Hemoglobin Assay Performed with Photothermal Optical Sensor
By LabMedica International staff writers Posted on 11 Jan 2015 |
Image: Operating principle of the photothermal spectral-domain optical coherence reflectometer (PT SD-OCR) sensor for hemoglobin measurement (Photo image courtesy of Yonsei University).
An optical sensor, termed a photothermal spectral-domain optical coherence reflectometer (PT SD-OCR) is capable of direct measurement of hemoglobin concentration (Hb) without chemicals and preprocessing of blood.
The PT SD-OCR OCR measures Hb by quantifying refractive index changes of blood samples due to photothermal effect under the irradiation of 532-nm light and its diagnostic accuracy and precision has been evaluated in anemic patients.
Scientists at the Yonsei University (Seoul, Republic of Korea) and their colleagues used PT SD-OCR to measure Hb in 50 anemic patients, and examined its accuracy against a hematology analyzer. Its precision was assessed by examining the standard deviation (SD) and coefficients of variation (CV) based on 20 repeated measurements on three blood sample and its performance was also compared with a hemoglobinometer.
The relative accuracy of the PT SD-OCR sensor was examined and the comparisons of the PT SD-OCR and HemoCue 201+ System (Angelholm, Sweden) against the results from the ADVIA 2120i hematology analyze (Siemens AG, Erlangen, Germany). An excellent correlation was observed between the results from the hematology analyzer and those of the PT SD-OCR sensor. The precision of the PT SD-OCR sensor was also comparable with the ADVIA 2120i analyzer and the HemoCue 201+ detector.
The authors concluded that simple and chemical-free operation of PT SD-OCR enabled rapid and accurate measurement of Hb in anemic patients. The sensor is expected to facilitate clinical procedures related to blood-related disorders in patient care. The PT SD-OCR sensor may therefore be readily utilized in clinical settings for hemoglobin detection and determination of proper treatment strategies for anemic patients. The study was published in the January 2015 issue of the journal Clinica Chimica Acta.
Related Links:
Yonsei University
HemoCue
Siemens AG
The PT SD-OCR OCR measures Hb by quantifying refractive index changes of blood samples due to photothermal effect under the irradiation of 532-nm light and its diagnostic accuracy and precision has been evaluated in anemic patients.
Scientists at the Yonsei University (Seoul, Republic of Korea) and their colleagues used PT SD-OCR to measure Hb in 50 anemic patients, and examined its accuracy against a hematology analyzer. Its precision was assessed by examining the standard deviation (SD) and coefficients of variation (CV) based on 20 repeated measurements on three blood sample and its performance was also compared with a hemoglobinometer.
The relative accuracy of the PT SD-OCR sensor was examined and the comparisons of the PT SD-OCR and HemoCue 201+ System (Angelholm, Sweden) against the results from the ADVIA 2120i hematology analyze (Siemens AG, Erlangen, Germany). An excellent correlation was observed between the results from the hematology analyzer and those of the PT SD-OCR sensor. The precision of the PT SD-OCR sensor was also comparable with the ADVIA 2120i analyzer and the HemoCue 201+ detector.
The authors concluded that simple and chemical-free operation of PT SD-OCR enabled rapid and accurate measurement of Hb in anemic patients. The sensor is expected to facilitate clinical procedures related to blood-related disorders in patient care. The PT SD-OCR sensor may therefore be readily utilized in clinical settings for hemoglobin detection and determination of proper treatment strategies for anemic patients. The study was published in the January 2015 issue of the journal Clinica Chimica Acta.
Related Links:
Yonsei University
HemoCue
Siemens AG
Latest Hematology News
- Next Generation Instrument Screens for Hemoglobin Disorders in Newborns
- First 4-in-1 Nucleic Acid Test for Arbovirus Screening to Reduce Risk of Transfusion-Transmitted Infections
- POC Finger-Prick Blood Test Determines Risk of Neutropenic Sepsis in Patients Undergoing Chemotherapy
- First Affordable and Rapid Test for Beta Thalassemia Demonstrates 99% Diagnostic Accuracy
- Handheld White Blood Cell Tracker to Enable Rapid Testing For Infections
- Smart Palm-size Optofluidic Hematology Analyzer Enables POCT of Patients’ Blood Cells
- Automated Hematology Platform Offers High Throughput Analytical Performance
- New Tool Analyzes Blood Platelets Faster, Easily and Accurately
- First Rapid-Result Hematology Analyzer Reports Measures of Infection and Severity at POC
- Bleeding Risk Diagnostic Test to Reduce Preventable Complications in Hospitals
- True POC Hematology Analyzer with Direct Capillary Sampling Enhances Ease-of-Use and Testing Throughput
- Point of Care CBC Analyzer with Direct Capillary Sampling Enhances Ease-of-Use and Testing Throughput
- Blood Test Could Predict Outcomes in Emergency Department and Hospital Admissions
- Novel Technology Diagnoses Immunothrombosis Using Breath Gas Analysis
- Advanced Hematology System Allows Labs to Process Up To 119 Complete Blood Count Results per Hour
- Unique AI-Based Approach Automates Clinical Analysis of Blood Data