LabMedica

Download Mobile App
Recent News Expo Clinical Chem. Molecular Diagnostics Hematology Immunology Microbiology Pathology Technology Industry Focus

Liquid Biopsy Device Selectively Captures Circulating Tumor Cells

By LabMedica International staff writers
Posted on 12 Aug 2019
Print article
Image: A circulating cancer cell (pink) attaches to carbon nanotube surface; white blood cells (blue) do not adhere and are later washed away (Photo courtesy of Curtis Sayers).
Image: A circulating cancer cell (pink) attaches to carbon nanotube surface; white blood cells (blue) do not adhere and are later washed away (Photo courtesy of Curtis Sayers).
A new type of antigen-independent liquid biopsy captures device exploits the preferential attachment of circulating tumor cells (CTCs) to the surface of carbon nanotubes.

The nanotube-CTC-chip is a novel 76-element microarray that combined carbon nanotube surfaces with microarray batch manufacturing techniques for the capture and isolation of tumor-derived epithelial cells.

Investigators at the Worcester Polytechnic Institute (MA, USA) and several other institutions collaborated to prepare the chips by using materials and batch fabrication techniques similar to those used to make semiconductors. The current generation is configured as a 76-element array of test wells on a glass and silicon wafer. CTCs captured by the carbon nanotube chip remain viable and can be cultured. Furthermore, as the chips are transparent, it is possible to stain and study captured cells without removing them.

By combining lysis of red blood cells (RBC) with the carbon nanotube’s preferential adherence capabilities, the investigators demonstrated the capture and enrichment of CTCs with a five-log reduction of contaminating white blood cells (WBCs). Electron microscopy (EM) studies showed focal adhesion with filaments from the cell body to the nanotube surface.

The nanotube-CTC-chip successfully captured CTCs in the peripheral blood of breast cancer patients (stage 1–4) with a range of four to 238 CTCs per 8.5 millileters blood or 0.5–28 CTCs per milliliter. CTCs (based on CK8/18, Her2, and EGFR biomarkers) were successfully identified in seven out of seven breast cancer patients, and no CTCs were captured from two healthy controls. CTC enumeration based on multiple markers using the nanotube-CTC-chip enabled dynamic views of metastatic progression and could potentially have predictive capabilities for diagnosis and treatment response.

"Isolating CTCs with high purity is a significant challenge, akin to finding a needle in a haystack," said senior author Dr. Balaji Panchapakesan, professor of mechanical engineering at the Worchester Polytechnic Institute. "These cells comprise as few as one to 10 cells among a billion blood cells, and the shedding of CTCs from tumors is a highly discontinuous process."

"These initial clinical studies," said Dr. Panchapakesan, "in which we were able to capture and identify individual CTCs of varying phenotypes, show that this device could become an important tool not only for tracking the progression of cancers and their response to radiation or chemotherapy, but also in making predictions about the likely course of the cancer, which could help physicians identity the most effective course of therapy. This potentially life-saving technology could have multiple beneficial applications. It could help shed light on the complex biological and genetic processes at play in cancer. It could detect cancers at a very early stage by capturing the cells that nascent tumors shed into the blood. It could identify CTCs with metastatic potential before new tumors even begins, and it could help shape treatments customized to each person's cancer."

The nanotube-CTC-chip liquid biopsy device was described in the May 3, 2019, online edition of the journal Lab on a Chip.

Related Links:
Worcester Polytechnic Institute

Platinum Member
COVID-19 Rapid Test
OSOM COVID-19 Antigen Rapid Test
Magnetic Bead Separation Modules
MAG and HEATMAG
Anti-Cyclic Citrullinated Peptide Test
GPP-100 Anti-CCP Kit
Gold Member
ADAMTS-13 Protease Activity Test
ATS-13 Activity Assay

Print article

Channels

Clinical Chemistry

view channel
Image: The 3D printed miniature ionizer is a key component of a mass spectrometer (Photo courtesy of MIT)

3D Printed Point-Of-Care Mass Spectrometer Outperforms State-Of-The-Art Models

Mass spectrometry is a precise technique for identifying the chemical components of a sample and has significant potential for monitoring chronic illness health states, such as measuring hormone levels... Read more

Hematology

view channel
Image: The CAPILLARYS 3 DBS devices have received U.S. FDA 510(k) clearance (Photo courtesy of Sebia)

Next Generation Instrument Screens for Hemoglobin Disorders in Newborns

Hemoglobinopathies, the most widespread inherited conditions globally, affect about 7% of the population as carriers, with 2.7% of newborns being born with these conditions. The spectrum of clinical manifestations... Read more

Immunology

view channel
Image: The AI predictive model identifies the most potent cancer killing immune cells for use in immunotherapies (Photo courtesy of Shutterstock)

AI Predicts Tumor-Killing Cells with High Accuracy

Cellular immunotherapy involves extracting immune cells from a patient's tumor, potentially enhancing their cancer-fighting capabilities through engineering, and then expanding and reintroducing them into the body.... Read more

Microbiology

view channel
Image: The T-SPOT.TB test is now paired with the Auto-Pure 2400 liquid handling platform for accurate TB testing (Photo courtesy of Shutterstock)

Integrated Solution Ushers New Era of Automated Tuberculosis Testing

Tuberculosis (TB) is responsible for 1.3 million deaths every year, positioning it as one of the top killers globally due to a single infectious agent. In 2022, around 10.6 million people were diagnosed... Read more