Biomarker Evaluated for Early Detection of Congenital Heart Disease

By LabMedica International staff writers
Posted on 16 Dec 2020
Print article
Image: The GSP instrument is a high throughput batch analyzer intended for quantitative or qualitative measurement of neonatal screening samples on 96-well microplates (Photo courtesy of PerkinElmer).
Image: The GSP instrument is a high throughput batch analyzer intended for quantitative or qualitative measurement of neonatal screening samples on 96-well microplates (Photo courtesy of PerkinElmer).
Congenital heart disease (CHD) is the most common congenital malformation in humans worldwide. Circulating cardiovascular biomarkers could potentially improve the early detection of CHD, even in asymptomatic newborns.

The amino terminal fragment of the prohormone brain-type natriuretic peptide (NT-proBNP) test has been used in adults with cardiac failure. Evidence has found that the NT-proBNP test is useful in infants who require neonatal intensive care, children with pulmonary hypertension and cardiomyopathies, and children with various types of CHD.

Pediatricians at the University Teaching Hospital Ryhov (Jönköping, Sweden) and their colleagues prospectively enrolled healthy, term neonates born between July 1, 2018, and May 31, 2019 and compared them against retrospectively identified newborns with CHD born between September 1, 2003, and September 30, 2019. The CHD diagnosis was confirmed by echocardiography. Control newborns were followed-up for a minimum of one year using electronic patient records covering routine checkups and additional medical consultations.

The scientists developed a fully automated immunoassay for NT-proBNP measurement from dried blood spot (DBS) samples. Microtitration strips 96-well format were coated with anti-NT-proBNP mouse monoclonal IgG antibody (HyTest Ltd, Turku, Finland) and the monoclonal tracer antibody (HyTest Ltd) was labeled with europium chelate. The hematocrit in this mix was checked with a Coulter Ac · T diff Hematology Analyzer (Beckman Coulter, Brea, CA, USA). A high throughput batch analyzer (GSP Instrument; PerkinElmer, Waltham, MA, USA) was used for the plate assays.

Performed as early as two days after birth, a dried blood spot (DBS) test for NT-proBNP flagged 71% of the 34 tested babies with known CHD and 68% of the critical CHD cases. Combining the DBS test with pulse oximetry screening improved CHD detection to 82% and detection of critical CHD to 89%. Babies with CHD had a median NT-proBNP level of 17,240 ng/L based on the DBS test. Healthy controls had significantly lower NT-proBNP levels, with a median of 1,900 ng/L. A comparison of DBS and standard screening for NT-proBNP (laboratory analysis on 500 μL of blood in a collection tube containing EDTA as an anticoagulant) found the two tests to be highly correlated and in good agreement.

The authors concluded that the DBS NT-proBNP test discriminated well between healthy newborns and newborns with various types of CHD, including critical lesions. Additional reference values were established for days two to four of life, reflecting the timing of common newborn screening programs. The study was published on December 2, 2020 in the journal JAMA Network Open.

Related Links:
University Teaching Hospital Ryhov
HyTest Ltd
Beckman Coulter
PerkinElmer


Platinum Member
COVID-19 Rapid Test
OSOM COVID-19 Antigen Rapid Test
Magnetic Bead Separation Modules
MAG and HEATMAG
POCT Fluorescent Immunoassay Analyzer
FIA Go
Gold Member
Real-time PCR System
GentierX3 Series

Print article

Channels

Clinical Chemistry

view channel
Image: The 3D printed miniature ionizer is a key component of a mass spectrometer (Photo courtesy of MIT)

3D Printed Point-Of-Care Mass Spectrometer Outperforms State-Of-The-Art Models

Mass spectrometry is a precise technique for identifying the chemical components of a sample and has significant potential for monitoring chronic illness health states, such as measuring hormone levels... Read more

Hematology

view channel
Image: The CAPILLARYS 3 DBS devices have received U.S. FDA 510(k) clearance (Photo courtesy of Sebia)

Next Generation Instrument Screens for Hemoglobin Disorders in Newborns

Hemoglobinopathies, the most widespread inherited conditions globally, affect about 7% of the population as carriers, with 2.7% of newborns being born with these conditions. The spectrum of clinical manifestations... Read more

Microbiology

view channel
Image: The ePlex system has been rebranded as the cobas eplex system (Photo courtesy of Roche)

Enhanced Rapid Syndromic Molecular Diagnostic Solution Detects Broad Range of Infectious Diseases

GenMark Diagnostics (Carlsbad, CA, USA), a member of the Roche Group (Basel, Switzerland), has rebranded its ePlex® system as the cobas eplex system. This rebranding under the globally renowned cobas name... Read more

Pathology

view channel
Image: The revolutionary autonomous blood draw technology is witnessing growing demands (Photo courtesy of Vitestro)

Robotic Blood Drawing Device to Revolutionize Sample Collection for Diagnostic Testing

Blood drawing is performed billions of times each year worldwide, playing a critical role in diagnostic procedures. Despite its importance, clinical laboratories are dealing with significant staff shortages,... Read more