LabMedica

Download Mobile App
Recent News Expo Clinical Chem. Molecular Diagnostics Hematology Immunology Microbiology Pathology Technology Industry Focus

Elevated Chitotriosidase Differentially Diagnoses Lysosomal Storage Disorders

By LabMedica International staff writers
Posted on 25 May 2016
Print article
Image: A bone marrow aspirate biopsy of a patient with Gaucher Disease; the cytoplasm has wrinkled tissue paper appearance (Photo courtesy of the American Society of Hematology).
Image: A bone marrow aspirate biopsy of a patient with Gaucher Disease; the cytoplasm has wrinkled tissue paper appearance (Photo courtesy of the American Society of Hematology).
Plasma chitotriosidase originates from activated macrophages and is reported to be elevated in many Lysosomal Storage Disorders. Measurement of this enzyme’s activity has been an available tool for monitoring therapy of Gaucher disease.

The degree of elevation of chitotriosidase is useful for differential diagnosis of Gaucher disease and Niemann Pick A/B. However the potential utility of this chitotriosidase assay depends on the frequency of deficient chitotriosidase activity in a particular population.

Scientists at Sandor Life Sciences (Hyderabad, India) studied the clinical utility of this assay for Gaucher and Niemann Pick A/B diseases in the backdrop of chitotriosidase deficiency in a local population. The study comprises 173 patients with clinical suspicion of 108 with Gaucher disease or 65 with Niemann Pick A/B and 92 healthy controls.

The scientists found that the plasma samples of controls, Gaucher disease, and Niemann Pick A/B showed chitotriosidase deficiency of 12%, 25% and 27% respectively. The degree of elevation of chitotriosidase in Gaucher disease was 40 to 326 fold (11,325.7 ± 6395.4 nmol/h/mL) and in Niemann Pick A/B patients it was seven to 22 fold (1192.5 ± 463.0 nmol/h/mL). Chitotriosidase deficiency is observed in 22% of the Indian population.

Serum chitotriosidase (CHIT) enzymatic activity is usually determined with the flurometric enzyme activity assay using artificial 4-methylumbelliferyl- substrate. Normal mean and standard deviation CHIT activity in elderly people has been reported as 270 ± 21 nmol/h/mL and in young people as 136 ± 17 nmol/h/mL, but in some individuals no enzyme activity has been observed.

The authors concluded that their findings of distinguishable fold elevation of chitotriosidase in Gaucher disease or Niemann Pick A/B can be a potential surrogate differential diagnostic marker for these groups of diseases, except in the patients in whom this enzyme is deficient. The study was published in the June 1, 2016, issue of the journal Clinica Chimica Acta.

Related Links:
Sandor Life Sciences

Gold Member
Antipsychotic TDM Assays
Saladax Antipsychotic Assays
Verification Panels for Assay Development & QC
Seroconversion Panels
New
Silver Member
ACTH Assay
ACTH ELISA
New
Community-Acquired Pneumonia Test
RIDA UNITY CAP Bac

Print article

Channels

Molecular Diagnostics

view channel
Image: The study investigated D-dimer testing in patients who are at higher risk of pulmonary embolism (Photo courtesy of Adobe Stock)

D-Dimer Testing Can Identify Patients at Higher Risk of Pulmonary Embolism

Pulmonary embolism (PE) is a commonly suspected condition in emergency departments (EDs) and can be life-threatening if not diagnosed correctly. Achieving an accurate diagnosis is vital for providing effective... Read more

Immunology

view channel
Image: The findings were based on patients from the ADAURA clinical trial of the targeted therapy osimertinib for patients with NSCLC with EGFR-activated mutations (Photo courtesy of YSM Multimedia Team)

Post-Treatment Blood Test Could Inform Future Cancer Therapy Decisions

In the ongoing advancement of personalized medicine, a new study has provided evidence supporting the use of a tool that detects cancer-derived molecules in the blood of lung cancer patients years after... Read more

Microbiology

view channel
Image: Schematic representation illustrating the key findings of the study (Photo courtesy of UNIST)

Breakthrough Diagnostic Technology Identifies Bacterial Infections with Almost 100% Accuracy within Three Hours

Rapid and precise identification of pathogenic microbes in patient samples is essential for the effective treatment of acute infectious diseases, such as sepsis. The fluorescence in situ hybridization... Read more
Sekisui Diagnostics UK Ltd.