Coagulation Tests Affected by Sodium Citrate Concentration

By LabMedica International staff writers
Posted on 27 Aug 2018
Print article
Image: The STA COMPACT MAX 2 is a fully automated benchtop analyzer (Photo courtesy of Diagnostica Stago).
Image: The STA COMPACT MAX 2 is a fully automated benchtop analyzer (Photo courtesy of Diagnostica Stago).
Despite a high degree of standardization, coagulation tests largely depend on preanalytic factors. Apart from artifacts acquired during blood drawing and transportation, the in vitro anticoagulant used has a potential impact on the coagulation test result.

Usually, a 9:1 blood to sodium citrate ratio is used with a buffer range between 3.2% and 3.8%.The 3.2% buffered sodium citrate binds less assay-added calcium than 3.8% buffered sodium citrate, therefore clotting times tend to be shorter in 3.2% than 3.8% buffered sodium citrate. Although there are no exact data available, today 3.2% buffered citrate is widely used.

Medical Laboratory Scientists at the Medical University of Vienna (Vienna, Austria) carried out a prospective observational study with 76 volunteers, differences related to the citrate concentration were evaluated. For both buffer concentrations, reference range intervals were established. Using the same calibration settings, 3.2% and 3.8% buffered citrate samples were consecutively analyzed. The reagent-analyzer combinations were chosen with respect to measurement accuracy and validity, assays' robustness and practicability during the parameters' introduction phase at their laboratory.

The activated partial thromboplastin time lupus-sensitive reagent (aPTT-LA) for lupus anticoagulant (LAC) confirmation testing was analyzed by using plasma with and without a reagent containing phosphatidylethanolamine. Lupus anticoagulant confirmation testing was considered positive when the difference between both aPTT-LA clotting times was greater than eight seconds or the ratio between the neat diluted Russell viper venom time (dRVVT) and the dRVVTConfirm (dRVVTRatio, Staclot DRVV Screen/Staclot DRVV Confirm) was greater than 1.25.

The team found that most parameters evaluated presented good comparability between citrated samples taken with 3.2% and 3.8% trisodium buffer. The ellagic acid containing activated partial thromboplastin time reagent (aPTT-FS) indicated a systemic and proportional difference between both buffer concentrations, leading to an alteration in its reference ranges. Further, a confirmation test for lupus anticoagulant assessment (Staclot LA) showed only a moderate correlation with a proportional deviation between both citrate concentrations. Further, a statistically significant difference was found in the diluted Russell viper venom time confirmation testing, coagulation factors V and VIII, and the protein C activity, which was found to be of minor clinical relevance.

The authors concluded that the alteration of 3.2% and 3.8% buffered sodium citrate on specialized coagulation tests in their setting was of limited relevance. As an exception, the aPTT-FS and aPTT-LADifference were significantly affected by the citrate concentration used. These findings demonstrate the comparability of data assessed with these citrate concentration ranges. The study was published in the August 2018 issue of the journal Archives of Pathology & Laboratory Medicine.

Related Links:
Medical University of Vienna

Platinum Member
COVID-19 Rapid Test
OSOM COVID-19 Antigen Rapid Test
Magnetic Bead Separation Modules
MAG and HEATMAG
Anti-Cyclic Citrullinated Peptide Test
GPP-100 Anti-CCP Kit
Gold Member
Fully Automated Cell Density/Viability Analyzer
BioProfile FAST CDV

Print article

Channels

Clinical Chemistry

view channel
Image: The 3D printed miniature ionizer is a key component of a mass spectrometer (Photo courtesy of MIT)

3D Printed Point-Of-Care Mass Spectrometer Outperforms State-Of-The-Art Models

Mass spectrometry is a precise technique for identifying the chemical components of a sample and has significant potential for monitoring chronic illness health states, such as measuring hormone levels... Read more

Molecular Diagnostics

view channel
Image: Researchers have found a way to spot the debilitating disease Alzheimer\'s before it develops into dementia (Photo courtesy of 123RF)

Advanced Blood Test to Spot Alzheimer's Before Progression to Dementia

Alzheimer’s disease is well known for its slow development over many years, which typically leads to treatment interventions only after the disease has advanced to stages where it may be nearly impossible... Read more

Immunology

view channel
Image: Exosomes can be a promising biomarker for cellular rejection after organ transplant (Photo courtesy of Nicolas Primola/Shutterstock)

Diagnostic Blood Test for Cellular Rejection after Organ Transplant Could Replace Surgical Biopsies

Transplanted organs constantly face the risk of being rejected by the recipient's immune system which differentiates self from non-self using T cells and B cells. T cells are commonly associated with acute... Read more

Microbiology

view channel
Image: The T-SPOT.TB test is now paired with the Auto-Pure 2400 liquid handling platform for accurate TB testing (Photo courtesy of Shutterstock)

Integrated Solution Ushers New Era of Automated Tuberculosis Testing

Tuberculosis (TB) is responsible for 1.3 million deaths every year, positioning it as one of the top killers globally due to a single infectious agent. In 2022, around 10.6 million people were diagnosed... Read more

Pathology

view channel
Image: The new method is quick and easy, and can also be used by non-medical personnel. (Photo courtesy of Zoratto et al. Advanced Science 2024, edited)

New Blood Test Device Modeled on Leeches to Help Diagnose Malaria

Many individuals have a fear of needles, making the experience of having blood drawn from their arm particularly distressing. An alternative method involves taking blood from the fingertip or earlobe,... Read more