Cord Blood and Filter Paper Screening Compared for Congenital Hypothyroidism
By LabMedica International staff writers Posted on 15 Dec 2021 |
Image: The Genetic Screen Processor (GSP) is a high throughput batch analyzer intended for quantitative or qualitative measurement of neonatal screening samples on 96-well microplates (Photo courtesy of PerkinElmer)
The most prevalent predisposing factor to intellectual disability is congenital hypothyroidism (CH), which is referred to the deficiency in thyroid hormone since birth. It could be either transient or persistent deficiency. Persistent deficiency of thyroid hormone requires life-long thyroid hormone replacement. This state is known as permanent congenital hypothyroidism.
Almost all infants with congenital hypothyroidism are asymptomatic at birth and show no signs, and consequently, the diagnosis is delayed due to a lack of clinical findings in most cases in the newborn period. Eventually, this will prompt the most serious result of congenital hypothyroidism, intellectual disability. Cord-blood and heel-prick thyroid-stimulating hormone (TSH) levels are essential in diagnosing and preventing the serious complications of congenital hypothyroidism.
Pediatricians at the King Abdulaziz Medical City (Jeddah, Saudi Arabia) and their colleagues conducted a comparative cross-sectional study that included 21,012 newborn screened babies for congenital hypothyroidism starting from September 2013 until March 2019. Both cord-blood and heel-prick TSH were collected from each newborn.
For cord blood, TSH was performed using i2000 Architect chemiluminescent immunoassay, (Abbott Diagnostics, Abbott Park, IL, USA). TSH measurement in heel-prick sample using dry blood spot filter paper was performed using a Genetic Screen Processor (PerkinElmer, Waltham, MA, USA). Heel prick and cord-blood TSH cutoff values of >21 μU/ml and >30 mIU/L respectively were considered positive.
The scientists reported that out of the total screened newborns, 12 were confirmed for having primary congenital hypothyroidism. Nine cases were positive for cord-blood TSH (Sensitivity 75%, specificity 99.9%, and a recall rate of 0.004%), while 139 cases were positive for heel-prick blood TSH (Sensitivity of 100%, specificity of 99.3%, and a recall rate of 0.60%). Male, full term babies with normal birth weight had higher TSH levels in both heel prick and cord blood in comparison with others. Cord-blood-positive CH cases were only term (100%) with normal birth weight (100%) and were predominantly females (70%).
The authors concluded that for the screening of CH, heel prick is considered a superior method, but cord blood remains a practical option due to its cost-effectiveness, immediate action, and lower recall rate. Therefore, whenever recall is difficult and/or early discharge is the practice, cord blood is an alternative method to heel prick, but not with cases of prematurity. The study was published on December 3, 3021 in the Journal of Clinical Laboratory Analysis.
Related Links:
King Abdulaziz Medical City
Abbott Diagnostics
PerkinElmer
Almost all infants with congenital hypothyroidism are asymptomatic at birth and show no signs, and consequently, the diagnosis is delayed due to a lack of clinical findings in most cases in the newborn period. Eventually, this will prompt the most serious result of congenital hypothyroidism, intellectual disability. Cord-blood and heel-prick thyroid-stimulating hormone (TSH) levels are essential in diagnosing and preventing the serious complications of congenital hypothyroidism.
Pediatricians at the King Abdulaziz Medical City (Jeddah, Saudi Arabia) and their colleagues conducted a comparative cross-sectional study that included 21,012 newborn screened babies for congenital hypothyroidism starting from September 2013 until March 2019. Both cord-blood and heel-prick TSH were collected from each newborn.
For cord blood, TSH was performed using i2000 Architect chemiluminescent immunoassay, (Abbott Diagnostics, Abbott Park, IL, USA). TSH measurement in heel-prick sample using dry blood spot filter paper was performed using a Genetic Screen Processor (PerkinElmer, Waltham, MA, USA). Heel prick and cord-blood TSH cutoff values of >21 μU/ml and >30 mIU/L respectively were considered positive.
The scientists reported that out of the total screened newborns, 12 were confirmed for having primary congenital hypothyroidism. Nine cases were positive for cord-blood TSH (Sensitivity 75%, specificity 99.9%, and a recall rate of 0.004%), while 139 cases were positive for heel-prick blood TSH (Sensitivity of 100%, specificity of 99.3%, and a recall rate of 0.60%). Male, full term babies with normal birth weight had higher TSH levels in both heel prick and cord blood in comparison with others. Cord-blood-positive CH cases were only term (100%) with normal birth weight (100%) and were predominantly females (70%).
The authors concluded that for the screening of CH, heel prick is considered a superior method, but cord blood remains a practical option due to its cost-effectiveness, immediate action, and lower recall rate. Therefore, whenever recall is difficult and/or early discharge is the practice, cord blood is an alternative method to heel prick, but not with cases of prematurity. The study was published on December 3, 3021 in the Journal of Clinical Laboratory Analysis.
Related Links:
King Abdulaziz Medical City
Abbott Diagnostics
PerkinElmer
Latest Clinical Chem. News
- 3D Printed Point-Of-Care Mass Spectrometer Outperforms State-Of-The-Art Models
- POC Biomedical Test Spins Water Droplet Using Sound Waves for Cancer Detection
- Highly Reliable Cell-Based Assay Enables Accurate Diagnosis of Endocrine Diseases
- New Blood Testing Method Detects Potent Opioids in Under Three Minutes
- Wireless Hepatitis B Test Kit Completes Screening and Data Collection in One Step
- Pain-Free, Low-Cost, Sensitive, Radiation-Free Device Detects Breast Cancer in Urine
- Spit Test Detects Breast Cancer in Five Seconds
- Electrochemical Sensors with Next-Generation Coating Advances Precision Diagnostics at POC
- First-Of-Its-Kind Handheld Device Accurately Detects Fentanyl in Urine within Seconds
- New Fluorescent Sensor Array Lights up Alzheimer’s-Related Proteins for Earlier Detection
- Automated Mass Spectrometry-Based Clinical Analyzer Could Transform Lab Testing
- Highly Sensitive pH Sensor to Aid Detection of Cancers and Vector-Borne Viruses
- Non-Invasive Sensor Monitors Changes in Saliva Compositions to Rapidly Diagnose Diabetes
- Breakthrough Immunoassays to Aid in Risk Assessment of Preeclampsia
- Urine Test for Monitoring Changes in Kidney Health Markers Can Predict New-Onset Heart Failure
- AACC Releases Comprehensive Diabetes Testing Guidelines