Study Shows Varied Results from Different Methods of Measuring Albumin

By LabMedica International staff writers
Posted on 21 Feb 2017
Print article
Image: A structural model of serum albumin (Photo courtesy of Wikimedia Commons).
Image: A structural model of serum albumin (Photo courtesy of Wikimedia Commons).
A recent paper compared the accuracy of several different methods for determining levels of serum or plasma albumin, measurements, which are used to evaluate the nutritional status, kidney function, and fluid balance of dialysis patients.

Investigators at the University of Virginia Health System and Virginia Commonwealth University used 24 testing methods offered by various companies to analyze pools that had been prepared from residual patient serum and heparin plasma from patients without renal disease, and serum from patients with kidney failure before hemodialysis. Albumin was measured in all samples and in ERM-DA470k/IFCC reference material (RM) by three immunochemical, nine bromcresol green (BCG), and 12 bromcresol purple (BCP) methods.

Results revealed that two of three immunochemical procedures, five of nine BCG, and 10 of 12 BCP methods recovered the RM value within its uncertainty. One immunochemical and three BCG methods were biased versus the RM value. Random error components were small for all measurement procedures. Biases for plasma samples were generally higher than for serum samples for all method types. For most measurement procedures, biases were lower for serum from patients on hemodialysis versus patients without kidney disease.

“Nephrologists follow albumin results closely because the results are going to tell them if they need to do anything extra for these patients,” said contributing author Dr. David Bruns, professor of pathology at the University of Virginia Health System. “We know for a fact that this [albumin levels] correlates with mortality. National guidelines define what an acceptable range is and what is not acceptable.”

The investigators concluded that significant differences among immunochemical, BCG, and BCP methods compromised the interpretation of serum albumin results. Therefore, guidelines and calculations for clinical management of kidney and other diseases must consider the method used for albumin measurement until harmonization can be achieved.

The study was published in the January 2017 issue of the journal Clinical Chemistry.

New
Gold Member
Rotavirus Test
Rotavirus Test - 30003 – 30073
Verification Panels for Assay Development & QC
Seroconversion Panels
New
Mycoplasma Pneumoniae Virus Test
Mycoplasma Pneumoniae Virus Detection Kit
New
Myeloperoxidase Assay
IDK MPO ELISA

Print article

Channels

Molecular Diagnostics

view channel
Image: The study investigated D-dimer testing in patients who are at higher risk of pulmonary embolism (Photo courtesy of Adobe Stock)

D-Dimer Testing Can Identify Patients at Higher Risk of Pulmonary Embolism

Pulmonary embolism (PE) is a commonly suspected condition in emergency departments (EDs) and can be life-threatening if not diagnosed correctly. Achieving an accurate diagnosis is vital for providing effective... Read more

Immunology

view channel
Image: The findings were based on patients from the ADAURA clinical trial of the targeted therapy osimertinib for patients with NSCLC with EGFR-activated mutations (Photo courtesy of YSM Multimedia Team)

Post-Treatment Blood Test Could Inform Future Cancer Therapy Decisions

In the ongoing advancement of personalized medicine, a new study has provided evidence supporting the use of a tool that detects cancer-derived molecules in the blood of lung cancer patients years after... Read more

Microbiology

view channel
Image: Schematic representation illustrating the key findings of the study (Photo courtesy of UNIST)

Breakthrough Diagnostic Technology Identifies Bacterial Infections with Almost 100% Accuracy within Three Hours

Rapid and precise identification of pathogenic microbes in patient samples is essential for the effective treatment of acute infectious diseases, such as sepsis. The fluorescence in situ hybridization... Read more
Sekisui Diagnostics UK Ltd.