We use cookies to understand how you use our site and to improve your experience. This includes personalizing content and advertising. To learn more, click here. By continuing to use our site, you accept our use of cookies. Cookie Policy.

LabMedica

Download Mobile App
Recent News Expo Clinical Chem. Molecular Diagnostics Hematology Immunology Microbiology Pathology Technology Industry Focus

Ion-Selective Electrode Methods Compared for Electrolytes

By LabMedica International staff writers
Posted on 02 Jul 2019
Print article
Image: The RAPIDPoint 500 Blood Gas System delivers fast, accurate and comprehensive test results for whole blood samples in approximately 60 seconds (Photo courtesy of Siemens Healthineers).
Image: The RAPIDPoint 500 Blood Gas System delivers fast, accurate and comprehensive test results for whole blood samples in approximately 60 seconds (Photo courtesy of Siemens Healthineers).
Electrolytes are among the most commonly requested clinical laboratory tests. There are two methods for measuring electrolytes in plasma, both using the principle of an ion-selective electrode (ISE).

The first method, used in point-of-care blood gas analyzers, is direct potentiometry, which measures electrolyte activity in plasma without dilution. The second method, used in routine chemistry analyzers in central laboratories, is indirect ISE, which involves a pre-analytical serum or plasma dilution step.

Clinical biochemists at the Leiden University Medical Center (Leiden, The Netherlands) and their colleagues used anonymized laboratory results of patients admitted to the emergency room and intensive care unit, and demonstrated in four steps that this lack of interchangeability of sodium and chloride results can be attributed to differences in measurement principle, but also to analytical standardization issues of the blood gas analyzers.

The team extracted blood gas results performed on a RAPIDPoint 500 and routine chemistry performed on a Modular P800 sodium and chloride results for patients admitted to the emergency room of their hospital between June 1, 2014, and May 17, 2016.

The team investigated the effects of the introduction of the instrument factors in the blood gas analysers, by extracting blood gas and routine chemistry sodium and chloride results (with a maximum time of 1 hour between sample analysis) again for patients admitted to the emergency room of our hospital. This approach eliminated the systematic differences between blood gas and serum sodium for 92 emergency department patients, and reduced the mean difference in chloride to 1 mmol/L for 25 patients. The mean difference in sodium results between blood gas and serum for intensive care patients decreased from 4 mmol/L to 2 mmol/L.

The authors concluded that standardization of sodium and chloride across methods and matrices is not a simple task and emphasizes the need for a close collaboration between laboratory specialists and clinicians regarding education on pitfalls in laboratory medicine. The study was published on June 13, 2019, in the journal Practical Laboratory Medicine.

Related Links:
Leiden University Medical Center

Platinum Member
COVID-19 Rapid Test
OSOM COVID-19 Antigen Rapid Test
Magnetic Bead Separation Modules
MAG and HEATMAG
Complement 3 (C3) Test
GPP-100 C3 Kit
New
Gold Member
Plasma Control
Plasma Control Level 1

Print article

Channels

Molecular Diagnostics

view channel
Image: The new blood test identifies key biomarkers of osteoarthritis (Photo courtesy of Shutterstock)

Blood Test Predicts Knee Osteoarthritis Eight Years Before Signs Appears On X-Rays

Osteoarthritis (OA) is the most prevalent form of arthritis, impacting millions worldwide and resulting in significant economic and social costs. Although no cure exists currently, the effectiveness of... Read more

Hematology

view channel
Image: The CAPILLARYS 3 DBS devices have received U.S. FDA 510(k) clearance (Photo courtesy of Sebia)

Next Generation Instrument Screens for Hemoglobin Disorders in Newborns

Hemoglobinopathies, the most widespread inherited conditions globally, affect about 7% of the population as carriers, with 2.7% of newborns being born with these conditions. The spectrum of clinical manifestations... Read more

Immunology

view channel
Image: Exosomes can be a promising biomarker for cellular rejection after organ transplant (Photo courtesy of Nicolas Primola/Shutterstock)

Diagnostic Blood Test for Cellular Rejection after Organ Transplant Could Replace Surgical Biopsies

Transplanted organs constantly face the risk of being rejected by the recipient's immune system which differentiates self from non-self using T cells and B cells. T cells are commonly associated with acute... Read more

Pathology

view channel
Image: The Sampler device could revolutionize sample collection for diagnostic tests (Photo courtesy of ReadyGo Diagnostics)

First of Its Kind Universal Tool to Revolutionize Sample Collection for Diagnostic Tests

The COVID pandemic has dramatically reshaped the perception of diagnostics. Post the pandemic, a groundbreaking device that combines sample collection and processing into a single, easy-to-use disposable... Read more