We use cookies to understand how you use our site and to improve your experience. This includes personalizing content and advertising. To learn more, click here. By continuing to use our site, you accept our use of cookies. Cookie Policy.

LabMedica

Download Mobile App
Recent News Expo Clinical Chem. Molecular Diagnostics Hematology Immunology Microbiology Pathology Technology Industry Focus

Serum Extracellular Vesicle Arginase 1 Measured In T2DM

By LabMedica International staff writers
Posted on 18 Mar 2022
Print article
Image: The NanoSight NS300 utilizes the latest version of NanoSight’s particle characterization technology, Nanoparticle Tracking Analysis (NTA) (Photo courtesy of University of New South Wales)
Image: The NanoSight NS300 utilizes the latest version of NanoSight’s particle characterization technology, Nanoparticle Tracking Analysis (NTA) (Photo courtesy of University of New South Wales)

Type 2 diabetes mellitus (T2DM) has become one of the most pressing and prevalent epidemics in the last few decades and is associated with an increased risk of cardiovascular and cerebrovascular diseases with high mortality and disability.

Emerging evidence suggests that specific molecules derived from body fluids such as urine and blood are also closely associated with the presence of diabetes or diabetes-related diseases. As a new type of biomarker resource, extracellular vesicles (EVs) presented in accessible biofluids have garnered considerable attention due to their high stability in body fluids.

Medical Scientists at the Beijing Anzhen Hospital (Beijing, China) and their colleagues performed a cross-sectional study in 103 Chinese between the age of 32 and 89, including 73 T2DM patients and 30 non-T2DM. An overnight fasting blood sample was drawn from each participant into a serum collection tube. Serum triglycerides (TG), total cholesterol (TC), low-density lipoprotein cholesterol (LDL-C), high-density lipoprotein cholesterol (HDL-C) and other serum biochemical indexes were measured by biochemical analyzer (Hitachi 7600, Tokyo, Japan).

After centrifugation processing, the number and size of EVs was measured by Nanoparticle Tracking Analysis with a Nanosight NS300 instrument (Malvern, UK). Serum Extracellular Vesicle Arginase 1 (EV-derived ARG 1) concentration was measured using Human Arginase 1 Simplestep ELISA Kit (Abcam, Inc., Burlingame, CA, USA), a highly sensitive enzyme-linked immunosorbent assay kit. The OD value at 450 nm was recorded by an EnSpire microplate reader (Perkin Elmer Singapore Pte. Ltd., Singapore). Chemiluminescence signals from Western Blotting were visualized using supersensitive chemiluminescent substrates (Thermo Fisher Scientific, Waltham, MA, USA) and detected by an imaging system (Bio-Rad, Hercules, CA, USA).

The investigators reported that serum EV-derived ARG 1 levels were significantly higher in T2DM patients compared with non-T2DM patients. Correlation analysis revealed that serum EV-derived ARG 1 levels were positively associated with fasting plasma glucose (FPG) and glycated hemoglobin (HbA1c). Serum EV-derived ARG 1 levels were significantly associated with T2DM, especially in the subgroup of T2DM for more than 10 years (Odds Ratio (OR) = 1.651), after adjusting for confounding factors.

The authors concluded that their study there was a significant association between serum EV-derived ARG 1 levels and the presence and duration of T2DM. It would help explain in part that more vascular diseases occur in T2DM compared to non-T2DM. The study was published on March 11, 2022 in the journal BMC Endocrine Disorders.

Related Links:
Beijing Anzhen Hospital 
Hitachi 
Nanosight 
Abcam 
Perkin Elmer Singapore 
Thermo Fisher Scientific
Bio-Rad 

 

Platinum Member
COVID-19 Rapid Test
OSOM COVID-19 Antigen Rapid Test
Magnetic Bead Separation Modules
MAG and HEATMAG
Anti-Cyclic Citrullinated Peptide Test
GPP-100 Anti-CCP Kit
Gold Member
ADAMTS-13 Protease Activity Test
ATS-13 Activity Assay

Print article

Channels

Molecular Diagnostics

view channel
Image: A network of inflammatory molecules may act as biomarker for risk of future cerebrovascular disease (Photo courtesy of 123RF)

Simple Blood Test Could Enable First Quantitative Assessments for Future Cerebrovascular Disease

Cerebral small vessel disease is a common cause of stroke and cognitive decline, particularly in the elderly. Presently, assessing the risk for cerebral vascular diseases involves using a mix of diagnostic... Read more

Hematology

view channel
Image: The CAPILLARYS 3 DBS devices have received U.S. FDA 510(k) clearance (Photo courtesy of Sebia)

Next Generation Instrument Screens for Hemoglobin Disorders in Newborns

Hemoglobinopathies, the most widespread inherited conditions globally, affect about 7% of the population as carriers, with 2.7% of newborns being born with these conditions. The spectrum of clinical manifestations... Read more

Immunology

view channel
Image: Exosomes can be a promising biomarker for cellular rejection after organ transplant (Photo courtesy of Nicolas Primola/Shutterstock)

Diagnostic Blood Test for Cellular Rejection after Organ Transplant Could Replace Surgical Biopsies

Transplanted organs constantly face the risk of being rejected by the recipient's immune system which differentiates self from non-self using T cells and B cells. T cells are commonly associated with acute... Read more

Microbiology

view channel
Image: The ePlex system has been rebranded as the cobas eplex system (Photo courtesy of Roche)

Enhanced Rapid Syndromic Molecular Diagnostic Solution Detects Broad Range of Infectious Diseases

GenMark Diagnostics (Carlsbad, CA, USA), a member of the Roche Group (Basel, Switzerland), has rebranded its ePlex® system as the cobas eplex system. This rebranding under the globally renowned cobas name... Read more

Pathology

view channel
Image: The Aperio GT 450 DX has received US FDA 510(k) clearance (Photo courtesy of Leica Biosystems)

Use of DICOM Images for Pathology Diagnostics Marks Significant Step towards Standardization

Digital pathology is rapidly becoming a key aspect of modern healthcare, transforming the practice of pathology as laboratories worldwide adopt this advanced technology. Digital pathology systems allow... Read more