LabMedica

Download Mobile App
Recent News Expo Clinical Chem. Molecular Diagnostics Hematology Immunology Microbiology Pathology Technology Industry Focus

Semi-Automatic Isoelectric Focusing Evaluated for Apolipoprotein E Phenotyping

By LabMedica International staff writers
Posted on 30 Jan 2020
Print article
Image: The Sebia Hydragel 18 Apo E Isofocusing showing different apoE isoforms from 16 patients tested. The “control serum” provided in the Sebia kit is included in each series, together with two already typed serum samples as internal controls (as an example, E3/E2 and E4/E4) (Photo courtesy of Sorbonne University).
Image: The Sebia Hydragel 18 Apo E Isofocusing showing different apoE isoforms from 16 patients tested. The “control serum” provided in the Sebia kit is included in each series, together with two already typed serum samples as internal controls (as an example, E3/E2 and E4/E4) (Photo courtesy of Sorbonne University).
Plasma apolipoprotein E (apoE) mainly arises from liver hepatocytes (75%), but the brain (astrocytes, oligodendrocytes, microglia, astrocytes) also synthesizes apoE found in the cerebrospinal fluid.

ApoE is a major component of lipoproteins which participates in the transport and clearance of lipids. ApoE4 status is a risk factor for Alzheimer’s and other neurodegenerative diseases, whereas apoE2 and also apoE4 increase the risk for cardiovascular disease.

A team of biochemists from the Sorbonne University (Paris, France) collected blood samples from 40 patients in the course of familial hypercholesterolemia screening or mixed dyslipidemia diagnosis. These patients had given their informed consent including genetic determination and APOE genotypes were already determined by Sanger sequencing of a polymerase chain reaction (PCR) fragment encompassing the two polymorphic sites (rs429358 and rs7412).

The scientists used the Hydragel 18 Apo E Isofocusing kit (Sebia, Lisses, France) which is a qualitative kit for detection and identification of the different apoE phenotypes. A ready-to-use agarose gel containing ampholytes (pH gradient: 5–8) is used to perform a semi-automatic electrophoresis on a Sebia Hydrasys 2 Scan, followed by a specific immunofixation with anti-apoE antiserum. The “apoE isofocusing visualization” kit included antiserum diluent, stock solutions of anti-apoE antiserum and peroxidase-labeled antibody, and reagent for revelation (TTF1 and TTF2 developing solutions).

The team reported that the sera from the genotyped patients included in the study allowed them to test the following isoforms: E3/E3 (18 sera), E3/E4 (16 sera), E2/E2 (four sera) and E4/E4 (two sera). All phenotypes tested were 100% concordant to the genetic isoforms, even if all the possible phenotypes are not found in their population. Precision of the technique was verified with the repeatability and the reproducibility tests for the different isoforms, since tests gave similar results. In addition, the reproducibility tests led them to perform three freezing-thawing cycles on serum samples and a 100% concordant interpretation with genotyping was maintained. There was no interference of hemolysis, glucose or hypertriglyceridemia at the respective concentrations of 45.3 μmol/L hemoglobin, 25.1 mmol/L glucose and 9.5 and 4.8 mmol/L triglycerides for the determination of the phenotype profile.

The authors concluded that this qualitative, semi-automatized method could yield a novel and simple tool to phenotype apoE isoforms. Validated on a cohort of patient samples with known genotype, it could be used either for screening and stratification of a patient cohort, or for clinical analysis when genetic material cannot be obtained. It could be a useful and supplementary tool helping the clinician in the diagnosis of dyslipidemic and neurodegenerative diseases. The study was published in the January 2020 issue of the journal Practical Laboratory Medicine.

Related Links:
Sorbonne University
Sebia


Platinum Member
COVID-19 Rapid Test
OSOM COVID-19 Antigen Rapid Test
Magnetic Bead Separation Modules
MAG and HEATMAG
POCT Fluorescent Immunoassay Analyzer
FIA Go
Gold Member
ADAMTS-13 Protease Activity Test
ATS-13 Activity Assay

Print article

Channels

Hematology

view channel
Image: The CAPILLARYS 3 DBS devices have received U.S. FDA 510(k) clearance (Photo courtesy of Sebia)

Next Generation Instrument Screens for Hemoglobin Disorders in Newborns

Hemoglobinopathies, the most widespread inherited conditions globally, affect about 7% of the population as carriers, with 2.7% of newborns being born with these conditions. The spectrum of clinical manifestations... Read more

Immunology

view channel
Image: The AI predictive model identifies the most potent cancer killing immune cells for use in immunotherapies (Photo courtesy of Shutterstock)

AI Predicts Tumor-Killing Cells with High Accuracy

Cellular immunotherapy involves extracting immune cells from a patient's tumor, potentially enhancing their cancer-fighting capabilities through engineering, and then expanding and reintroducing them into the body.... Read more

Microbiology

view channel
Image: The T-SPOT.TB test is now paired with the Auto-Pure 2400 liquid handling platform for accurate TB testing (Photo courtesy of Shutterstock)

Integrated Solution Ushers New Era of Automated Tuberculosis Testing

Tuberculosis (TB) is responsible for 1.3 million deaths every year, positioning it as one of the top killers globally due to a single infectious agent. In 2022, around 10.6 million people were diagnosed... Read more