Calibration First Vital Step to Reliable Lab Results

By LabMedica International staff writers
Posted on 04 Jun 2014
Print article
Image: Sarah Kee, Quality Control Scientific Consultant at Randox, has given a series of talks about the often overlooked importance of accurate calibration in providing reliable test results for patients (Photo courtesy of Randox).
Image: Sarah Kee, Quality Control Scientific Consultant at Randox, has given a series of talks about the often overlooked importance of accurate calibration in providing reliable test results for patients (Photo courtesy of Randox).
A quality control (QC) consultant has reemphasized the obvious but still often overlooked importance of performing high-quality calibrations to provide physicians and patients with accurate laboratory results.

Randox Laboratories (Antrim, Northern Ireland, UK) has called for greater laboratory focus on calibration as the first and vital step to providing quality test results. In a recent multi-location series of QC talks, Sarah Kee, QC Scientific Consultant at Randox, noted that the importance of calibration is often overlooked and stressed that accurate calibration is the foundation for producing reliable results for patients. She added that as the first step in assuring ongoing accurate instrument and reagent performance, calibration is something many clinical laboratories need to give more resources, attention, and thought to.

Effective calibration gives laboratory analyzers a baseline from which accurate results can be produced. Labs run calibrators (standards) with known values which establish an instrument baseline. The instrument uses this baseline to adjust readings to match the computed value, and from this point accurate results are reported.

However, calibration can be a double-edged sword. Ms. Kee stressed that the quality of the calibrator material directly underpins the successfulness of the calibration. “Consider the situation where the calibrator’s assigned values are inaccurate or the matrix of the calibrator is different to that of a patient sample. Calibration will establish an incorrect instrument baseline, meaning subsequent patient results will be inaccurate,” said Ms. Kee.

To ensure that any given instrument is establishing a reliable baseline and that the laboratory builds and maintains a strong foundation for accurate patient results, Ms. Kee encourages frequent recalibration and closely following instrument and reagent manufacturers' instructions. She also recommended incorporation of the following practices: to use a third-party calibrator, with independently assigned values, and that it is not optimized to work with any specific instrument or reagent system. To use a calibrator with the same (or close as possible) matrix as the patient sample, e.g., when calibrating tests used for urinalysis ensure that a urine-based calibrator is selected. Wherever possible, choose calibrators that are made from 100% human material—particularly important in antibody-based tests, and wherever possible, use a multianalyte calibrator with a long shelf-life to save time, money, labor, and materials.

Related Links:

Randox Laboratories


Platinum Member
COVID-19 Rapid Test
OSOM COVID-19 Antigen Rapid Test
Magnetic Bead Separation Modules
MAG and HEATMAG
Anti-Cyclic Citrullinated Peptide Test
GPP-100 Anti-CCP Kit
New
Gold Member
TORCH Panel Rapid Test
Rapid TORCH Panel Test

Print article

Channels

Clinical Chemistry

view channel
Image: The 3D printed miniature ionizer is a key component of a mass spectrometer (Photo courtesy of MIT)

3D Printed Point-Of-Care Mass Spectrometer Outperforms State-Of-The-Art Models

Mass spectrometry is a precise technique for identifying the chemical components of a sample and has significant potential for monitoring chronic illness health states, such as measuring hormone levels... Read more

Hematology

view channel
Image: The CAPILLARYS 3 DBS devices have received U.S. FDA 510(k) clearance (Photo courtesy of Sebia)

Next Generation Instrument Screens for Hemoglobin Disorders in Newborns

Hemoglobinopathies, the most widespread inherited conditions globally, affect about 7% of the population as carriers, with 2.7% of newborns being born with these conditions. The spectrum of clinical manifestations... Read more

Immunology

view channel
Image: The AI predictive model identifies the most potent cancer killing immune cells for use in immunotherapies (Photo courtesy of Shutterstock)

AI Predicts Tumor-Killing Cells with High Accuracy

Cellular immunotherapy involves extracting immune cells from a patient's tumor, potentially enhancing their cancer-fighting capabilities through engineering, and then expanding and reintroducing them into the body.... Read more

Microbiology

view channel
Image: The T-SPOT.TB test is now paired with the Auto-Pure 2400 liquid handling platform for accurate TB testing (Photo courtesy of Shutterstock)

Integrated Solution Ushers New Era of Automated Tuberculosis Testing

Tuberculosis (TB) is responsible for 1.3 million deaths every year, positioning it as one of the top killers globally due to a single infectious agent. In 2022, around 10.6 million people were diagnosed... Read more