Essential Amino Acids Associated With Complications in Liver Transplant Recipients
By LabMedica International staff writers Posted on 02 Mar 2022 |
End stage liver disease is a major cause of morbidity and mortality worldwide and orthotopic liver transplantation (OLTx) is the only curative treatment. However, OLTx leads to its own risks and adverse sequelae.
The role of amino acids and their metabolism have recently gained more attention in this field of study. Specifically, branched-chain amino acids (BCAA) have repeatedly been associated with multiple cardiovascular and cardiometabolic morbidities that are observed in liver transplant recipients.
Hepatologists at the University Medical Center Groningen (Groningen, The Netherlands) and their colleagues performed a cross-sectional analysis of patients in a liver transplant subgroup and data from 336 participants were eligible for the study. The study group had a median age of 59 (IQR 46.0-67.0) years and was predominantly male (n=157; 57%). Data was collected between June 2015 and September 2019. During visits at the outpatient clinic, questionnaires, blood samples, 24-hour urine, feces, nails and hair were collected from all participants according to the TransplantLines protocol. Tissue samples and transplant biopsies were taken during transplant surgery.
Blood samples were drawn after an overnight fasting period of 8-12 hours and 24-hour urine specimens were collected at the same time. C-reactive protein (CRP), alanine aminotransferase (ALT), aspartate aminotransferase (AST), gamma-glutamyl transferase (GGT), alkaline phosphatase (ALP), albumin, HbA1c, fasting glucose, total cholesterol, high-density lipoprotein (HDL) cholesterol, low-density lipoprotein (LDL) cholesterol, triglycerides (TG), cytomegalovirus (CMV), Epstein Barr virus (EBV), eGFR, 24-hour urine protein and creatinine clearance were analyzed with standardized laboratory measurements.
Valine, leucine and isoleucine concentrations were measured in EDTA anti-coagulated plasma samples using a Vantera Clinical Analyzer (Labcorp, Morrisville, NC, USA), a fully automated, high-throughput, 400 MHz proton (1H) nuclear magnetic resonance (NMR) spectroscopy platform; in a standalone assay that has been optimized to quantify BCAA concentrations. BCAA quantified from the same samples using NMR and LC-MS/MS were highly correlated.
The investigators reported that the median of the total BCAA values was 358.5 (IQR 298.5-407.5) µmol/L in males and 300.0 (IQR 268.0-351.0) µmol/L in females. Patients in the highest tertile of BCAA values were more likely to have a higher BMI, higher systolic blood pressure, and higher prevalence of type 2 diabetes (T2D), high blood pressure and Metabolic Syndrome (MetS). Additionally, subjects with higher BCAA values had higher TG and lower HDL-cholesterol concentrations. Elevated HbA1c and fasting glucose values were also more frequently present in patients with higher BCAA values, while their eGFR was lower. In patients with viral liver disease a significant correlation with BCAA plasma levels could be observed in the total population, the group without metabolic syndrome and the T2D subgroup.
The authors concluded that elevated BCAA plasma levels are associated with T2D, MetS and the use of Sirolimus in stable OLTx recipients. BCAA plasma levels may be considered a biomarker that reflects an unfavorable metabolic status in liver transplant recipients. The study was published on February 7, 2022 in the journal Clinical Biochemistry.
Related Links:
University Medical Center Groningen
Labcorp
Latest Clinical Chem. News
- 3D Printed Point-Of-Care Mass Spectrometer Outperforms State-Of-The-Art Models
- POC Biomedical Test Spins Water Droplet Using Sound Waves for Cancer Detection
- Highly Reliable Cell-Based Assay Enables Accurate Diagnosis of Endocrine Diseases
- New Blood Testing Method Detects Potent Opioids in Under Three Minutes
- Wireless Hepatitis B Test Kit Completes Screening and Data Collection in One Step
- Pain-Free, Low-Cost, Sensitive, Radiation-Free Device Detects Breast Cancer in Urine
- Spit Test Detects Breast Cancer in Five Seconds
- Electrochemical Sensors with Next-Generation Coating Advances Precision Diagnostics at POC
- First-Of-Its-Kind Handheld Device Accurately Detects Fentanyl in Urine within Seconds
- New Fluorescent Sensor Array Lights up Alzheimer’s-Related Proteins for Earlier Detection
- Automated Mass Spectrometry-Based Clinical Analyzer Could Transform Lab Testing
- Highly Sensitive pH Sensor to Aid Detection of Cancers and Vector-Borne Viruses
- Non-Invasive Sensor Monitors Changes in Saliva Compositions to Rapidly Diagnose Diabetes
- Breakthrough Immunoassays to Aid in Risk Assessment of Preeclampsia
- Urine Test for Monitoring Changes in Kidney Health Markers Can Predict New-Onset Heart Failure
- AACC Releases Comprehensive Diabetes Testing Guidelines