We use cookies to understand how you use our site and to improve your experience. This includes personalizing content and advertising. To learn more, click here. By continuing to use our site, you accept our use of cookies. Cookie Policy.

LabMedica

Download Mobile App
Recent News Expo Clinical Chem. Molecular Diagnostics Hematology Immunology Microbiology Pathology Technology Industry Focus

Platelet Indices Analyzed for Tuberculosis and Diabetes Mellitus Co-Morbidity

By LabMedica International staff writers
Posted on 03 Jun 2021
Print article
Image: The Mindray BC-6800 hematology analyzer (Photo courtesy of Shenzhen Mindray Bio-Medical Electronics)
Image: The Mindray BC-6800 hematology analyzer (Photo courtesy of Shenzhen Mindray Bio-Medical Electronics)
Studies have demonstrated that some diseases accelerate Tuberculosis (TB) occurrence and development. Type 2 diabetes mellitus (DM) has been verified as one of the threatening risk factors for TB, and patients have three times the risk of developing TB compared to non-diabetic patients due to pathogenic mechanisms and metabolic factors.

Platelets are enucleate cells and have critical roles in thrombosis, homeostasis and the inflammatory response. When the internal environment is changed, platelet morphology may be altered and play a role in certain platelet-associated parameters, mainly including platelet count (PC), plateletcrit (PCT), platelet distribution width (PDW) and mean platelet volume (MPV).

Clinical Laboratorians at Nantong University College of Medicine (Nantong, China) enrolled in a study 246 patients admitted to the hospital and were distributed into three groups (113 TB, 59 DM and 74 TB + DM). A total of 133 individuals were also recruited as healthy controls (HC). Platelet indices, namely, platelet count (PC), mean platelet volume (MPV), plateletcrit (PCT) and platelet distribution width (PDW), were compared among the four groups, and the relationship with inflammatory markers was explored by using statistical software.

TB diagnose was based on positive results of Xpert MTB/RIF (Cepheid Inc., Sunnyvale, CA, USA). The team used BACTEC MGIT 960 rapid liquid isolate culture (Becton Dickinson, Sparks, MD, USA), and the GenoType check system (Hain Lifescience, Nehren, Germany), and MTB smear confirmation by Ziehl-Neelsen acid-fast stain. Full blood counts were carried out using Mindray BC-6800 hematology analyzer (Shenzhen Mindray Bio-Medical Electronics Co. Ltd., Shenzhen, China). The Erythrocyte sedimentation rate (ESR) and C-reactive protein (CRP) were also measured.

The scientists reported that MPV and PCT were significantly downregulated in TB + DM patients (9.95 ± 1.25 fL, 0.20 ± 0.05%, separately) compared with DM individuals (10.92 ± 1.17 fL, 0.22 ± 0.04%). Moreover, the changes in MPV were significantly higher in TB + DM patients (9.95 ± 1.25 fL) than in TB patients (9.42 ± 1.01 fL). MPV improved the diagnosis sensitivity when it was combined with clinical parameters, such as fasting blood glucose in DM and Mycobacterium tuberculosis culture result in TB (76.3% versus 64.9%, 72.6% versus 60.8%), respectively. In addition, the sensitivity and specificity of PCT in the differential diagnosis of DM patients versus TB + DM patients were 69.5 and 59.4%, respectively. PCT improved the diagnosis sensitivity when combined with fasting blood glucose in DM (72.9% versus 64.9%). In addition, MPV was linked to CRP and ESR in the TB + DM patients.

The authors concluded that MPV is a valuable candidate marker to screen for TB-DM coinfection risk, as the occurrence of TB developing into TB-DM coinfection will increase MPV levels, and DM developing into a DM-TB coinfection will decrease MPV levels. MPV has significant specificity and sensitivity for predicting and diagnosing DM-TB coinfection. The study was published on May 20, 2021 in the journal BMC Infectious Diseases.

Related Links:
Nantong University College of Medicine
Cepheid Inc
Becton Dickinson
Hain Lifescience
Shenzhen Mindray


Platinum Member
COVID-19 Rapid Test
OSOM COVID-19 Antigen Rapid Test
Magnetic Bead Separation Modules
MAG and HEATMAG
Complement 3 (C3) Test
GPP-100 C3 Kit
Gold Member
Xylazine Immunoassay Test
Xylazine ELISA

Print article

Channels

Clinical Chemistry

view channel
Image: The 3D printed miniature ionizer is a key component of a mass spectrometer (Photo courtesy of MIT)

3D Printed Point-Of-Care Mass Spectrometer Outperforms State-Of-The-Art Models

Mass spectrometry is a precise technique for identifying the chemical components of a sample and has significant potential for monitoring chronic illness health states, such as measuring hormone levels... Read more

Molecular Diagnostics

view channel
Image: A network of inflammatory molecules may act as biomarker for risk of future cerebrovascular disease (Photo courtesy of 123RF)

Simple Blood Test Could Enable First Quantitative Assessments for Future Cerebrovascular Disease

Cerebral small vessel disease is a common cause of stroke and cognitive decline, particularly in the elderly. Presently, assessing the risk for cerebral vascular diseases involves using a mix of diagnostic... Read more

Immunology

view channel
Image: Exosomes can be a promising biomarker for cellular rejection after organ transplant (Photo courtesy of Nicolas Primola/Shutterstock)

Diagnostic Blood Test for Cellular Rejection after Organ Transplant Could Replace Surgical Biopsies

Transplanted organs constantly face the risk of being rejected by the recipient's immune system which differentiates self from non-self using T cells and B cells. T cells are commonly associated with acute... Read more

Microbiology

view channel
Image: The ePlex system has been rebranded as the cobas eplex system (Photo courtesy of Roche)

Enhanced Rapid Syndromic Molecular Diagnostic Solution Detects Broad Range of Infectious Diseases

GenMark Diagnostics (Carlsbad, CA, USA), a member of the Roche Group (Basel, Switzerland), has rebranded its ePlex® system as the cobas eplex system. This rebranding under the globally renowned cobas name... Read more

Pathology

view channel
Image: The Aperio GT 450 DX has received US FDA 510(k) clearance (Photo courtesy of Leica Biosystems)

Use of DICOM Images for Pathology Diagnostics Marks Significant Step towards Standardization

Digital pathology is rapidly becoming a key aspect of modern healthcare, transforming the practice of pathology as laboratories worldwide adopt this advanced technology. Digital pathology systems allow... Read more