID-19 Antigen Rapid Test
Magnetic Bead Separation Modules
MAG and HEATMAG
Complement 3 (C3) Test
GPP-100 C3 Kit
Gold Member
ADAMTS-13 Protease Activity Test
ATS-13 Activity Assay

Print article

Channels

Clinical Chemistry

view channel
Image: The 3D printed miniature ionizer is a key component of a mass spectrometer (Photo courtesy of MIT)

3D Printed Point-Of-Care Mass Spectrometer Outperforms State-Of-The-Art Models

Mass spectrometry is a precise technique for identifying the chemical components of a sample and has significant potential for monitoring chronic illness health states, such as measuring hormone levels... Read more

Immunology

view channel
Image: The AI predictive model identifies the most potent cancer killing immune cells for use in immunotherapies (Photo courtesy of Shutterstock)

AI Predicts Tumor-Killing Cells with High Accuracy

Cellular immunotherapy involves extracting immune cells from a patient's tumor, potentially enhancing their cancer-fighting capabilities through engineering, and then expanding and reintroducing them into the body.... Read more

Microbiology

view channel
Image: The T-SPOT.TB test is now paired with the Auto-Pure 2400 liquid handling platform for accurate TB testing (Photo courtesy of Shutterstock)

Integrated Solution Ushers New Era of Automated Tuberculosis Testing

Tuberculosis (TB) is responsible for 1.3 million deaths every year, positioning it as one of the top killers globally due to a single infectious agent. In 2022, around 10.6 million people were diagnosed... Read more