Predictors Evaluated for Microalbuminuria in Type 2 Diabetes

By LabMedica International staff writers
Posted on 12 Mar 2020
Image: The Gen‐S hematology analyzer provides a complete blood count, a five-part differential leukocyte count, and a reticulocyte count (Photo courtesy of InCav).
Image: The Gen‐S hematology analyzer provides a complete blood count, a five-part differential leukocyte count, and a reticulocyte count (Photo courtesy of InCav).
Chronic inflammation has an important role in the development and progression of type 2 diabetes through immunologic inflammatory mechanisms. The neutrophil‐to‐lymphocyte ratio (NLR) is a new, simple, and inexpensive marker of subclinical inflammation and has been used as a systemic inflammatory marker in chronic diseases.

A symptom of nephropathy is albuminuria usually initiating with microalbuminuria, which was found to be a marker of vascular endothelial damage. Albuminuria is a well‐known predictor of poor renal outcomes in patients with type 2 diabetes and in essential hypertension and as such, it is important to monitor and diagnose in order to treat early.

A team of medical scientists working with the Ziv Medical Center (Safed, Israel) included in their study the data from 168 patients with type 2 diabetes mellitus (DM), which included patients aged ≥40 years old who had type 2 DM for at least four years. Patients were classified into three groups according to glycated hemoglobin (HbA1c) and microalbuminuria: Group A were patients with controlled diabetes; Group B were patients with uncontrolled diabetes (both groups without microalbuminuria); and Group C, were patients with uncontrolled diabetes with microalbuminuria.

The team examined the patients records regarding plasma glucose, HbA1c, creatinine, albumin, total cholesterol, triglycerides (TG), high‐density lipoprotein (HDL), and low‐density lipoprotein (LDL) levels in the venous blood samples obtained in the morning after 8‐hours fasting. Complete blood counts were analyzed in the hematology unit with a Beckman‐Coulter Gen‐S hematology analyzer (Beckman Coulter Inc., Brea, CA, USA). Mean platelet volume (MPV) and red blood cell distribution width (RDW) levels were gathered from patients' complete blood count, and NLR was calculated as the ratio of absolute number of neutrophil and lymphocyte counts.

The scientists reported that a significant difference in NLR was found between Group C and groups A and B. A statistically significant difference in RDW was found between groups B and C. Receiver operating characteristic curve analysis of inflammatory markers and microalbuminuria prediction showed an area under curve (AUC) of 0.675 for NLR and 0.614 for RDW. NLR value of 2.54 has 39.7% sensitivity, 78.8% specificity, and 45% positive predictive value (PPV). RDW value of 14.44% has 37.9% sensitivity, 76% specificity, and 41.5% PPV. TG/HDL ratio was lower in patients with controlled diabetes (group A) compared to the other two groups. Serum creatinine was higher as was the ratio to microalbumin in group C compared to the other two study groups.

The authors concluded that high levels of NLR were found in diabetic patients with microalbuminuria compared to controlled and uncontrolled patients without microalbuminuria. At the same time, they found high RDW values in patients with diabetes with microalbuminuria compared to diabetic patients without microalbuminuria. The study was published on February 25, 2020 in the Journal of Clinical Laboratory Analysis.

Related Links:
Ziv Medical Center
Beckman Coulter Inc


Gold Member
Hybrid Pipette
SWITCH
POC Helicobacter Pylori Test Kit
Hepy Urease Test
New
Gold Member
Clinical Drug Testing Panel
DOA Urine MultiPlex
Automated Chemiluminescence Immunoassay Analyzer
MS-i3080

Channels

Molecular Diagnostics

view channel
Image: The diagnostic device can tell how deadly brain tumors respond to treatment from a simple blood test (Photo courtesy of UQ)

Diagnostic Device Predicts Treatment Response for Brain Tumors Via Blood Test

Glioblastoma is one of the deadliest forms of brain cancer, largely because doctors have no reliable way to determine whether treatments are working in real time. Assessing therapeutic response currently... Read more

Immunology

view channel
Image: Circulating tumor cells isolated from blood samples could help guide immunotherapy decisions (Photo courtesy of Shutterstock)

Blood Test Identifies Lung Cancer Patients Who Can Benefit from Immunotherapy Drug

Small cell lung cancer (SCLC) is an aggressive disease with limited treatment options, and even newly approved immunotherapies do not benefit all patients. While immunotherapy can extend survival for some,... Read more

Microbiology

view channel
Image: New evidence suggests that imbalances in the gut microbiome may contribute to the onset and progression of MCI and Alzheimer’s disease (Photo courtesy of Adobe Stock)

Comprehensive Review Identifies Gut Microbiome Signatures Associated With Alzheimer’s Disease

Alzheimer’s disease affects approximately 6.7 million people in the United States and nearly 50 million worldwide, yet early cognitive decline remains difficult to characterize. Increasing evidence suggests... Read more

Technology

view channel
Image: Vitestro has shared a detailed visual explanation of its Autonomous Robotic Phlebotomy Device (photo courtesy of Vitestro)

Robotic Technology Unveiled for Automated Diagnostic Blood Draws

Routine diagnostic blood collection is a high‑volume task that can strain staffing and introduce human‑dependent variability, with downstream implications for sample quality and patient experience.... Read more

Industry

view channel
Image: Roche’s cobas® Mass Spec solution enables fully automated mass spectrometry in routine clinical laboratories (Photo courtesy of Roche)

New Collaboration Brings Automated Mass Spectrometry to Routine Laboratory Testing

Mass spectrometry is a powerful analytical technique that identifies and quantifies molecules based on their mass and electrical charge. Its high selectivity, sensitivity, and accuracy make it indispensable... Read more