We use cookies to understand how you use our site and to improve your experience. This includes personalizing content and advertising. To learn more, click here. By continuing to use our site, you accept our use of cookies. Cookie Policy.

LabMedica

Download Mobile App
Recent News Expo Clinical Chem. Molecular Diagnostics Hematology Immunology Microbiology Pathology Technology Industry Focus

Pregnancy TSH Variations Prompt Erroneous Thyroid Disease Diagnosis

By LabMedica International staff writers
Posted on 22 Jun 2020
Print article
Image: Thyroid-stimulating hormone variations in pregnancy may prompt erroneous subclinical thyroid disease diagnosis (Photo courtesy of HealthEngine).
Image: Thyroid-stimulating hormone variations in pregnancy may prompt erroneous subclinical thyroid disease diagnosis (Photo courtesy of HealthEngine).
Thyroid-stimulating hormone is a pituitary hormone that stimulates the thyroid gland to produce thyroxine, and then triiodothyronine which stimulates the metabolism of almost every tissue in the body.

Physiologic variations in thyroid-stimulating hormone (TSH) concentrations may lead to a misclassification of subclinical thyroid disease for some healthy pregnant women, possibly subjecting women to unnecessary treatment.

Endocrinologists at the Medical University of Lodz (Rzgowska, Poland) and their colleagues assessed baseline concentrations of free T4, free T3, as well as TSH at 30 minute intervals (between 7.00 and 9.00 hours) in 110 healthy pregnant women, age 30.2 ± 6.0 years, 9.9 ± 2.4 weeks of gestation and in 19 female controls age 28.9 ± 10.7. The scientists analyzed data from the healthy pregnant women (mean age, 30 years; mean BMI, 24.9 kg/m²; mean gestational age, 9.9 weeks), hospitalized at Polish Mother’s Memorial Hospital Research Institute between 2017 and 2019, as well as the non-pregnant healthy women (mean age, 29 years; mean BMI, 28.3 kg/m²).

Based on data from 550 measurements, the team found that mean TSH concentrations were 1.62 mIU/L and 1.67 mIU/L among pregnant women and controls, respectively. Women who were Thyroid peroxidase (TPO) antibody-positive had a higher TSH concentration versus women who were TPO antibody-negative (mean TSH, 3.17 mIU/L versus 1.62 mIU/L). Taking into account the highest TSH out of five consecutive measurements, the scientists found that 20.9% of pregnant women had a TSH measurement greater than 2.5 mIU/L and 9.1% of pregnant women had a TSH measurement greater than 4 mIU/L.

When considering the lowest TSH value, the investigators observed TSH measurements greater than 2.5 mIU/L in 12.7% of pregnant women and TSH measurements greater than 4 mIU/L in 3.6% of pregnant women. The team found that the discrepancy was even greater for women who were TPO antibody-negative, varying between 21.2% versus 8.1% for a TSH greater than 2.5 mIU/L when considering the highest versus. the lowest TSH values, and varying between 6.06% versus 1.01% for a TSH greater than 4 mIU/L when considering the highest versus the lowest TSH values. They also found that TSH concentrations varied by 39.5% for pregnant women and by 42.47% among controls, with no between-group difference.

Andrzej Lewinski, MD, PhD, a Professor of Endocrinology and the senior author of the study, said, “Any decisions to instigate treatment, particularly during such a sensitive period like pregnancy, should be based on clear data that define what TSH and thyroid hormone concentrations are abnormal, as well as evidence of definite benefit of treatment. Furthermore, assessment of thyroid function should be performed during the first trimester of pregnancy, as fetal development is then almost entirely dependent on maternal thyroid hormone concentrations. In such circumstances, it is mandatory to ascertain that one is dealing with a genuine abnormality and not with physiological variations in hormone concentrations.” The study was published on May 19, 2020 in the journal Clinical Endocrinology.

Related Links:
Medical University of Lodz

Platinum Member
COVID-19 Rapid Test
OSOM COVID-19 Antigen Rapid Test
Magnetic Bead Separation Modules
MAG and HEATMAG
Anti-Cyclic Citrullinated Peptide Test
GPP-100 Anti-CCP Kit
New
Gold Member
Plasma Control
Plasma Control Level 1

Print article

Channels

Hematology

view channel
Image: The CAPILLARYS 3 DBS devices have received U.S. FDA 510(k) clearance (Photo courtesy of Sebia)

Next Generation Instrument Screens for Hemoglobin Disorders in Newborns

Hemoglobinopathies, the most widespread inherited conditions globally, affect about 7% of the population as carriers, with 2.7% of newborns being born with these conditions. The spectrum of clinical manifestations... Read more

Immunology

view channel
Image: Exosomes can be a promising biomarker for cellular rejection after organ transplant (Photo courtesy of Nicolas Primola/Shutterstock)

Diagnostic Blood Test for Cellular Rejection after Organ Transplant Could Replace Surgical Biopsies

Transplanted organs constantly face the risk of being rejected by the recipient's immune system which differentiates self from non-self using T cells and B cells. T cells are commonly associated with acute... Read more

Microbiology

view channel
Image: The ePlex system has been rebranded as the cobas eplex system (Photo courtesy of Roche)

Enhanced Rapid Syndromic Molecular Diagnostic Solution Detects Broad Range of Infectious Diseases

GenMark Diagnostics (Carlsbad, CA, USA), a member of the Roche Group (Basel, Switzerland), has rebranded its ePlex® system as the cobas eplex system. This rebranding under the globally renowned cobas name... Read more

Pathology

view channel
Image: The revolutionary autonomous blood draw technology is witnessing growing demands (Photo courtesy of Vitestro)

Robotic Blood Drawing Device to Revolutionize Sample Collection for Diagnostic Testing

Blood drawing is performed billions of times each year worldwide, playing a critical role in diagnostic procedures. Despite its importance, clinical laboratories are dealing with significant staff shortages,... Read more