We use cookies to understand how you use our site and to improve your experience. This includes personalizing content and advertising. To learn more, click here. By continuing to use our site, you accept our use of cookies. Cookie Policy.

LabMedica

Download Mobile App
Recent News Expo Clinical Chem. Molecular Diagnostics Hematology Immunology Microbiology Pathology Technology Industry Focus

Vitamin D Measured in Human Hair

By LabMedica International staff writers
Posted on 05 Mar 2019
Print article
Image: The API 4000 liquid-chromatography mass spectrometry system (Photo courtesy of SCIEX).
Image: The API 4000 liquid-chromatography mass spectrometry system (Photo courtesy of SCIEX).
Vitamin D deficiency has reached epidemic proportions worldwide, with over one billion people estimated to be affected. Deficiency has been linked with bone health, but it could also be a risk factor for depression, cardiovascular disease, inflammation, diabetes and cancer.

Blood result represents vitamin D status at a single time point, which is problematic because vitamin D changes with the seasons: it's not uncommon for someone to be sufficient in vitamin D in the summer time, and very deficient in the winter. This means that a single snapshot of vitamin D status is not able to provide information on vitamin D year-round.

A team of scientists collaborating with Trinity College Dublin (Dublin, Ireland) in a proof-of-concept study set out to provide evidence that 25-hydroxyvitamin D (25(OH)D3) can be extracted from hair samples in a similar fashion to steroid hormones. Two of the authors provided hair samples harvested from the crown area of the scalp and the third author provided beard samples. These samples were cut into 1 cm lengths, weighed, washed and dried. 25(OH)D was extracted using a previously published steroid hormones extraction procedure. Blood samples were taken from the subjects at the same time all samples were analyzed using the API 4000 liquid-chromatography mass spectrometry system.

The team reported that the hair samples showed presence of quantifiable 25(OH)D3 with concentrations ranging from 11.9–911 pg/mg. The beard sample had a concentration of 231 pg/mg. Serum levels of 25(OH)D3 ranged from 72 to 78 nmol/L. The results confirmed the feasibility of measuring 25(OH)D3 in hair samples. They noted that traditional blood analysis captures just a moment in time; in contrast, hair, which grows at approximately 1cm per month, could reflect vitamin D status over several months capturing the large seasonal differences in vitamin D status.

Lina Zgaga, PhD, an Associate Professor and lead author of the study, said, “This study presents the first step towards the development of a novel test for assessing vitamin D status over time. The idea is that vitamin D is being deposited continuously in the hair as it grows; more might be deposited at times when vitamin D concentration in the blood is high, and less when it's low. Therefore, test based on the hair sample might be able to give doctors a measure of vitamin D status over time, if hair is long enough, this even might be over a few years!” The study was published on February 18, 2019, in the journal Nutrients.

Related Links:
Trinity College Dublin

Platinum Member
COVID-19 Rapid Test
OSOM COVID-19 Antigen Rapid Test
Magnetic Bead Separation Modules
MAG and HEATMAG
POCT Fluorescent Immunoassay Analyzer
FIA Go
Gold Member
Systemic Autoimmune Testing Assay
BioPlex 2200 ANA Screen with MDSS

Print article

Channels

Molecular Diagnostics

view channel
Image: Researchers have found a way to spot the debilitating disease Alzheimer\'s before it develops into dementia (Photo courtesy of 123RF)

Advanced Blood Test to Spot Alzheimer's Before Progression to Dementia

Alzheimer’s disease is well known for its slow development over many years, which typically leads to treatment interventions only after the disease has advanced to stages where it may be nearly impossible... Read more

Hematology

view channel
Image: The CAPILLARYS 3 DBS devices have received U.S. FDA 510(k) clearance (Photo courtesy of Sebia)

Next Generation Instrument Screens for Hemoglobin Disorders in Newborns

Hemoglobinopathies, the most widespread inherited conditions globally, affect about 7% of the population as carriers, with 2.7% of newborns being born with these conditions. The spectrum of clinical manifestations... Read more

Immunology

view channel
Image: Exosomes can be a promising biomarker for cellular rejection after organ transplant (Photo courtesy of Nicolas Primola/Shutterstock)

Diagnostic Blood Test for Cellular Rejection after Organ Transplant Could Replace Surgical Biopsies

Transplanted organs constantly face the risk of being rejected by the recipient's immune system which differentiates self from non-self using T cells and B cells. T cells are commonly associated with acute... Read more

Microbiology

view channel
Image: The T-SPOT.TB test is now paired with the Auto-Pure 2400 liquid handling platform for accurate TB testing (Photo courtesy of Shutterstock)

Integrated Solution Ushers New Era of Automated Tuberculosis Testing

Tuberculosis (TB) is responsible for 1.3 million deaths every year, positioning it as one of the top killers globally due to a single infectious agent. In 2022, around 10.6 million people were diagnosed... Read more

Pathology

view channel
Image: The new method is quick and easy, and can also be used by non-medical personnel. (Photo courtesy of Zoratto et al. Advanced Science 2024, edited)

New Blood Test Device Modeled on Leeches to Help Diagnose Malaria

Many individuals have a fear of needles, making the experience of having blood drawn from their arm particularly distressing. An alternative method involves taking blood from the fingertip or earlobe,... Read more