Breath Analysis Aims To Reduce Unnecessary Antibiotic Prescriptions
By LabMedica International staff writers Posted on 23 Jun 2016 |
Image: The QP2010 Plus gas chromatography-mass spectrometry analyzer (Photo courtesy of Shimadzu).
A number of multiresistant pathogens including Acinetobacter baumannii place a heavy burden on ventilator-associated pneumonia (VAP) patients in intensive care units (ICU), and it is critically important to differentiate between bacterial infection and colonization to avoid prescribing unnecessary antibiotics.
Quantitative culture of lower respiratory tract (LRT) specimens, however, requires invasive procedures, however nowadays, volatile organic compounds (VOCs) have been studied in vitro and in vivo to identify pathogen-derived biomarkers. An efficient, fast, accurate, painless and affordable test has been developed that will assist doctors in prescribing antibiotics only when the treatment is absolutely necessary.
Scientists at Zhejiang University (Hangzhou, China) enrolled 20 patients with A. baumannii VAP (infection group), 20 ventilated patients with LRT A. baumannii colonization (colonization group) and 20 ventilated patients with neurological disorders, but without pneumonia or A. baumannii colonization (control group). A clinical isolate of A. baumannii strains was used for the in vitro culture experiment.
For breath sample collection and gas chromatography-mass spectrometry (GC-MS) analysis the team used a GC-MS, the QP2010 Plus (Shimadzu, Kyoto, Japan). The detected compounds corresponding to the peaks were identified by spectra matching with the above software and Mass Spectral Library (NIST 05). The retention time and mass spectrum similarities were used to identify the compounds of interest.
Certain compounds, including siloxanes, phthalate and adipate plasticizers, e.g. bis(2-ethylhexyl) phthalate and its degradation product 2-ethylhexanol, were also excluded initially. After this step, the 349 VOCs detected primarily in the in vitro studies were reduced to 21 VOCs, and the 245 VOCs detected in the in vivo study reduced to 19 VOCs. Actually, the selected compounds were present at least 90% of all samples in at least one of the groups.
Breath profiles could be visually differentiated between A. baumannii cultivation in vitro and culture medium, and among in vivo groups. In the in vitro experiment, nine compounds of interest (2,5-dimethyl-pyrazine, 1-undecene, isopentyl 3-methylbutanoate, decanal, 1,3-naphthalenediol, longifolene, tetradecane, iminodibenzyl and 3-methyl-indene) in the headspace were found to be possible A. baumannii derivations. While there were eight target VOCs (1-undecene, nonanal, decanal, 2,6,10-trimethyl-dodecane, 5-methyl-5-propyl-nonane, longifolene, tetradecane and 2-butyl-1-octanol) exhibiting characteristics of A. baumannii VAP derivations.
The authors concluded that the study mainly provides a proof of concept that the direct detection of exhaled A. baumannii-derived VOCs might be adopted for an early alert of the LRT bacterial presence in ventilated ICU patients and even different parasitic states (i.e. infection and colonization) of A. baumannii. The study was published on June 7, 2016, in the Journal of Breath Research.
Related Links:
Zhejiang University
Shimadzu
Quantitative culture of lower respiratory tract (LRT) specimens, however, requires invasive procedures, however nowadays, volatile organic compounds (VOCs) have been studied in vitro and in vivo to identify pathogen-derived biomarkers. An efficient, fast, accurate, painless and affordable test has been developed that will assist doctors in prescribing antibiotics only when the treatment is absolutely necessary.
Scientists at Zhejiang University (Hangzhou, China) enrolled 20 patients with A. baumannii VAP (infection group), 20 ventilated patients with LRT A. baumannii colonization (colonization group) and 20 ventilated patients with neurological disorders, but without pneumonia or A. baumannii colonization (control group). A clinical isolate of A. baumannii strains was used for the in vitro culture experiment.
For breath sample collection and gas chromatography-mass spectrometry (GC-MS) analysis the team used a GC-MS, the QP2010 Plus (Shimadzu, Kyoto, Japan). The detected compounds corresponding to the peaks were identified by spectra matching with the above software and Mass Spectral Library (NIST 05). The retention time and mass spectrum similarities were used to identify the compounds of interest.
Certain compounds, including siloxanes, phthalate and adipate plasticizers, e.g. bis(2-ethylhexyl) phthalate and its degradation product 2-ethylhexanol, were also excluded initially. After this step, the 349 VOCs detected primarily in the in vitro studies were reduced to 21 VOCs, and the 245 VOCs detected in the in vivo study reduced to 19 VOCs. Actually, the selected compounds were present at least 90% of all samples in at least one of the groups.
Breath profiles could be visually differentiated between A. baumannii cultivation in vitro and culture medium, and among in vivo groups. In the in vitro experiment, nine compounds of interest (2,5-dimethyl-pyrazine, 1-undecene, isopentyl 3-methylbutanoate, decanal, 1,3-naphthalenediol, longifolene, tetradecane, iminodibenzyl and 3-methyl-indene) in the headspace were found to be possible A. baumannii derivations. While there were eight target VOCs (1-undecene, nonanal, decanal, 2,6,10-trimethyl-dodecane, 5-methyl-5-propyl-nonane, longifolene, tetradecane and 2-butyl-1-octanol) exhibiting characteristics of A. baumannii VAP derivations.
The authors concluded that the study mainly provides a proof of concept that the direct detection of exhaled A. baumannii-derived VOCs might be adopted for an early alert of the LRT bacterial presence in ventilated ICU patients and even different parasitic states (i.e. infection and colonization) of A. baumannii. The study was published on June 7, 2016, in the Journal of Breath Research.
Related Links:
Zhejiang University
Shimadzu
Latest Clinical Chem. News
- 3D Printed Point-Of-Care Mass Spectrometer Outperforms State-Of-The-Art Models
- POC Biomedical Test Spins Water Droplet Using Sound Waves for Cancer Detection
- Highly Reliable Cell-Based Assay Enables Accurate Diagnosis of Endocrine Diseases
- New Blood Testing Method Detects Potent Opioids in Under Three Minutes
- Wireless Hepatitis B Test Kit Completes Screening and Data Collection in One Step
- Pain-Free, Low-Cost, Sensitive, Radiation-Free Device Detects Breast Cancer in Urine
- Spit Test Detects Breast Cancer in Five Seconds
- Electrochemical Sensors with Next-Generation Coating Advances Precision Diagnostics at POC
- First-Of-Its-Kind Handheld Device Accurately Detects Fentanyl in Urine within Seconds
- New Fluorescent Sensor Array Lights up Alzheimer’s-Related Proteins for Earlier Detection
- Automated Mass Spectrometry-Based Clinical Analyzer Could Transform Lab Testing
- Highly Sensitive pH Sensor to Aid Detection of Cancers and Vector-Borne Viruses
- Non-Invasive Sensor Monitors Changes in Saliva Compositions to Rapidly Diagnose Diabetes
- Breakthrough Immunoassays to Aid in Risk Assessment of Preeclampsia
- Urine Test for Monitoring Changes in Kidney Health Markers Can Predict New-Onset Heart Failure
- AACC Releases Comprehensive Diabetes Testing Guidelines