Immunochromatographic Test Rapidly Diagnoses Parasitic Infection

By LabMedica International staff writers
Posted on 15 Aug 2018
Print article
Image: Positive and negative results detected by the lateral flow immunochromatographic assay AcQuickDx test for Angiostrongylus cantonensis (Photo courtesy of Faculty of Medicine Siriraj Hospital).
Image: Positive and negative results detected by the lateral flow immunochromatographic assay AcQuickDx test for Angiostrongylus cantonensis (Photo courtesy of Faculty of Medicine Siriraj Hospital).
The rat lungworm Angiostrongylus cantonensis is a food-borne zoonotic parasite that causes eosinophilic meningitis in humans. Suspected cases of A. cantonensis infection can only be confirmed by finding the nematodes in cerebral spinal fluid (CSF) of the patients.

The serological diagnosis of human infection with Angiostrongylus cantonensis remains problematic because there are no commercially available validated tests. Most laboratories use domestically prepared tests such as the enzyme-linked immunosorbent assay (ELISA) or immunoblotting.

Scientists working with those at the Mahidol University (Bangkok, Thailand) assessed 97 serum samples: 19 samples from clinically diagnosed patients with detectable A. cantonensis-specific antibody in immunoblotting; 43 samples from patients with other parasitic diseases, such as gnathostomiasis, toxocariasis, trichinellosis, hookworm infection, filariasis, cysticercosis, paragonimiasis, opisthorchiasis, and malaria; and 35 samples from normal healthy subjects.

The test device was assembled with purified 31-kDa glycoprotein as diagnostic antigen and with gold-labeled anti-human immunoglobulin-G as the detector reagent. The team assessed the rapid lateral flow immunochromatographic assay designated AcQuickDx Test to detect anti-A. cantonensis antibodies in human sera. The appearance of a red band at the T line and a red band at the C line within 15 min indicates a positive reaction, whereas the absence of a red band at the T line and appearance of a red band at the C line indicates a negative reaction.

The team found that the sensitivity, specificity, positive predictive value and negative predictive value of AcQuickDx test to detect anti-A. cantonensis specific antibodies in serologically confirmed angiostrongyliasis cases were 100%, 98.72%, 95% and 100%, respectively. Positive AcQuickDx was observed in 1/4 cases with hookworm infections. No positive AcQuickDx was observed in cases with other parasitic diseases, and the individual healthy subjects.

The authors concluded that the AcQuickDx test is rapid, highly sensitive and specific, and easy to perform without additional equipment or ancillary supplies. It yields results that are interpreted visually, and possesses a long shelf life at room temperature. Thus, it can be applied as an additional test for clinical diagnostic support of angiostrongyliasis either in conventional laboratories or for remote areas where laboratory infrastructure is not available. The study was published in the August 2018 issue of the International Journal of Infectious Diseases.

Related Links:
Mahidol University

Gold Member
Rotavirus Test
Rotavirus Test - 30003 – 30073
Verification Panels for Assay Development & QC
Seroconversion Panels
New
Anti-HHV-6 IgM Assay
anti-HHV-6 IgM ELISA (semiquant.)
New
Toxoplasma Gondii Immunoassay
Toxo IgM AccuBind ELISA Kit

Print article

Channels

Clinical Chemistry

view channel
Image: The tiny clay-based materials can be customized for a range of medical applications (Photo courtesy of Angira Roy and Sam O’Keefe)

‘Brilliantly Luminous’ Nanoscale Chemical Tool to Improve Disease Detection

Thousands of commercially available glowing molecules known as fluorophores are commonly used in medical imaging, disease detection, biomarker tagging, and chemical analysis. They are also integral in... Read more

Microbiology

view channel
Image: The lab-in-tube assay could improve TB diagnoses in rural or resource-limited areas (Photo courtesy of Kenny Lass/Tulane University)

Handheld Device Delivers Low-Cost TB Results in Less Than One Hour

Tuberculosis (TB) remains the deadliest infectious disease globally, affecting an estimated 10 million people annually. In 2021, about 4.2 million TB cases went undiagnosed or unreported, mainly due to... Read more

Technology

view channel
Image: The HIV-1 self-testing chip will be capable of selectively detecting HIV in whole blood samples (Photo courtesy of Shutterstock)

Disposable Microchip Technology Could Selectively Detect HIV in Whole Blood Samples

As of the end of 2023, approximately 40 million people globally were living with HIV, and around 630,000 individuals died from AIDS-related illnesses that same year. Despite a substantial decline in deaths... Read more

Industry

view channel
Image: The collaboration aims to leverage Oxford Nanopore\'s sequencing platform and Cepheid\'s GeneXpert system to advance the field of sequencing for infectious diseases (Photo courtesy of Cepheid)

Cepheid and Oxford Nanopore Technologies Partner on Advancing Automated Sequencing-Based Solutions

Cepheid (Sunnyvale, CA, USA), a leading molecular diagnostics company, and Oxford Nanopore Technologies (Oxford, UK), the company behind a new generation of sequencing-based molecular analysis technologies,... Read more
Sekisui Diagnostics UK Ltd.