Childhood Hereditary Spherocytosis Confirmed by Hematology Analyzer

By LabMedica International staff writers
Posted on 25 Feb 2015
Print article
Image: The CELL-DYN Sapphire hematology analyzer (Photo courtesy of Abbott Diagnostics).
Image: The CELL-DYN Sapphire hematology analyzer (Photo courtesy of Abbott Diagnostics).
The hallmark of hereditary spherocytosis (HS) is a decreased surface area-to-volume ratio of the erythrocytes (RBC), resulting in the characteristic spherocyte form and in a blood film, spherocytes have a smaller diameter than normal RBC and are hyperchromic.


The flow cytometric eosin-5′-maleimide test (EMA) is highly sensitive and specific for HS as a confirmatory method and the utility of hyperchromic erythrocytes in HS screening and evaluation of the EMA test performed on a hematology analyzer was compared with the reference method.

Hematologists at Our Lady's Children's Hospital (Crumlin, Dublin, Ireland) analyzed blood samples from 740 pediatric patients presenting at their institution in the reticulocyte mode of the CELL-DYN Sapphire hematology analyzer (Abbott Diagnostics; Wiesbaden-Delkenheim, Germany) to obtain hyperchromic erythrocyte counts. The EMA test used as a reference for the laboratory diagnosis of HS was performed on a FACSCanto II flow cytometer (Becton Dickinson; San Jose, CA, USA).

Hyperchromic erythrocytes were the highest in patients with HS (median 11.5%; range 5.1 to 29.2%). Patients with autoimmune hemolytic disease had significantly less hyperchromic erythrocytes (median 4.9%; range 0.0 to 18.3%). Hyperchromic erythrocytes showed a high area under the receiver operating characteristic (ROC) curve of 0.972. At 4.9% cut-off, hyperchromic erythrocytes detected HS with 96.4% sensitivity and 99.1% specificity. The EMA test on CELL-DYN Sapphire correlated strongly with the reference test and had identical diagnostic power. Stability studies with blood from HS patients showed a significant decrease in hyperchromic erythrocytes after six hours of storage.

The authors concluded that measurement of hyperchromic erythrocytes is highly sensitive and specific for detecting HS and can be used for rapid and inexpensive screening. If required, the EMA test can be performed on the CELL-DYN Sapphire or a standard flow cytometer for confirmation of HS. The study was published in the February 2015 issue of the International Journal of Laboratory Hematology.

Related Links:

Our Lady's Children's Hospital 
Abbott Diagnostics 
Becton Dickinson


Platinum Member
COVID-19 Rapid Test
OSOM COVID-19 Antigen Rapid Test
Magnetic Bead Separation Modules
MAG and HEATMAG
Complement 3 (C3) Test
GPP-100 C3 Kit
Gold Member
Systemic Autoimmune Testing Assay
BioPlex 2200 ANA Screen with MDSS

Print article

Channels

Clinical Chemistry

view channel
Image: The 3D printed miniature ionizer is a key component of a mass spectrometer (Photo courtesy of MIT)

3D Printed Point-Of-Care Mass Spectrometer Outperforms State-Of-The-Art Models

Mass spectrometry is a precise technique for identifying the chemical components of a sample and has significant potential for monitoring chronic illness health states, such as measuring hormone levels... Read more

Immunology

view channel
Image: The AI predictive model identifies the most potent cancer killing immune cells for use in immunotherapies (Photo courtesy of Shutterstock)

AI Predicts Tumor-Killing Cells with High Accuracy

Cellular immunotherapy involves extracting immune cells from a patient's tumor, potentially enhancing their cancer-fighting capabilities through engineering, and then expanding and reintroducing them into the body.... Read more

Microbiology

view channel
Image: The T-SPOT.TB test is now paired with the Auto-Pure 2400 liquid handling platform for accurate TB testing (Photo courtesy of Shutterstock)

Integrated Solution Ushers New Era of Automated Tuberculosis Testing

Tuberculosis (TB) is responsible for 1.3 million deaths every year, positioning it as one of the top killers globally due to a single infectious agent. In 2022, around 10.6 million people were diagnosed... Read more