LabMedica

Download Mobile App
Recent News Expo Clinical Chem. Molecular Diagnostics Hematology Immunology Microbiology Pathology Technology Industry Focus

Urine Particle Analyzer Compared with Standard Methods

By LabMedica International staff writers
Posted on 20 Nov 2017
Print article
Image: The UF-1000i automated urine particle analyzer (Photo courtesy of Sysmex).
Image: The UF-1000i automated urine particle analyzer (Photo courtesy of Sysmex).
Urinary tract infections (UTIs) are characterized by the presence of microbial pathogens within the urinary tract, and they represent one of the most common infections identified in both hospitalized and clinic patients. Most UTIs are easily treated without difficulty.

In certain patient populations, such as children, pregnant women, and the elderly, significant complications may arise. The symptoms observed with UTIs are diverse and can range from mild irritation with voiding to bacteremia or even sepsis. When sepsis is present, it can lead to death if it is not diagnosed and treated early.

Medical scientists working at Prescient Medicine (Hummelstown, PA, USA) and their colleagues compared data from urine samples collected in sterile containers for bacterial culture and microscopic analysis during a 3-month period in a laboratory at a 572-bed, acute-care hospital. Upon receipt, one sample was used to inoculate a 5% sheep blood agar and a MacConkey agar plate with a 0.001-mL calibrated loop.

The second sample was analyzed for bacteria and leukocytes with the Sysmex UF-1000i urine analyzer (Sysmex Corporation, Kobe, Japan) which is a fully automated, fluorescent flow cytometer that categorizes red blood cells, white blood cells, epithelial cells, small round cells, sperm cells, crystals, and pathologic and hyaline casts, yeast, and bacteria. The second sample was also analyzed by urinalysis-associated microscopy for the presence of epithelial cells, leukocytes, yeast, and bacteria.

Urine cultures showed no growth in 2,034 samples (50%) and growth of less than 104 colony-forming units (CFUs)/mL in 1,812 samples (45%). Of the 4.033 results, 754 samples (19%) showed bacterial growth of 105 CFUs/mL or more, and 190 samples (5%) were considered contaminated specimens because they contained multiple species. However, if the growth of bacteria exceeded the definition of a negative result, they were considered to be positive, even though the likelihood of a UTI was low in those patients. Of the culture-positive samples, the most commonly identified microorganisms were Escherichia coli and Klebsiella spp, which is consistent with known epidemiologic data.

Of the 4,033 unique urine samples obtained from adult patients, 2,736 (67.8%) specimens had positive white blood cell counts and bacteria and 1,215 (30.1%) specimens had negative white blood cell counts and bacteria as reported by the UF-1000i. The negative predictive value for any positive culture in the adult population included in the study was 95.5%, and the negative predictive value for positive cultures containing growth of 100,000 or more CFUs was 99.3% using the Sysmex UF-1000i. There were 373 unique urine specimens collected in pediatric patients and using the UF-1000i method, 269 specimens (72%) had positive white blood cell counts and bacteria, and 104 (27.9%) tested negative for an elevation in white blood cell counts and bacteria.

The authors concluded that the Sysmex UF-1000i showed 98% sensitivity and 93.7% specificity with a 95.5% negative predictive value. Thus, a negative screen with the UF-1000i using defined thresholds for white blood cell counts and bacteria was likely to be a true negative, decreasing the need for presumptive antibiotics. The study was published in the November 2017 issue of the journal Archives of Pathology & Laboratory Medicine.

Platinum Member
COVID-19 Rapid Test
OSOM COVID-19 Antigen Rapid Test
Magnetic Bead Separation Modules
MAG and HEATMAG
Anti-Cyclic Citrullinated Peptide Test
GPP-100 Anti-CCP Kit
New
Gold Member
Liquid Ready-To-Use Lp(a) Reagent
Lipoprotein (a) Reagent

Print article

Channels

Clinical Chemistry

view channel
Image: The 3D printed miniature ionizer is a key component of a mass spectrometer (Photo courtesy of MIT)

3D Printed Point-Of-Care Mass Spectrometer Outperforms State-Of-The-Art Models

Mass spectrometry is a precise technique for identifying the chemical components of a sample and has significant potential for monitoring chronic illness health states, such as measuring hormone levels... Read more

Hematology

view channel
Image: The CAPILLARYS 3 DBS devices have received U.S. FDA 510(k) clearance (Photo courtesy of Sebia)

Next Generation Instrument Screens for Hemoglobin Disorders in Newborns

Hemoglobinopathies, the most widespread inherited conditions globally, affect about 7% of the population as carriers, with 2.7% of newborns being born with these conditions. The spectrum of clinical manifestations... Read more

Immunology

view channel
Image: The AI predictive model identifies the most potent cancer killing immune cells for use in immunotherapies (Photo courtesy of Shutterstock)

AI Predicts Tumor-Killing Cells with High Accuracy

Cellular immunotherapy involves extracting immune cells from a patient's tumor, potentially enhancing their cancer-fighting capabilities through engineering, and then expanding and reintroducing them into the body.... Read more