Fructosamine Reference Range Established for Brazil
By LabMedica International staff writers Posted on 14 Jan 2019 |
Image: The AU 5800 automatic analyzer (Photo courtesy of Beckman Coulter).
Traditional markers used in diabetes diagnosis and monitoring include fasting plasma glucose (FPG), two-hour plasma glucose (2-hPG) measured during the oral glucose tolerance test (OGTT), and glycated hemoglobin (HbA1c) levels.
The fructosamine test is used in the monitoring of diabetes mellitus, particularly in cases with restrictions on the use of glycated hemoglobin, mainly in the setting of altered red blood cell lifespan and interference by hemoglobin variants. It could also provide additional information on shorter-term glycemic control.
Scientists at the Federal University of Minas Gerais, (Belo Horizonte, Brazil) collected blood samples from 2,288, that were part of a comprehensive study and available for fructosamine testing. The team excluded from the study individuals with a previous history of diabetes (n = 161), with FPG ≥ 5.6 mmol/L (100 mg/dL) and/or 2-hPG ≥ 7.8 mmol/L (140 mg/dL) and/or HbA1c ≥ 38.8 mmol/mol, (5.7%). They also excluded individuals with microalbuminuria ≥ 20 μg/min and creatinine> 114.9 µmol/L (1.3 mg/dL).
Samples were collected after a 12-h fasting period. The OGTT was conducted in all participants included in the present study. Samples were stored at −80 °C. Serum fructosamine levels were determined by the colorimetric nitroblue tetrazolium method in an AU 5800 automatic analyzer. The scientists proposed that the reference interval should be 186 to 248 μmol/L for women and 196 to 269 μmol/L for men. Fructosamine levels were higher in men than in women and in the non-white population and had a negative correlation with the body mass index.
The authors concluded that their study represents the first effort to establish a reference range for fructosamine levels in the Brazilian population. The report, which used the ELSA-Brazil baseline as a source of data, might contribute to future work on the diagnosis and monitoring of diabetes mellitus (DM), especially in situations when HbA1c and OGTT cannot be used. The study was published in the January 2019 issue of the journal Practical Laboratory Medicine.
Related Links:
Federal University of Minas Gerais
The fructosamine test is used in the monitoring of diabetes mellitus, particularly in cases with restrictions on the use of glycated hemoglobin, mainly in the setting of altered red blood cell lifespan and interference by hemoglobin variants. It could also provide additional information on shorter-term glycemic control.
Scientists at the Federal University of Minas Gerais, (Belo Horizonte, Brazil) collected blood samples from 2,288, that were part of a comprehensive study and available for fructosamine testing. The team excluded from the study individuals with a previous history of diabetes (n = 161), with FPG ≥ 5.6 mmol/L (100 mg/dL) and/or 2-hPG ≥ 7.8 mmol/L (140 mg/dL) and/or HbA1c ≥ 38.8 mmol/mol, (5.7%). They also excluded individuals with microalbuminuria ≥ 20 μg/min and creatinine> 114.9 µmol/L (1.3 mg/dL).
Samples were collected after a 12-h fasting period. The OGTT was conducted in all participants included in the present study. Samples were stored at −80 °C. Serum fructosamine levels were determined by the colorimetric nitroblue tetrazolium method in an AU 5800 automatic analyzer. The scientists proposed that the reference interval should be 186 to 248 μmol/L for women and 196 to 269 μmol/L for men. Fructosamine levels were higher in men than in women and in the non-white population and had a negative correlation with the body mass index.
The authors concluded that their study represents the first effort to establish a reference range for fructosamine levels in the Brazilian population. The report, which used the ELSA-Brazil baseline as a source of data, might contribute to future work on the diagnosis and monitoring of diabetes mellitus (DM), especially in situations when HbA1c and OGTT cannot be used. The study was published in the January 2019 issue of the journal Practical Laboratory Medicine.
Related Links:
Federal University of Minas Gerais
Latest Clinical Chem. News
- 3D Printed Point-Of-Care Mass Spectrometer Outperforms State-Of-The-Art Models
- POC Biomedical Test Spins Water Droplet Using Sound Waves for Cancer Detection
- Highly Reliable Cell-Based Assay Enables Accurate Diagnosis of Endocrine Diseases
- New Blood Testing Method Detects Potent Opioids in Under Three Minutes
- Wireless Hepatitis B Test Kit Completes Screening and Data Collection in One Step
- Pain-Free, Low-Cost, Sensitive, Radiation-Free Device Detects Breast Cancer in Urine
- Spit Test Detects Breast Cancer in Five Seconds
- Electrochemical Sensors with Next-Generation Coating Advances Precision Diagnostics at POC
- First-Of-Its-Kind Handheld Device Accurately Detects Fentanyl in Urine within Seconds
- New Fluorescent Sensor Array Lights up Alzheimer’s-Related Proteins for Earlier Detection
- Automated Mass Spectrometry-Based Clinical Analyzer Could Transform Lab Testing
- Highly Sensitive pH Sensor to Aid Detection of Cancers and Vector-Borne Viruses
- Non-Invasive Sensor Monitors Changes in Saliva Compositions to Rapidly Diagnose Diabetes
- Breakthrough Immunoassays to Aid in Risk Assessment of Preeclampsia
- Urine Test for Monitoring Changes in Kidney Health Markers Can Predict New-Onset Heart Failure
- AACC Releases Comprehensive Diabetes Testing Guidelines