We use cookies to understand how you use our site and to improve your experience. This includes personalizing content and advertising. To learn more, click here. By continuing to use our site, you accept our use of cookies. Cookie Policy.

LabMedica

Download Mobile App
Recent News Expo Clinical Chem. Molecular Diagnostics Hematology Immunology Microbiology Pathology Technology Industry Focus

HbA1c Point-of-Care Test Reliably Diagnoses Diabetes

By LabMedica International staff writers
Posted on 11 Apr 2019
Print article
Image: The AfinionHbA1c assay cartridge is used to test for quantitative determination of glycated hemoglobin (HbA1c) in human whole blood, which is used to monitor metabolic control in patients with diabetes (Photo courtesy of Alere).
Image: The AfinionHbA1c assay cartridge is used to test for quantitative determination of glycated hemoglobin (HbA1c) in human whole blood, which is used to monitor metabolic control in patients with diabetes (Photo courtesy of Alere).
Glycated hemoglobin is a form of hemoglobin that is covalently bound to glucose. It is formed in a non-enzymatic glycation pathway by hemoglobin's exposure to plasma glucose.

By measuring glycated hemoglobin (HbA1c), clinicians are able to get an overall picture of what the average blood sugar levels have been over a period of weeks/months. Point-of-care (POC) hemoglobin A1c (HbA1c) testing has advantages over laboratory testing, but some questions have remained regarding the accuracy and precision of these methods.

Scientists collaborating with Abbott Rapid Diagnostics (San Diego, CA, USA) carried out a prospective and observational study using samples from 120 adults (mean age, 57 years; 56% women) across a range of HbA1c levels (4%-15%) that were taken by finger stick at three clinical sites in the USA. Four groups were formed based on HbA1c levels and categorized as low (4%-5.99%), threshold (6%-6.99%), medium (7%-9.99%) and high (more than 10%).

Venous blood samples were also taken from each participant, and three from each HbA1c group were analyzed using a POC test. The POC test assessed in the study was the Afinion HbA1c Dx test (Alere Technologies, Waltham, MA, USA). The precision of the POC test using venous blood was evaluated from samples run in four replicates on each of three test cartridge lots, twice per day for 10 consecutive days. The SD and CV by study site and overall were calculated.

The investigators found that using the point-of-care test with finger-stick and venous blood samples was “highly correlated” with the National Glycohemoglobin Standardization Program (NGSP) values. They also noted small bias results when comparing point-of-care testing by finger-stick testing (mean differential bias, –0.021%) and venous blood samples (mean differential bias, –0.005%). In addition, 97.5% of results from the finger-stick point-of-care tests and 97.1% of the venous blood point-of-care tests fell within 6% of the reference method from the Diabetes Control and Complications Trial. At least 92.5% of results are currently required to fall within this range by the NGSP, although the program will adjust the requirements to be 90% within 5% of the reference result this year. They noted that 95% of the finger-stick point-of-care test results and 93.3% of the venous blood POC test results fell within 5% of the reference in these new requirements.

The authors concluded that point-of-care HbA1c testing has the potential to expand patient access to diabetes diagnostic testing and expedite medical decisions and interventions aimed at the prevention of diabetes and its complications, particularly for those who face challenges in accessing traditional health care settings or attending multiple laboratory and physician follow-up appointments. The study was published on March 10, 2019, in the Journal of Diabetes Science and Technology.

Gold Member
Chagas Disease Test
CHAGAS Cassette
Verification Panels for Assay Development & QC
Seroconversion Panels
New
Silver Member
Verification Panels for Assay Development & QC
Seroconversion Panels
New
Piezoelectric Micropump
Disc Pump

Print article

Channels

Microbiology

view channel
Image: Schematic representation illustrating the key findings of the study (Photo courtesy of UNIST)

Breakthrough Diagnostic Technology Identifies Bacterial Infections with Almost 100% Accuracy within Three Hours

Rapid and precise identification of pathogenic microbes in patient samples is essential for the effective treatment of acute infectious diseases, such as sepsis. The fluorescence in situ hybridization... Read more

Industry

view channel
Image: BIOTIA-ID is an NGS platform that accurately and sensitively diagnoses infectious disease-causing pathogens (Photo courtesy of Adobe Stock)

New Collaboration to Advance Microbial Identification for Infectious Disease Diagnostics

With the rise of global pandemics, antimicrobial resistance, and emerging pathogens, healthcare systems worldwide are increasingly dependent on advanced diagnostic tools to guide clinical decisions.... Read more
Sekisui Diagnostics UK Ltd.