Optical Interferometry Assays Stored Erythrocyte Function

By LabMedica International staff writers
Posted on 16 Sep 2014
Print article
Image: The topography of a red blood cell as measured by the spatial light interference microscope (SLIM) optical technique. Though the cell keeps its shape as it ages, the membrane becomes less flexible (Photo courtesy of Prof. Gabriel Popescu).
Image: The topography of a red blood cell as measured by the spatial light interference microscope (SLIM) optical technique. Though the cell keeps its shape as it ages, the membrane becomes less flexible (Photo courtesy of Prof. Gabriel Popescu).
The effect of the storage on the erythrocyte membrane deformability and morphology has been investigated using optical interferometry which can image red blood cell (RBC) topography with nanometer sensitivity.

Stored red blood cells or erythrocytes undergo numerous biochemical, structural, and functional changes, commonly referred to as storage lesion and these changes can impede the ability of erythrocytes to perform their function and, as result, impact clinical outcomes in transfusion patients.

Scientists and engineers at the University of Illinois at Urbana-Champaign (Urbana, IL, USA) used as source for RBC samples, packed red cells from donors collected in anticoagulant and preservation solution through the apheresis technique. The samples, two O+ and two A+, were obtained from saved segments of blood tube which is routinely attached to the blood unit in blood banks and maintained at 4 °C for the entire measurement period.

A sample chamber was created by punching a hole in a double sided scotch tape and sticking one side of the tape onto a poly-l-lysine coated cover slip (Neuvitro; El Monte, CA, USA). The sample is then pipetted into the chamber created by the hole and is sealed on the top using another cover slip. RBCs are allowed to settle for 45 minutes on the poly-l-lysine coated cover slip in order to avoid any cell movement prior to fast RBC imaging. A spatial light interference microscope (SLIM) was used where the optical layout is essentially a 4f-telecentric system. The SLIM was designed as an add-on module to a commercial phase contrast microscope the Axio Observer Z1 (Carl Zeiss Microscopy GmbH, Jena, Germany). Fast phase images were continuously recorded at 10 frames per second.

The team discovered that their measurements revealed a lot of characteristics stay the same over time as the cells retain their shape, mass and hemoglobin content. However, the membranes become stiffer and less elastic as time goes by. This is important because the blood cells need to be flexible enough to travel through tiny capillaries and permeable enough for oxygen to pass through. Increased stiffness in stored discocytes may be associated with reduction in post-transfusion survival and accelerate removal of transfused cells from the circulation. Availability of this dynamic membrane function assay may allow optimization of storage solution for RBCs with the objective of not only maintaining a normal RBC morphology but also normal membrane functionality.

Krishna Tangella, MD, a professor of pathology and a coauthor of the study said, “The results of this study can have a wide variety of clinical applications. Functional data from red blood cells would help physicians determine when to give red-cell transfusions for patients with anemia. This study may help better utilization of red-cell transfusions, which will not only decrease healthcare costs but also increase the quality of care.” The study was published on September 5, 2014, in the journal Scientific Reports.

Related Links:

University of Illinois at Urbana-Champaign
Neuvitro
Carl Zeiss Microscopy 


Platinum Member
COVID-19 Rapid Test
OSOM COVID-19 Antigen Rapid Test
Magnetic Bead Separation Modules
MAG and HEATMAG
POCT Fluorescent Immunoassay Analyzer
FIA Go
Gold Member
Systemic Autoimmune Testing Assay
BioPlex 2200 ANA Screen with MDSS

Print article

Channels

Clinical Chemistry

view channel
Image: The 3D printed miniature ionizer is a key component of a mass spectrometer (Photo courtesy of MIT)

3D Printed Point-Of-Care Mass Spectrometer Outperforms State-Of-The-Art Models

Mass spectrometry is a precise technique for identifying the chemical components of a sample and has significant potential for monitoring chronic illness health states, such as measuring hormone levels... Read more

Immunology

view channel
Image: Exosomes can be a promising biomarker for cellular rejection after organ transplant (Photo courtesy of Nicolas Primola/Shutterstock)

Diagnostic Blood Test for Cellular Rejection after Organ Transplant Could Replace Surgical Biopsies

Transplanted organs constantly face the risk of being rejected by the recipient's immune system which differentiates self from non-self using T cells and B cells. T cells are commonly associated with acute... Read more

Microbiology

view channel
Image: The T-SPOT.TB test is now paired with the Auto-Pure 2400 liquid handling platform for accurate TB testing (Photo courtesy of Shutterstock)

Integrated Solution Ushers New Era of Automated Tuberculosis Testing

Tuberculosis (TB) is responsible for 1.3 million deaths every year, positioning it as one of the top killers globally due to a single infectious agent. In 2022, around 10.6 million people were diagnosed... Read more