Point-of-Care Device Compared for Cardiac Troponin Assay

By LabMedica International staff writers
Posted on 02 Oct 2013
Print article
Image: The i-STAT portable clinical analyzer system (Photo courtesy of Abbot Laboratories).
Image: The i-STAT portable clinical analyzer system (Photo courtesy of Abbot Laboratories).
A fingerstick point-of-care (POC) testing for cardiac troponin I has been compared to conventional venipuncture POC testing.

Cardiac troponin assays commonly exceed one hour while point-of-care testing can be completed in minutes by basic life support personnel so when patients present complaining of chest pain, time can be critical to achieving positive outcomes.

Scientists at the Loyola University Medical Center (Maywood, IL, USA) collected fingerstick blood samples from consenting patients for whom standard-of-care venipuncture POC troponin (POCT) testing had been ordered as part of their workup. Cardiac troponin (cTnl) assays were performed using a commercial device from June to August 2011. Eighty-nine cTnI levels were measured by both fingerstick and standard venipuncture emergency department POC testing. Four resulted in cartridge error so only the remaining 85 were analyzed.

Cardiac troponin I (cTnI) assays were performed using an i-STAT 1 device (Abbott Point of Care; Princeton, NJ, USA). Fingerstick testing, compared with standard ED POCT, has a positive predictive value of 1.00 (0.48, 1.00), a negative predictive value of 0.96 (0.89, 0.99), a sensitivity of 0.625 (0.24, 0.91), and a specificity of 1.00 (0.95, 1.00). The relationship between methods appeared to be linear.

The authors concluded that fingerstick cTnI testing using the i-STAT device is not accurate enough to determine the exact troponin level without the application of a corrective term. Fingerstick testing is, however, accurate in qualifying troponin levels as negative, borderline, or positive and is, therefore, capable of providing clinical information that may guide diagnostic and therapeutic decision-making. The study was published in the August 2013 issue of the American Journal of Emergency Medicine.

Related Links:
Loyola University Medical Center
Abbott Point of Care


Platinum Member
COVID-19 Rapid Test
OSOM COVID-19 Antigen Rapid Test
Magnetic Bead Separation Modules
MAG and HEATMAG
POCT Fluorescent Immunoassay Analyzer
FIA Go
New
Gold Member
Fully Automated Cell Density/Viability Analyzer
BioProfile FAST CDV

Print article

Channels

Hematology

view channel
Image: The CAPILLARYS 3 DBS devices have received U.S. FDA 510(k) clearance (Photo courtesy of Sebia)

Next Generation Instrument Screens for Hemoglobin Disorders in Newborns

Hemoglobinopathies, the most widespread inherited conditions globally, affect about 7% of the population as carriers, with 2.7% of newborns being born with these conditions. The spectrum of clinical manifestations... Read more

Immunology

view channel
Image: The AI predictive model identifies the most potent cancer killing immune cells for use in immunotherapies (Photo courtesy of Shutterstock)

AI Predicts Tumor-Killing Cells with High Accuracy

Cellular immunotherapy involves extracting immune cells from a patient's tumor, potentially enhancing their cancer-fighting capabilities through engineering, and then expanding and reintroducing them into the body.... Read more

Microbiology

view channel
Image: The T-SPOT.TB test is now paired with the Auto-Pure 2400 liquid handling platform for accurate TB testing (Photo courtesy of Shutterstock)

Integrated Solution Ushers New Era of Automated Tuberculosis Testing

Tuberculosis (TB) is responsible for 1.3 million deaths every year, positioning it as one of the top killers globally due to a single infectious agent. In 2022, around 10.6 million people were diagnosed... Read more