Iron Status Determined in Pregnancy Using the Thomas Plot

By LabMedica International staff writers
Posted on 12 Jan 2016
Print article
The Advia Centaur XP immunoassay system
The Advia Centaur XP immunoassay system (Photo courtesy of Siemens Healthineers - Laboratory Diagnostics)
Iron deficiency anemia (IDA) in pregnancy is common and associated with an increased risk for poor pregnancy outcomes, including intrauterine growth retardation, stillbirth, preterm delivery, low birthweight, and decreased survival of peripartum hemorrhage.

Physiological changes during pregnancy affect routine tests for iron deficiency. The reticulocyte hemoglobin equivalent (RET-He) and serum-soluble transferrin receptor (sTfR) assay are newer diagnostic parameters for the detection of iron deficiency, combined in the Thomas diagnostic plot.

Hematologists at the University of the Free State (Bloemfontein, South Africa) recruited for a study 103 participants, ranging between 18 and 42 years in age (median 24 years), and 50 were primigravidae. The gestation at which they presented for their first antenatal visit varied greatly from five to 36 week and the median gestational age was 18 weeks. Most of the participants (61.1%) were in their second trimester of pregnancy (13- to 28-week gestation) and 32% of participants were human immunodeficiency virus (HIV)-positive.

A full blood count (FBC) with reticulocyte parameters (RET-He) was performed using the Sysmex XE-2100 analyzer (Sysmex Corporation; Kobe, Japan). Serum ferritin was measured on the Advia Centaur XP immunoassay system (Siemens Healthcare Diagnostics Inc.; Tarrytown, NY, USA). The sTfR was determined using the Siemens subsidiary Dade Behring N Latex sTfR kit on a Siemens BN Prospec System nephelometer, and the C-reactive protein (CRP) was measured using the Synchron LX20 instrument and Synchron CRP reagent kit (Beckman Coulter; Fullerton, CA, USA).

The scientists found that according to the Thomas plot, 72.8% of the participants had normal iron stores and erythropoiesis. Iron-deficient erythropoiesis was detected in 12.6%. A third of participants were anemic. Serum ferritin showed excellent sensitivity but poor specificity for detecting depleted iron stores. Participants in their first trimester of pregnancy were less likely to have iron-deficient erythropoiesis and functional iron deficiency than participants in the third trimester. HIV status had no influence on the iron status of the participants.

The authors concluded that their findings reiterate that causes other than iron deficiency should be considered in anemic individuals. When compared with the Thomas plot, a low serum ferritin is a sensitive but nonspecific indicator of iron deficiency. The Thomas plot may provide useful information to identify pregnant individuals in whom hematological parameters indicate limited iron availability for erythropoiesis. The study was first published online on November 14, 2015, in the International Journal of Laboratory Hematology.

Related Links:

University of the Free State 
Sysmex Corporation 
Siemens Healthcare Diagnostics Inc. 


Platinum Member
COVID-19 Rapid Test
OSOM COVID-19 Antigen Rapid Test
Magnetic Bead Separation Modules
MAG and HEATMAG
Anti-Cyclic Citrullinated Peptide Test
GPP-100 Anti-CCP Kit
New
Gold Member
Liquid Ready-To-Use Lp(a) Reagent
Lipoprotein (a) Reagent
Read the full article by registering today, it's FREE! It's Free!
Register now for FREE to LabMedica.com and get complete access to news and events that shape the world of Clinical Laboratory Medicine.
  • Free digital version edition of LabMedica International sent by email on regular basis
  • Free print version of LabMedica International magazine (available only outside USA and Canada).
  • Free and unlimited access to back issues of LabMedica International in digital format
  • Free LabMedica International Newsletter sent every week containing the latest news
  • Free breaking news sent via email
  • Free access to Events Calendar
  • Free access to LinkXpress new product services
  • REGISTRATION IS FREE AND EASY!
Click here to Register








Channels

Clinical Chemistry

view channel
Image: The 3D printed miniature ionizer is a key component of a mass spectrometer (Photo courtesy of MIT)

3D Printed Point-Of-Care Mass Spectrometer Outperforms State-Of-The-Art Models

Mass spectrometry is a precise technique for identifying the chemical components of a sample and has significant potential for monitoring chronic illness health states, such as measuring hormone levels... Read more

Immunology

view channel
Image: The AI predictive model identifies the most potent cancer killing immune cells for use in immunotherapies (Photo courtesy of Shutterstock)

AI Predicts Tumor-Killing Cells with High Accuracy

Cellular immunotherapy involves extracting immune cells from a patient's tumor, potentially enhancing their cancer-fighting capabilities through engineering, and then expanding and reintroducing them into the body.... Read more

Microbiology

view channel
Image: The T-SPOT.TB test is now paired with the Auto-Pure 2400 liquid handling platform for accurate TB testing (Photo courtesy of Shutterstock)

Integrated Solution Ushers New Era of Automated Tuberculosis Testing

Tuberculosis (TB) is responsible for 1.3 million deaths every year, positioning it as one of the top killers globally due to a single infectious agent. In 2022, around 10.6 million people were diagnosed... Read more