LabMedica

Download Mobile App
Recent News Expo Clinical Chem. Molecular Diagnostics Hematology Immunology Microbiology Pathology Technology Industry Focus

New Test Rapidly Diagnoses Preeclampsia

By LabMedica International staff writers
Posted on 09 Aug 2017
Print article
Image: A histopathology of a glomerulus from a patient with preeclampsia revealing a pronounced bubbly appearance in the consolidated areas, caused by swollen endothelial cells and podocytes (Photo courtesy of Dr. Vivette D’Agati, MD).
Image: A histopathology of a glomerulus from a patient with preeclampsia revealing a pronounced bubbly appearance in the consolidated areas, caused by swollen endothelial cells and podocytes (Photo courtesy of Dr. Vivette D’Agati, MD).
Preeclampsia can lead to kidney damage in many affected women and the only therapy currently available is delivery of the baby, but this often means that infants are born prematurely and may have medical problems related to their early delivery.

More effective treatment strategies will depend on methods that would diagnose women with preeclampsia in a timely manner and a better understanding of preeclampsia’s underlying mechanisms. Recent studies indicate that preeclampsia is linked with the abnormal presence in the urine of podocytes; however, available tests that can identify podocytes are expensive and time-consuming.

An international team of scientists collaborating with those at the Mayo Clinic, (Rochester, MN, USA) recruited at delivery a study population included 49 preeclamptic and 42 normotensive pregnant women. Plasma measurements included cell free fetal hemoglobin (HbF) concentrations and concentrations of the endogenous chelators haptoglobin, hemopexin, and α1- microglobulin. They assessed concentrations of urinary extracellular vesicles (EVs) containing immunologically detectable podocyte-specific proteins by digital flow cytometry and measured nephrinuria by an enzyme-linked immunosorbent assay (ELISA).

When the team compared the urine from women with normotensive pregnancies with urine from women with preeclamptic pregnancies, the latter contained a high ratio of podocin-positive to nephrin-positive urinary EVs (podocin+ EVs-to-nephrin+ EVs ratio) and increased nephrinuria, both of which correlated with proteinuria. Plasma levels of hemopexin, which were decreased in women with preeclampsia, negatively correlated with proteinuria, urinary podocin+ EVs-to-nephrin+ EVs ratio, and nephrinuria. They also found that fetal haemoglobin, which is normally present in pregnant women’s blood in small amounts, is present in higher amounts in pre-eclamptic women’s blood.

The authors concluded that their findings provide evidence that urinary EVs are reflective of preeclampsia-related altered podocyte protein expression. Furthermore, renal injury in preeclampsia associated with an elevated urinary podocin+ EVs-to-nephrin+ EVs ratio and may be mediated by prolonged exposure to cell free HbF.

Vesna D. Garovic, MD, a professor of Nephrology and Hypertension and the senior author of the study, said, “This increased amount of fetal haemoglobin in preeclampsia may be causing the release of podocyte fragments in the urine. We hope that this information will result in improved diagnostic procedures in women with pre-eclampsia; however, additional studies in larger numbers of patients and across different types of preeclampsia are needed.” The study was published on July 20, 2017, in the journal Clinical Journal of the American Society of Nephrology.

Related Links:
Mayo Clinic

Gold Member
Rotavirus Test
Rotavirus Test - 30003 – 30073
Verification Panels for Assay Development & QC
Seroconversion Panels
New
HIV-1 Test
HIV-1 Real Time RT-PCR Kit
New
Malaria Test
STANDARD Q Malaria P.f/Pan Ag

Print article

Channels

Clinical Chemistry

view channel
Image: The tiny clay-based materials can be customized for a range of medical applications (Photo courtesy of Angira Roy and Sam O’Keefe)

‘Brilliantly Luminous’ Nanoscale Chemical Tool to Improve Disease Detection

Thousands of commercially available glowing molecules known as fluorophores are commonly used in medical imaging, disease detection, biomarker tagging, and chemical analysis. They are also integral in... Read more

Microbiology

view channel
Image: The lab-in-tube assay could improve TB diagnoses in rural or resource-limited areas (Photo courtesy of Kenny Lass/Tulane University)

Handheld Device Delivers Low-Cost TB Results in Less Than One Hour

Tuberculosis (TB) remains the deadliest infectious disease globally, affecting an estimated 10 million people annually. In 2021, about 4.2 million TB cases went undiagnosed or unreported, mainly due to... Read more

Technology

view channel
Image: The HIV-1 self-testing chip will be capable of selectively detecting HIV in whole blood samples (Photo courtesy of Shutterstock)

Disposable Microchip Technology Could Selectively Detect HIV in Whole Blood Samples

As of the end of 2023, approximately 40 million people globally were living with HIV, and around 630,000 individuals died from AIDS-related illnesses that same year. Despite a substantial decline in deaths... Read more

Industry

view channel
Image: The collaboration aims to leverage Oxford Nanopore\'s sequencing platform and Cepheid\'s GeneXpert system to advance the field of sequencing for infectious diseases (Photo courtesy of Cepheid)

Cepheid and Oxford Nanopore Technologies Partner on Advancing Automated Sequencing-Based Solutions

Cepheid (Sunnyvale, CA, USA), a leading molecular diagnostics company, and Oxford Nanopore Technologies (Oxford, UK), the company behind a new generation of sequencing-based molecular analysis technologies,... Read more
Sekisui Diagnostics UK Ltd.