LabMedica

Download Mobile App
Recent News Expo Clinical Chem. Molecular Diagnostics Hematology Immunology Microbiology Pathology Technology Industry Focus

Zika Virus IgM Antibody Found in West Nile Virus Patients

By LabMedica International staff writers
Posted on 05 Oct 2021
Print article
Image: The Zika IgM antibody-capture, enzyme-linked immunosorbent assay (Zika MAC-ELISA) for antibody testing (Photo courtesy of the Centers for Diseases Control and Prevention).
Image: The Zika IgM antibody-capture, enzyme-linked immunosorbent assay (Zika MAC-ELISA) for antibody testing (Photo courtesy of the Centers for Diseases Control and Prevention).
West Nile virus (WNV) and Zika virus (ZIKV) are mosquito-borne viruses in the family Flaviviridae. Residents in, and travelers to, areas where the viruses are circulating are at risk for infection, and both viruses can cause an acute febrile illness.

In the contiguous USA, WNV disease is the most commonly reported arboviral disease, with about 2,000 to 6,000 reported cases each year. WNV disease presentations range from mild febrile illness to severe neuroinvasive disease. Almost all ZIKV disease cases in the continental USA are travel associated.

Vector Borne Disease experts at the Centers for Diseases Control and Prevention (CDC, Fort Collins, CO, USA) included serum samples from 153 persons with confirmed recent WNV infection in their analysis. The median age of patients was 59 years (range 10–92 years) and 53 (35%) were female. Samples were collected at a median of seven days (range 0–40 days) after symptom onset. Serum samples were tested for the presence of ZIKV IgM antibody with CDC's envelope protein antigen-based ZIKV IgM antibody capture-ELISA (Zika MAC-ELISA). A P/N value <2.0 was interpreted as negative, a P/N from 2.0 to <3.0 was equivocal, and a P/N ≥ 3.0 was positive.

The scientists reported that among 153 sera from patients with acute WNV infection, the ZIKV IgM antibody result was positive in 56 (37%; 95% confidence interval [CI] 29–44%) and equivocal in 28 (18%; 95% CI 13–25%). With 55% of samples having cross-reactive antibodies, it is important for health care providers to request appropriate testing based on the most likely cause of a patient's possible arboviral infection considering their clinical symptoms and signs, travel history, and place of residence. Patients were significantly more likely to have a ZIKV IgM antibody-positive or equivocal result if their sample had both WNV and St. Louis encephalitis virus (SLEV)-neutralizing antibodies, compared with patients with samples with only WNV-neutralizing antibodies (relative risk = 2.1), and this association was not modified by nor required adjustment for sex.

The authors concluded that for cases where the epidemiology does not support the preliminary IgM findings, confirmatory neutralizing antibody testing should be performed. These measures will avoid an incorrect diagnosis of ZIKV infection, based on cross-reactive antibodies, in a person truly infected with WNV. The study was published on July 22, 2021 in the journal Vector-Borne and Zoonotic Diseases.

Related Links:
Centers for Diseases Control and Prevention

Gold Member
Serological Pipet Controller
PIPETBOY GENIUS
Verification Panels for Assay Development & QC
Seroconversion Panels
New
Vaginitis Test
Allplex Vaginitis Screening Assay
New
Fecal DNA Extraction Kit
QIAamp PowerFecal Pro DNA Kit

Print article

Channels

Clinical Chemistry

view channel
Image: The tiny clay-based materials can be customized for a range of medical applications (Photo courtesy of Angira Roy and Sam O’Keefe)

‘Brilliantly Luminous’ Nanoscale Chemical Tool to Improve Disease Detection

Thousands of commercially available glowing molecules known as fluorophores are commonly used in medical imaging, disease detection, biomarker tagging, and chemical analysis. They are also integral in... Read more

Microbiology

view channel
Image: The lab-in-tube assay could improve TB diagnoses in rural or resource-limited areas (Photo courtesy of Kenny Lass/Tulane University)

Handheld Device Delivers Low-Cost TB Results in Less Than One Hour

Tuberculosis (TB) remains the deadliest infectious disease globally, affecting an estimated 10 million people annually. In 2021, about 4.2 million TB cases went undiagnosed or unreported, mainly due to... Read more

Technology

view channel
Image: The HIV-1 self-testing chip will be capable of selectively detecting HIV in whole blood samples (Photo courtesy of Shutterstock)

Disposable Microchip Technology Could Selectively Detect HIV in Whole Blood Samples

As of the end of 2023, approximately 40 million people globally were living with HIV, and around 630,000 individuals died from AIDS-related illnesses that same year. Despite a substantial decline in deaths... Read more

Industry

view channel
Image: The collaboration aims to leverage Oxford Nanopore\'s sequencing platform and Cepheid\'s GeneXpert system to advance the field of sequencing for infectious diseases (Photo courtesy of Cepheid)

Cepheid and Oxford Nanopore Technologies Partner on Advancing Automated Sequencing-Based Solutions

Cepheid (Sunnyvale, CA, USA), a leading molecular diagnostics company, and Oxford Nanopore Technologies (Oxford, UK), the company behind a new generation of sequencing-based molecular analysis technologies,... Read more
Sekisui Diagnostics UK Ltd.