We use cookies to understand how you use our site and to improve your experience. This includes personalizing content and advertising. To learn more, click here. By continuing to use our site, you accept our use of cookies. Cookie Policy.

LabMedica

Download Mobile App
Recent News Expo Clinical Chem. Molecular Diagnostics Hematology Immunology Microbiology Pathology Technology Industry Focus

Urinary Hydration Markers Tested for Storage Condition Validity

By LabMedica International staff writers
Posted on 27 Aug 2019
Print article
Image: The 3320 osmometer used to assess urine osmolality, a measure of urine concentration and hydration (Photo courtesy of Advanced Instruments).
Image: The 3320 osmometer used to assess urine osmolality, a measure of urine concentration and hydration (Photo courtesy of Advanced Instruments).
Fluid balance is an aspect of the homeostasis of organisms in which the amount of water in the organism needs to be controlled, via osmoregulation and behavior, such that the concentrations of electrolytes in the various body fluids are kept within healthy ranges.

The human kidneys will normally adjust to varying levels of water intake. The kidneys will require time to adjust to the new water intake level. This can cause someone who drinks a lot of water to become dehydrated more easily than someone who routinely drinks less. Analysis of urine specimens is widely utilized to determine day-to-day hydration status in individuals as well as for other markers of health.

Scientists at the University of North Carolina at Greensboro (Greensboro, NC, USA) enrolled eight males and 13 females (mean ± SD; age, 24 ± 5 years; body mass, 68.9 ± 24.2 kg; height, 160.2 ± 32.1 cm) without a history of renal disease or currently taking any medications or supplements known to affect the accuracy of urinary hydration markers. Participants provided a 24 hour urine sample in a clean container with each urine sample being separate into four separate containers, two in each of the following temperatures: 7 °C and 22 °C. One specimen container at each temperature was either sealed using the manufacturers cap (single sealed, SS) or the manufacturers cap plus laboratory wrapping film (double sealed, DS).

Each sample was analyzed after 1, 2, 3, 7 and 10 days. Urine samples were assessed for urine osmolality (UOSMO), urine specific gravity (USG), and urine color (UCOL). UOSMO was stable at 7 °C for two days and three days for single sealed and double sealed containers, respectively. UOSMO was determined via freezing point depression with a 3320 osmometer. USG was measured using an optical refractometer that was accurate to ±0.001 AU and had a resolution of 0.0001. UCOL was measured by comparing each urine sample to an 8-point urine color chart where the sample was held against a white background in a well-lit room.

The team reported that USG measures were stable for singled sealed and double sealed for up to ten days when stored at 22 °C. UCOL measures were maintained for up to three days in all storage methods. For refrigerated samples, UOSMO measures for samples stored in SS containers became significantly elevated three days following baseline measures, whereas UOSMO measures for samples stored in DS containers became significantly elevated seven days following baseline measures. Conversely to UOSMO, USG measures were significantly elevated in SS and DS samples stored at 7 °C beginning one day following baseline measures, compared to SS and DS samples stored at 20 °C.

The authors concluded that to achieve optimal results, it is recommended that 24-hour urine samples are assessed immediately for the respective hydration markers being analyzed. If immediate analysis is unavailable, such as in the case of field based or longitudinal research, it is recommended that 24-hour urine samples are stored in a refrigerated environment and hydration markers (UOSMO and UCOL) be assessed within 48 hours. The study was published on August 5, 2019, in the journal PLOS ONE.

Related Links:
University of North Carolina at Greensboro

Platinum Member
COVID-19 Rapid Test
OSOM COVID-19 Antigen Rapid Test
Magnetic Bead Separation Modules
MAG and HEATMAG
POCT Fluorescent Immunoassay Analyzer
FIA Go
New
Gold Member
Magnetic Bead Separation Modules
MAG and HEATMAG

Print article

Channels

Hematology

view channel
Image: The CAPILLARYS 3 DBS devices have received U.S. FDA 510(k) clearance (Photo courtesy of Sebia)

Next Generation Instrument Screens for Hemoglobin Disorders in Newborns

Hemoglobinopathies, the most widespread inherited conditions globally, affect about 7% of the population as carriers, with 2.7% of newborns being born with these conditions. The spectrum of clinical manifestations... Read more

Immunology

view channel
Image: Exosomes can be a promising biomarker for cellular rejection after organ transplant (Photo courtesy of Nicolas Primola/Shutterstock)

Diagnostic Blood Test for Cellular Rejection after Organ Transplant Could Replace Surgical Biopsies

Transplanted organs constantly face the risk of being rejected by the recipient's immune system which differentiates self from non-self using T cells and B cells. T cells are commonly associated with acute... Read more

Microbiology

view channel
Image: The ePlex system has been rebranded as the cobas eplex system (Photo courtesy of Roche)

Enhanced Rapid Syndromic Molecular Diagnostic Solution Detects Broad Range of Infectious Diseases

GenMark Diagnostics (Carlsbad, CA, USA), a member of the Roche Group (Basel, Switzerland), has rebranded its ePlex® system as the cobas eplex system. This rebranding under the globally renowned cobas name... Read more

Pathology

view channel
Image: The revolutionary autonomous blood draw technology is witnessing growing demands (Photo courtesy of Vitestro)

Robotic Blood Drawing Device to Revolutionize Sample Collection for Diagnostic Testing

Blood drawing is performed billions of times each year worldwide, playing a critical role in diagnostic procedures. Despite its importance, clinical laboratories are dealing with significant staff shortages,... Read more