High Performance of Rapid Influenza Diagnostic Test Validated
By LabMedica International staff writers Posted on 19 Dec 2019 |
Image: The Fuji dri-chem immuno AG cartridge FluAB kit (Photo courtesy of Fujifilm Corporation)
Influenza is a leading infectious cause of morbidity and mortality worldwide. Annually, about 5% to 10% of adults and 20% to 30% of children have symptoms of influenza-like illness (ILI), and approximately 650,000 deaths secondary to influenza occur each epidemic season.
Timely diagnosis and early antiviral therapy are crucial to counteract influenza spread. However, current diagnostic tools such as the real-time polymerase chain reaction (RT-PCR) are expensive and time-consuming. Some rapid influenza diagnostic tests (RIDTs) are also used to rapidly support treatment decision during influenza outbreaks. Nonetheless, RIDTs’ performance varies according to the prevalence of different influenza virus strains and the method used to determine their results.
A large group of scientists working with the National Institute of Respiratory Diseases (INER, Mexico City, Mexico) enrolled in their study 592 participants, 45.6% males and 54.3% females; their median age was 14 years. From these, 171 subjects (28.9%) received influenza vaccination for the evaluated season: 127 were immunized with the IIV3 and 44 received the IIV4. They enrolled the patients attending to the INER from October 2016 to March 2017.
The team used the Fuji dri-chem immuno AG cartridge FluAB kit (Fujifilm Corporation, Tokyo, Japan) for detection of influenza viruses in fresh respiratory specimens. This test utilizes the immunochromatographic principle of virus detection as other conventional rapid influenza diagnostic tests (RIDTs), adding the silver amplification principle of photographic development to improve its sensitivity. Detection of influenza viruses was assessed by RT-PCR and nucleic acid extraction from the clinical samples was performed with the PureLink Viral RNA/DNA mini kit (Thermo Fisher Scientific, Inc, Waltham MA, USA). The amplification was accomplished using the CFX96 Real Time System Bio-Rad Platform (Bio-Rad Laboratories Inc, Hercules, CA, USA).
The investigators reported that of the enrolled 592 patients. RT-PCR detected 93 cases of influenza A(H1N1)pdm09, 55 of AH3N2, 141 of B, and 13 A/B virus infections. RIDT showed 90.7% sensitivity and 95.7% specificity for influenza A virus detection, and 91.5% sensitivity and 95.3% specificity for influenza B virus detection. Overall vaccines’ effectiveness (VE) was 33.2% against any laboratory-confirmed influenza infection. VE estimates against influenza B were higher for the quadrivalent vaccine. Immunization and occupational exposure were protective factors against influenza.
The authors concluded that the RIDT was useful to detect influenza cases during an outbreak setting. Effectiveness of 2016/17 influenza vaccines administered in Mexico was low, but significant. The study was published in the December, 2019 issue of the International Journal of Infectious Diseases.
Related Links:
National Institute of Respiratory Diseases
Fujifilm Corporation
Thermo Fisher Scientific
Bio-Rad Laboratories
Timely diagnosis and early antiviral therapy are crucial to counteract influenza spread. However, current diagnostic tools such as the real-time polymerase chain reaction (RT-PCR) are expensive and time-consuming. Some rapid influenza diagnostic tests (RIDTs) are also used to rapidly support treatment decision during influenza outbreaks. Nonetheless, RIDTs’ performance varies according to the prevalence of different influenza virus strains and the method used to determine their results.
A large group of scientists working with the National Institute of Respiratory Diseases (INER, Mexico City, Mexico) enrolled in their study 592 participants, 45.6% males and 54.3% females; their median age was 14 years. From these, 171 subjects (28.9%) received influenza vaccination for the evaluated season: 127 were immunized with the IIV3 and 44 received the IIV4. They enrolled the patients attending to the INER from October 2016 to March 2017.
The team used the Fuji dri-chem immuno AG cartridge FluAB kit (Fujifilm Corporation, Tokyo, Japan) for detection of influenza viruses in fresh respiratory specimens. This test utilizes the immunochromatographic principle of virus detection as other conventional rapid influenza diagnostic tests (RIDTs), adding the silver amplification principle of photographic development to improve its sensitivity. Detection of influenza viruses was assessed by RT-PCR and nucleic acid extraction from the clinical samples was performed with the PureLink Viral RNA/DNA mini kit (Thermo Fisher Scientific, Inc, Waltham MA, USA). The amplification was accomplished using the CFX96 Real Time System Bio-Rad Platform (Bio-Rad Laboratories Inc, Hercules, CA, USA).
The investigators reported that of the enrolled 592 patients. RT-PCR detected 93 cases of influenza A(H1N1)pdm09, 55 of AH3N2, 141 of B, and 13 A/B virus infections. RIDT showed 90.7% sensitivity and 95.7% specificity for influenza A virus detection, and 91.5% sensitivity and 95.3% specificity for influenza B virus detection. Overall vaccines’ effectiveness (VE) was 33.2% against any laboratory-confirmed influenza infection. VE estimates against influenza B were higher for the quadrivalent vaccine. Immunization and occupational exposure were protective factors against influenza.
The authors concluded that the RIDT was useful to detect influenza cases during an outbreak setting. Effectiveness of 2016/17 influenza vaccines administered in Mexico was low, but significant. The study was published in the December, 2019 issue of the International Journal of Infectious Diseases.
Related Links:
National Institute of Respiratory Diseases
Fujifilm Corporation
Thermo Fisher Scientific
Bio-Rad Laboratories
Latest Technology News
- New Diagnostic System Achieves PCR Testing Accuracy
- DNA Biosensor Enables Early Diagnosis of Cervical Cancer
- Self-Heating Microfluidic Devices Can Detect Diseases in Tiny Blood or Fluid Samples
- Breakthrough in Diagnostic Technology Could Make On-The-Spot Testing Widely Accessible
- First of Its Kind Technology Detects Glucose in Human Saliva
- Electrochemical Device Identifies People at Higher Risk for Osteoporosis Using Single Blood Drop
- Novel Noninvasive Test Detects Malaria Infection without Blood Sample
- Portable Optofluidic Sensing Devices Could Simultaneously Perform Variety of Medical Tests
- Point-of-Care Software Solution Helps Manage Disparate POCT Scenarios across Patient Testing Locations
- Electronic Biosensor Detects Biomarkers in Whole Blood Samples without Addition of Reagents
- Breakthrough Test Detects Biological Markers Related to Wider Variety of Cancers
- Rapid POC Sensing Kit to Determine Gut Health from Blood Serum and Stool Samples
- Device Converts Smartphone into Fluorescence Microscope for Just USD 50
- Wi-Fi Enabled Handheld Tube Reader Designed for Easy Portability