LabMedica

Download Mobile App
Recent News Expo Clinical Chem. Molecular Diagnostics Hematology Immunology Microbiology Pathology Technology Industry Focus

Magnetic Resonance Improves Approach to Measuring Hemostasis Parameters

By LabMedica International staff writers
Posted on 21 Jul 2015
Print article
Two studies evaluating a magnetic resonance based detector for hemostasis measurements found its multiplex results to be rapid and accurate using lower blood volumes.

At the International Society on Thrombosis and Hemostasis (ISTH) 2015 Congress (Toronto, Canada), T2 Biosystems, Inc. (Lexington, MA, USA) presented results of two investigational studies highlighting the capability of its T2 Magnetic Resonance (T2MR) detector to accurately and rapidly measure hemostasis parameters directly in whole blood. T2MR, a single easy-to-use instrument, demonstrated strong correlation to a current standard-of-care. It is suitable for applications such as point-of-care testing, drug development, animal studies, and biomarker discovery.

One study was “T2MR Platelet Analysis Correlates with Light Transmission Aggregometry (LTA) and Rapidly Reveals Unique Details of ADP-Mediated Platelet Activation in Whole Blood.” In this study, T2MR detected the most clinically valuable platelet parameters to provide an assessment of platelet activity in just 20 minutes using low blood volumes (0.04 mL of whole blood) while demonstrating 100% correlation to the current standard-of-care. "The current gold standard test for measuring platelet function requires specialized equipment and personnel, 20–30 mL of blood, takes several hours to provide results, and is most often a send-out test to a reference lab," said Douglas B. Cines, MD, professor of Pathology and Laboratory Medicine at the University of Pennsylvania’s medical school, "T2MR provides an opportunity to overcome these barriers to care using a more rapid and simple-to-use approach."

The second study was “Whole Blood Platelet Activity Measurements Multiplexed with Quantitative Fibrinogen, Clot Time and Fibrinolysis Measurements by T2MR.” Currently, there is no single solution for rapidly measuring the 4 critical measures of coagulation: clotting time, platelet function, fibrinogen, and fibrinolysis. In this study, T2MR was shown to rapidly (clot time and fibrinogen data detected within 3 minutes; platelet function within 20 minutes) and accurately assess (100% correlation to the standard-of-care) potential bleeding disorders through a single multiplex analysis of global hemostasis utilizing low blood volumes (0.035 mL whole blood). In addition, T2MR generated robust signatures that have led to the discovery of novel biomarkers that may potentially have other important clinical applications.

"We are very encouraged by these data and for T2MR to make a potentially critical difference in providing physicians with the accurate, timely hemostasis information needed to make important treatment decisions for patients," said John McDonough, CEO, T2 Biosystems, "In trauma, for example, research has shown that mortality in patients with symptoms of impaired hemostasis can be reduced from 45% to 19% with more rapid detection and delivery of treatment. We believe that T2MR has the potential to address a significant unmet need that can bring significant benefits to the health of patients and the cost of healthcare."

T2MR is a diagnostic detection method utilizing miniaturized magnetic resonance technology that measures how water molecules react in the presence of magnetic fields. It is highly sensitive to changes in the microenvironment of a blood sample, such as clot formation, contraction, and lysis. This enables rapid identification of clinically relevant hemostasis changes.

T2MR has currently not been cleared by the US Food and Drug Administration (FDA) for use in hemostasis.

Related Links:

T2 Biosystems, Inc.


Platinum Member
COVID-19 Rapid Test
OSOM COVID-19 Antigen Rapid Test
Magnetic Bead Separation Modules
MAG and HEATMAG
POCT Fluorescent Immunoassay Analyzer
FIA Go
Gold Member
Systemic Autoimmune Testing Assay
BioPlex 2200 ANA Screen with MDSS

Print article

Channels

Clinical Chemistry

view channel
Image: The 3D printed miniature ionizer is a key component of a mass spectrometer (Photo courtesy of MIT)

3D Printed Point-Of-Care Mass Spectrometer Outperforms State-Of-The-Art Models

Mass spectrometry is a precise technique for identifying the chemical components of a sample and has significant potential for monitoring chronic illness health states, such as measuring hormone levels... Read more

Immunology

view channel
Image: The AI predictive model identifies the most potent cancer killing immune cells for use in immunotherapies (Photo courtesy of Shutterstock)

AI Predicts Tumor-Killing Cells with High Accuracy

Cellular immunotherapy involves extracting immune cells from a patient's tumor, potentially enhancing their cancer-fighting capabilities through engineering, and then expanding and reintroducing them into the body.... Read more

Microbiology

view channel
Image: The T-SPOT.TB test is now paired with the Auto-Pure 2400 liquid handling platform for accurate TB testing (Photo courtesy of Shutterstock)

Integrated Solution Ushers New Era of Automated Tuberculosis Testing

Tuberculosis (TB) is responsible for 1.3 million deaths every year, positioning it as one of the top killers globally due to a single infectious agent. In 2022, around 10.6 million people were diagnosed... Read more