Laser Incubator Developed for Rapid Blood Group Typing
By LabMedica International staff writers Posted on 01 Oct 2019 |
Image: The Eclipse Immunohematology Analyzer incorporates STARGEL10 AUTO Card Stacker technology enabling the loading of 32 STARGEL10 AUTO cards at once (Photo courtesy of Haemokinesis).
Blood transfusion is a critical treatment for a variety of hematological conditions, including cancer chemotherapy, sickle cell disease treatments, bleeding trauma, including childbirth, and major surgery.
Over 21 million blood components are transfused in the USA alone every year; each having the potential for fatal hemolytic transfusion reactions if recipient and donor are not accurately matched. Identification of antigens and antibodies often requires incubation at human body temperature of 37 °C. Depending on the method, this incubation step can take 5 to 30 minutes.
Chemical Engineers at Monash University (Clayton, Australia) and their colleagues at Haemokinesis (Hallam, Australia) developed rapid optical heating via laser, where targeted illumination of a blood-antibody sample in a diagnostic gel card is converted into heat, via photothermal absorption. The laser-incubator heats the 75 µL blood-antibody sample to 37 °C in less than 30 seconds.
Whole blood samples were stored by refrigeration at 4 °C with ethylenediaminetetraacetic acid (EDTA) as anticoagulant and were used within two weeks post-collection. Reagent red blood cell solutions (Haemokinesis: Stargel10 3 cell screen,) were used for all RBC-antibody incubation tests. Immunoglobulin-G (IgG) anti-D antibody was used for all antibody tests except for the sensitivity control test. The RBC-antibody mixtures were prepared directly in the gel card wells (Haemokinesis Stargel10 AHG System). The gel card heating block (Prototype #5, Haemokinesis) has a fixed temperature of 37 °C. Temperature was detected during incubation directly inside the sample volume in a gel card well using a thermocouple probe.
The team showed that red blood cells act as photothermal agents under near-infrared laser incubation, triggering rapid antigen-antibody binding. They detected no significant damage to the cells or antibodies for laser incubations of up to fifteen minutes. They demonstrate laser-incubated immunohaematological testing to be both faster and more sensitive than current best practice, with clearly positive results seen from laser incubations of just 40 seconds.
Clare A. Manderson, PhD, the first author of the study, said, “Giving blood transfusions to people isn't as simple as giving O-negative to anybody. The 'universal donor' of O-negative blood can seriously harm a lot of people, even kill them. The world of pre-transfusion of blood group typing is huge, and it's really important that it's done quickly and accurately to help save lives.” The study was originally published online on August 2, 2019, in the journal Scientific Reports.
Related Links:
Monash University
Haemokinesis
Over 21 million blood components are transfused in the USA alone every year; each having the potential for fatal hemolytic transfusion reactions if recipient and donor are not accurately matched. Identification of antigens and antibodies often requires incubation at human body temperature of 37 °C. Depending on the method, this incubation step can take 5 to 30 minutes.
Chemical Engineers at Monash University (Clayton, Australia) and their colleagues at Haemokinesis (Hallam, Australia) developed rapid optical heating via laser, where targeted illumination of a blood-antibody sample in a diagnostic gel card is converted into heat, via photothermal absorption. The laser-incubator heats the 75 µL blood-antibody sample to 37 °C in less than 30 seconds.
Whole blood samples were stored by refrigeration at 4 °C with ethylenediaminetetraacetic acid (EDTA) as anticoagulant and were used within two weeks post-collection. Reagent red blood cell solutions (Haemokinesis: Stargel10 3 cell screen,) were used for all RBC-antibody incubation tests. Immunoglobulin-G (IgG) anti-D antibody was used for all antibody tests except for the sensitivity control test. The RBC-antibody mixtures were prepared directly in the gel card wells (Haemokinesis Stargel10 AHG System). The gel card heating block (Prototype #5, Haemokinesis) has a fixed temperature of 37 °C. Temperature was detected during incubation directly inside the sample volume in a gel card well using a thermocouple probe.
The team showed that red blood cells act as photothermal agents under near-infrared laser incubation, triggering rapid antigen-antibody binding. They detected no significant damage to the cells or antibodies for laser incubations of up to fifteen minutes. They demonstrate laser-incubated immunohaematological testing to be both faster and more sensitive than current best practice, with clearly positive results seen from laser incubations of just 40 seconds.
Clare A. Manderson, PhD, the first author of the study, said, “Giving blood transfusions to people isn't as simple as giving O-negative to anybody. The 'universal donor' of O-negative blood can seriously harm a lot of people, even kill them. The world of pre-transfusion of blood group typing is huge, and it's really important that it's done quickly and accurately to help save lives.” The study was originally published online on August 2, 2019, in the journal Scientific Reports.
Related Links:
Monash University
Haemokinesis
Latest Hematology News
- Next Generation Instrument Screens for Hemoglobin Disorders in Newborns
- First 4-in-1 Nucleic Acid Test for Arbovirus Screening to Reduce Risk of Transfusion-Transmitted Infections
- POC Finger-Prick Blood Test Determines Risk of Neutropenic Sepsis in Patients Undergoing Chemotherapy
- First Affordable and Rapid Test for Beta Thalassemia Demonstrates 99% Diagnostic Accuracy
- Handheld White Blood Cell Tracker to Enable Rapid Testing For Infections
- Smart Palm-size Optofluidic Hematology Analyzer Enables POCT of Patients’ Blood Cells
- Automated Hematology Platform Offers High Throughput Analytical Performance
- New Tool Analyzes Blood Platelets Faster, Easily and Accurately
- First Rapid-Result Hematology Analyzer Reports Measures of Infection and Severity at POC
- Bleeding Risk Diagnostic Test to Reduce Preventable Complications in Hospitals
- True POC Hematology Analyzer with Direct Capillary Sampling Enhances Ease-of-Use and Testing Throughput
- Point of Care CBC Analyzer with Direct Capillary Sampling Enhances Ease-of-Use and Testing Throughput
- Blood Test Could Predict Outcomes in Emergency Department and Hospital Admissions
- Novel Technology Diagnoses Immunothrombosis Using Breath Gas Analysis
- Advanced Hematology System Allows Labs to Process Up To 119 Complete Blood Count Results per Hour
- Unique AI-Based Approach Automates Clinical Analysis of Blood Data