We use cookies to understand how you use our site and to improve your experience. This includes personalizing content and advertising. To learn more, click here. By continuing to use our site, you accept our use of cookies. Cookie Policy.

LabMedica

Download Mobile App
Recent News Expo Clinical Chem. Molecular Diagnostics Hematology Immunology Microbiology Pathology Technology Industry Focus

Commercial Fully Automated Procalcitonin Immunoassay Compared

By LabMedica International staff writers
Posted on 04 Dec 2018
Print article
Image: The ARCHITECT B.R.A.H.M.S PCT assay, which is a two-step immunoassay using chemiluminescent microparticle immunoassay (CMIA) technology (Photo courtesy of Abbott Laboratories).
Image: The ARCHITECT B.R.A.H.M.S PCT assay, which is a two-step immunoassay using chemiluminescent microparticle immunoassay (CMIA) technology (Photo courtesy of Abbott Laboratories).
Procalcitonin (PCT), a 13-kDa peptide precursor of calcitonin, has gained widespread acceptance as an early and specific biomarker for the presence of systemic bacterial infection. In particular, PCT monitoring has demonstrated value in guiding antibiotic use for bacterial infections.

Based on high plasma levels of PCT during systemic bacterial and fungal infections that decrease on recovery and low concentrations during infections of viral origin or nonspecific causes, the use of PCT assays can be used to assist the clinical management of different patient groups in a range of clinical settings.

An international team of scientists working with the Abbott Laboratories (Abbott Park, IL, USA) using de-identified 1,116 plasma or serum samples from patients tested at nine clinical laboratories in Australia, France, Germany, Italy, South Africa, Turkey, Vietnam and Wales. Plasma or serum samples were tested either fresh or following storage of the serum fraction at 2–8 °C for a maximum of 24 hours.

The team evaluated the ARCHITECT B.R.A.H.M.S PCT assay, which is a two-step immunoassay using chemiluminescent microparticle immunoassay (CMIA) technology, with a 29-minute assay completion time. The ARCHITECT B.R.A.H.M.S PCT assay was evaluated on Abbott Laboratories’ ARCHITECT i2000SR immunoanalyzers. The ARCHITECT B.R.A.H.M.S PCT assay was compared with the Roche Cobas (Basel, Switzerland), Diasorin LIAISON (Saluggia, Italy); bioMérieux VIDAS (‎Marcy-l'Étoile, France), and widely accepted B.R.A.H.M.S Kryptor systems (Hennigsdorf, Germany).

The scientists reported that using Deming regression analysis of the plasma or serum samples with PCT results detected across a dynamic assay range of 0.02–100 μg/L using the ARCHITECT B.R.A.H.M.S PCT assay yielded results of r = 0.989 versus. Roche Cobas, r = 0.986 versus Kryptor B.R.A.H.M.S, r = 0.987 versus BioMérieux VIDAS and r = 0.972 versus Diasorin LIAISON respectively. Concordance at cut-offs of 0.25 μg/L and 0.50 μg/L were 96.9% and 98.1% with Roche Cobas, 95.4% and 96.1% with B.R.A.H.M.S Kryptor, 93.8% and 98.4% with bioMérieux VIDAS, and 92.7% and 93.9% with Diasorin LIAISON.

The authors concluded that independent observations at nine different clinical laboratory sites confirmed the analytical characteristics of the ARCHITECT B.R.A.H.M.S PCT immunoassay. Compared with other assays, ARCHITECT B.R.A.H.M.S PCT offers excellent precision and low-end sensitivity. The study was published on November 9, 2018, in the journal Practical Laboratory Medicine.

Platinum Member
COVID-19 Rapid Test
OSOM COVID-19 Antigen Rapid Test
Magnetic Bead Separation Modules
MAG and HEATMAG
Anti-Cyclic Citrullinated Peptide Test
GPP-100 Anti-CCP Kit
Gold Member
Real-time PCR System
GentierX3 Series

Print article

Channels

Molecular Diagnostics

view channel
Image: Ultrasound-based duplex sonography combined with a new genetic testing procedure can identify clonal haematopoiesis (Photo courtesy of 123RF)

New Genetic Testing Procedure Combined With Ultrasound Detects High Cardiovascular Risk

A key interest area in cardiovascular research today is the impact of clonal hematopoiesis on cardiovascular diseases. Clonal hematopoiesis results from mutations in hematopoietic stem cells and may lead... Read more

Hematology

view channel
Image: The CAPILLARYS 3 DBS devices have received U.S. FDA 510(k) clearance (Photo courtesy of Sebia)

Next Generation Instrument Screens for Hemoglobin Disorders in Newborns

Hemoglobinopathies, the most widespread inherited conditions globally, affect about 7% of the population as carriers, with 2.7% of newborns being born with these conditions. The spectrum of clinical manifestations... Read more

Immunology

view channel
Image: Exosomes can be a promising biomarker for cellular rejection after organ transplant (Photo courtesy of Nicolas Primola/Shutterstock)

Diagnostic Blood Test for Cellular Rejection after Organ Transplant Could Replace Surgical Biopsies

Transplanted organs constantly face the risk of being rejected by the recipient's immune system which differentiates self from non-self using T cells and B cells. T cells are commonly associated with acute... Read more

Pathology

view channel
Image: The Aperio GT 450 DX has received US FDA 510(k) clearance (Photo courtesy of Leica Biosystems)

Use of DICOM Images for Pathology Diagnostics Marks Significant Step towards Standardization

Digital pathology is rapidly becoming a key aspect of modern healthcare, transforming the practice of pathology as laboratories worldwide adopt this advanced technology. Digital pathology systems allow... Read more