Major Trauma Emergency Blood Transfusions Need Consistency

By LabMedica International staff writers
Posted on 16 Feb 2016
Print article
Image: Blood transfusion components that include red blood cells, plasma and other clotting products (Photo courtesy of the Australian Red Cross Service).
Image: Blood transfusion components that include red blood cells, plasma and other clotting products (Photo courtesy of the Australian Red Cross Service).
Globally, bleeding following injury is estimated to be responsible for over two million deaths per year and current treatment strategies focus on the rapid delivery of red blood cells, plasma and other clotting products.

Nearly 5,000 trauma patients sustain major hemorrhage in England and Wales each year and that one-third of those die and delays in blood transfusion practices may contribute to this high death rate. The logistics of providing the correct quantities in the right proportion during the first minutes and hours of emergency care can be extremely challenging.

A team of scientists led by those at the Queen Mary, University of London (London, UK) carried out a prospective observational study from 22 hospitals in the UK, including both major trauma centers and smaller trauma units. Eligible patients received at least four units of packed red blood cells (PRBCs) in the first 24 hours of admission with activation of the massive hemorrhage protocol. The study outcomes were the use of blood components, critical care during hospital stay, and mortality at 24 hours, 30 days and one year.

Overall, only 2% of all patients with massive hemorrhage received what might be considered the optimal transfusion of a high dose of clotting products in conjunction with red blood cells during the first hour of arrival within the Emergency Department. The average time to transfusion of red blood cells was longer than expected, at 41 minutes. Administration of specific blood components to aid with blood clotting such as plasma, platelets and cryoprecipitate was significantly delayed, occurring on average 2-3 hours after admission.

Mortality from bleeding tended to occur early, with nearly two-thirds of all deaths in the first 24 hours. An unexpectedly high number of deaths (7.9%) occurred once the patient left hospital, the reasons for which were unclear. The incidence of major hemorrhage increased markedly in patients over 65 years, who were twice as likely to suffer massive hemorrhage as a result of an injury compared to younger groups. Patients who received a cumulative ratio of fresh frozen plasma to PRBCs of at least 1:2 had lower rates of death than those who received a lower ratio. There were delays in administration of blood. Platelets and cryoprecipitate were either not given, or transfused well after initial resuscitation.

Karim Brohi, MD, a professor of Trauma Surgery and senior author of the study said, “Bleeding is the leading cause of preventable death in trauma. The rapid and consistent delivery of blood, plasma, platelets and other clotting products to trauma patients is essential to maintain clotting during hemorrhage and has been shown to halve mortality. However, we found that only 2% of patients with massive hemorrhage received the optimal type of blood transfusion for their resuscitation. There is a clear opportunity for clinicians to improve the delivery of blood and clotting products during resuscitation for major hemorrhage.” The study was published on February 3, 2016, in the British Journal of Surgery.

Related Links:

Queen Mary, University of London 


Platinum Member
COVID-19 Rapid Test
OSOM COVID-19 Antigen Rapid Test
Magnetic Bead Separation Modules
MAG and HEATMAG
POCT Fluorescent Immunoassay Analyzer
FIA Go
New
Gold Member
TORCH Panel Rapid Test
Rapid TORCH Panel Test

Print article

Channels

Clinical Chemistry

view channel
Image: The 3D printed miniature ionizer is a key component of a mass spectrometer (Photo courtesy of MIT)

3D Printed Point-Of-Care Mass Spectrometer Outperforms State-Of-The-Art Models

Mass spectrometry is a precise technique for identifying the chemical components of a sample and has significant potential for monitoring chronic illness health states, such as measuring hormone levels... Read more

Immunology

view channel
Image: The AI predictive model identifies the most potent cancer killing immune cells for use in immunotherapies (Photo courtesy of Shutterstock)

AI Predicts Tumor-Killing Cells with High Accuracy

Cellular immunotherapy involves extracting immune cells from a patient's tumor, potentially enhancing their cancer-fighting capabilities through engineering, and then expanding and reintroducing them into the body.... Read more

Microbiology

view channel
Image: The T-SPOT.TB test is now paired with the Auto-Pure 2400 liquid handling platform for accurate TB testing (Photo courtesy of Shutterstock)

Integrated Solution Ushers New Era of Automated Tuberculosis Testing

Tuberculosis (TB) is responsible for 1.3 million deaths every year, positioning it as one of the top killers globally due to a single infectious agent. In 2022, around 10.6 million people were diagnosed... Read more