LabMedica

Download Mobile App
Recent News Expo Clinical Chem. Molecular Diagnostics Hematology Immunology Microbiology Pathology Technology Industry Focus

Saliva Collection Methods Evaluated for Proteome Analysis

By LabMedica International staff writers
Posted on 29 Apr 2013
Print article
The suitability of three different whole-saliva collection approaches for subsequent proteome analyses has been compared.

The saliva was obtained by passive drooling, cotton swabs and paraffin gums allowing similar coverage of the whole saliva proteome, but the specific proteins observed depended on the collection approach.

Scientists at the University Medicine Greifswald (Germany) collected saliva from nine healthy volunteers, four women and five men, whose mean age was 28 years. Subjects had to be free of fever, without a cold, and maintained good oral hygiene. Immediately, after saliva collection, a Proteinase Inhibitor Cocktail (Sigma Aldrich; St. Louis, MO, USA) was added and saliva collection by the three methods was performed on three consecutive days.

Stimulated Salivette Saliva was collected by Salivette with cotton swabs (Sarstedt; Nümbrecht, Germany). For the stimulated paraffin gum study, volunteers were asked to chew for one minute using commercially available paraffin gum (Ivoclar Vivadent; Schaan, Lichtenstein). Afterwards the fluid was collected in a 15 mL falcon tube. A 50 mL falcon tube was also used to collect for one minute the passive unstimulated drooled saliva from the volunteers. The protein lysates from the saliva samples were analyzed by shotgun liquid chromatography–mass spectrometry. The amount and concentration of the protein as well as protein profiling data of whole saliva were comparatively analyzed.

Samples collected using paraffin gum showed the highest saliva volume at 4.1 ± 1.5 mL, followed by Salivette collection at 1.8 ± 0.4 mL and drooling at 1.0 ± 0.4 mL. Saliva protein concentrations with a mean of 1,145 μg/mL showed no significant differences between the three sampling schemes. Each collection approach facilitated the identification of about 160 proteins with more than two distinct peptides per subject, but collection-method dependent variations in protein composition were observed.

The authors concluded that the three collection methods allows similar coverage of the whole saliva proteome, but the specific proteins observed depended on the collection approach. Therefore, only one type of collection device should be used for quantitative proteome analysis, especially when performing large-scale cross-sectional or multicentric studies. The study was published on April 18, 2013, in the journal Clinica Chimica Acta.

Related Links:

University Medicine Greifswald
Sigma Aldrich
Sarstedt


Gold Member
Serological Pipet Controller
PIPETBOY GENIUS
Verification Panels for Assay Development & QC
Seroconversion Panels
New
Anti-HHV-6 IgM Assay
anti-HHV-6 IgM ELISA (semiquant.)
New
Multi-Function Pipetting Platform
apricot PP5

Print article

Channels

Molecular Diagnostics

view channel
Image: The study investigated D-dimer testing in patients who are at higher risk of pulmonary embolism (Photo courtesy of Adobe Stock)

D-Dimer Testing Can Identify Patients at Higher Risk of Pulmonary Embolism

Pulmonary embolism (PE) is a commonly suspected condition in emergency departments (EDs) and can be life-threatening if not diagnosed correctly. Achieving an accurate diagnosis is vital for providing effective... Read more

Immunology

view channel
Image: The findings were based on patients from the ADAURA clinical trial of the targeted therapy osimertinib for patients with NSCLC with EGFR-activated mutations (Photo courtesy of YSM Multimedia Team)

Post-Treatment Blood Test Could Inform Future Cancer Therapy Decisions

In the ongoing advancement of personalized medicine, a new study has provided evidence supporting the use of a tool that detects cancer-derived molecules in the blood of lung cancer patients years after... Read more

Microbiology

view channel
Image: Schematic representation illustrating the key findings of the study (Photo courtesy of UNIST)

Breakthrough Diagnostic Technology Identifies Bacterial Infections with Almost 100% Accuracy within Three Hours

Rapid and precise identification of pathogenic microbes in patient samples is essential for the effective treatment of acute infectious diseases, such as sepsis. The fluorescence in situ hybridization... Read more
Sekisui Diagnostics UK Ltd.