Immunoassay for Human Cystic Echinococcosis Evaluated

By LabMedica International staff writers
Posted on 13 Apr 2016
Print article
Image: Photomicrograph of the ultrastructural morphology exhibited by an adult cestode, Echinococcus granulosus (Photo courtesy of Dr. Peter M. Schantz).
Image: Photomicrograph of the ultrastructural morphology exhibited by an adult cestode, Echinococcus granulosus (Photo courtesy of Dr. Peter M. Schantz).
Cystic echinococcosis (CE) is a neglected disease caused by the larval stage of the tapeworm Echinococcus granulosus complex affecting both humans and livestock. The disease is considered one of the world’s major zoonoses, and represents a public health problem.

The early phase of infection is generally asymptomatic. Small, well encapsulated, viable cysts or old cysts with pseudosolid content typically do not induce major pathology, and patients may remain asymptomatic for years or even permanently. At present, no marker of cyst viability and therapy efficacy exists, and serology may remain positive for years even after successful therapy. As a consequence, long-term follow-up with imaging is required for the clinical management of patients.

A team of scientists led by those at Porto Conte Ricerche (Tramariglio, Italy) examined a total of 327 sera from CE patients with heterogeneous conditions for cyst stage, cyst number, organ localization, drug therapy, and surgical intervention, together with 253 sera from healthy controls. The sera were first analyzed by an enzyme-linked immunosorbent assay (ELISA) based on the antigen 5 (Ag5) preparation in two different setups and, in parallel, by a commercial ELISA routinely used in clinical laboratories for CE serodiagnosis.

Sera were tested in duplicate in the parasitology diagnostic laboratory by laboratory personnel with long standing experience in diagnostic parasitology, using a commercial ELISA test (RIDASCREEN Echinococcus immunoglobulin G (IgG), (R-Biopharm, Darmstadt, Germany) for the detection of Echinococcus specific total IgG. Tests were read at 450 nm in a spectrophotometer, and a Sample Index (SI) was calculated and interpreted for each serum. ELISA was considered positive for SI greater than 1.1, negative for SI less than 0.9, and border line for 0.9 ≤SI ≤1.1. Sera were tested with the Ag5 ELISAs based on their Ag5 enriched preparation following two alternative setups. The absorbance was read at 620 nm after one-hour incubation using a Tecan Sunrise microplate reader (Tecan Group, Ltd.; Männedorf, Switzerland).

The Ag5 ELISAs revealed different sensitivity, 88.3% versus 95.3%, without significant differences in specificity, 94.1% versus 92.5%, for the two setups, respectively. Moreover, possible relationships between the Ag5 ELISA absorbance results and clinical variables were investigated. Chi squared test, bivariate logistic regression and multiple regression analyses highlighted differences in the serology reactivity according to pharmacological treatment, cyst activity, and cyst number.

The authors concluded that the good diagnostic sensitivity and the high reliability of the Ag5 preparation method make this antigen a promising candidate for the serodiagnosis of CE. Further studies will be needed to evaluate the ability of our test to provide useful information on specific CE clinical traits. The study was published on March, 29, 2016, in the journal Public Library of Science Neglected Tropical Diseases.

Related Links:

Porto Conte Ricerche
R-Biopharm 
Tecan Group, Ltd. 


New
Gold Member
Rotavirus Test
Rotavirus Test - 30003 – 30073
Verification Panels for Assay Development & QC
Seroconversion Panels
New
Malaria Test
STANDARD Q Malaria P.f/Pan Ag
New
Lyme Disease Test
Lyme IgG/IgM Rapid Test Cassette

Print article

Channels

Molecular Diagnostics

view channel
Image: The study investigated D-dimer testing in patients who are at higher risk of pulmonary embolism (Photo courtesy of Adobe Stock)

D-Dimer Testing Can Identify Patients at Higher Risk of Pulmonary Embolism

Pulmonary embolism (PE) is a commonly suspected condition in emergency departments (EDs) and can be life-threatening if not diagnosed correctly. Achieving an accurate diagnosis is vital for providing effective... Read more

Immunology

view channel
Image: The findings were based on patients from the ADAURA clinical trial of the targeted therapy osimertinib for patients with NSCLC with EGFR-activated mutations (Photo courtesy of YSM Multimedia Team)

Post-Treatment Blood Test Could Inform Future Cancer Therapy Decisions

In the ongoing advancement of personalized medicine, a new study has provided evidence supporting the use of a tool that detects cancer-derived molecules in the blood of lung cancer patients years after... Read more
Sekisui Diagnostics UK Ltd.