We use cookies to understand how you use our site and to improve your experience. This includes personalizing content and advertising. To learn more, click here. By continuing to use our site, you accept our use of cookies. Cookie Policy.

LabMedica

Download Mobile App
Recent News Expo Clinical Chem. Molecular Diagnostics Hematology Immunology Microbiology Pathology Technology Industry Focus

C-Peptide Test Essential after Type 1 Diabetes Diagnosis

By LabMedica International staff writers
Posted on 03 Apr 2019
Print article
Image: The Architect I2000sr immunoassay (Photo courtesy of Abbott).
Image: The Architect I2000sr immunoassay (Photo courtesy of Abbott).
C-peptide testing a few years after a diagnosis of type 1 diabetes should be a routine procedure as it can help pinpoint occasional patients who have been misdiagnosed and actually have type 2 diabetes or a monogenic form of the disease.

C-peptide testing is a means of determining patients' endogenous insulin levels and was once routinely used in type 1 diabetes diagnoses until it was realized that there is often a 'honeymoon period' during which patients still have residual beta-cell activity, making the test outcome a little unreliable.

Scientists at the Western General Hospital (Edinburgh, UK) introduced routine serum C‐peptide testing using ARCHITECT immunoassay in their center for patients with a clinician diagnosis of Type 1 diabetes of at least three years’ duration. C‐peptide equal to or greater than 200 pmol/L prompted evaluation for other causes of diabetes.

Of 637 people tested, 548 (86%) had C‐peptide less than 200 pmol/L, consistent with a diagnosis of Type 1 diabetes. Eighty‐nine patients (14%) had C‐peptide equal to or greater than 200 pmol/L. Eleven patients had C‐peptide greater than 900 pmol/L with negative autoantibodies and their diagnosis was revised to type 2 diabetes. The team reported that five patients have switched from insulin to alternative anti‐diabetic therapy.

Eighteen patients had C‐peptide 600 to 900 pmol/L. Of these, six patients had at least one positive autoantibody and were all considered to have Type 1 diabetes. One of these individuals has discontinued insulin and was managed on oral anti‐diabetic therapy. Ten had negative autoantibodies, of who six were considered to have Type 2 diabetes. One patient had a HNF1α mutation and has discontinued insulin. Sixty patients had C‐peptide 200 to 600 pmol/L. Twenty‐eight patients had positive autoantibodies, while 22 had negative autoantibodies; one patient had mitochondrial diabetes and two had a HNF4α gene mutation.

Andrew Hattersley, MD, CBE, who presented the study, said, “If you transfer the blood on EDTA plasma it lasts for 24 hours. All samples that might be taken for HbA1c can also actually be used to measure C-peptide now. The sample can be taken randomly in the nonfasting state. Data has shown the only thing that matters is that the patient shouldn't be hypoglycemic, nor do patients need to be taken off their insulin treatment because we have tested that too and it made minimal difference to the C-peptide measurement.” The study was presented on March 7, 2019, at the Diabetes UK Professional Conference (DUPC) held in Liverpool, UK.

Related Links:
Western General Hospital

Platinum Member
COVID-19 Rapid Test
OSOM COVID-19 Antigen Rapid Test
Magnetic Bead Separation Modules
MAG and HEATMAG
POCT Fluorescent Immunoassay Analyzer
FIA Go
Gold Member
Fully Automated Cell Density/Viability Analyzer
BioProfile FAST CDV

Print article

Channels

Molecular Diagnostics

view channel
Image: Ultrasound-based duplex sonography combined with a new genetic testing procedure can identify clonal haematopoiesis (Photo courtesy of 123RF)

New Genetic Testing Procedure Combined With Ultrasound Detects High Cardiovascular Risk

A key interest area in cardiovascular research today is the impact of clonal hematopoiesis on cardiovascular diseases. Clonal hematopoiesis results from mutations in hematopoietic stem cells and may lead... Read more

Hematology

view channel
Image: The CAPILLARYS 3 DBS devices have received U.S. FDA 510(k) clearance (Photo courtesy of Sebia)

Next Generation Instrument Screens for Hemoglobin Disorders in Newborns

Hemoglobinopathies, the most widespread inherited conditions globally, affect about 7% of the population as carriers, with 2.7% of newborns being born with these conditions. The spectrum of clinical manifestations... Read more

Immunology

view channel
Image: Exosomes can be a promising biomarker for cellular rejection after organ transplant (Photo courtesy of Nicolas Primola/Shutterstock)

Diagnostic Blood Test for Cellular Rejection after Organ Transplant Could Replace Surgical Biopsies

Transplanted organs constantly face the risk of being rejected by the recipient's immune system which differentiates self from non-self using T cells and B cells. T cells are commonly associated with acute... Read more

Pathology

view channel
Image: The Aperio GT 450 DX has received US FDA 510(k) clearance (Photo courtesy of Leica Biosystems)

Use of DICOM Images for Pathology Diagnostics Marks Significant Step towards Standardization

Digital pathology is rapidly becoming a key aspect of modern healthcare, transforming the practice of pathology as laboratories worldwide adopt this advanced technology. Digital pathology systems allow... Read more